INSPECTIONS
PREPARE 2/11/10, 16:10:52 INSPECTION TICKET PAGE 1
Harn_t ounty INSPECTOR: IVR DATE 2/12/10
- - - - - - -
ADDRESS . : LAND FILE ISSUE SUBDIV:
CONTRACTOR : ADVANCED ELECTRICAL SOLUTIONS' PHONE : (910) 426-2335
OWNER : BENSON DAVID L PHONE :
PARCEL - - - - - - -
APPL NUMBER: 10-50023783 CP STANDALONE TRADE - RESIDENTIAL
DIRECTIONS : T/S: 02/11/2010 04:00 PM VBROWN
25 DOMINION COURT CAMERON 28326.
RICHMOND PARK SUB DIV #487 27W, LEFT ON
BUFFAOL LAKE RD, 875, PLANTATION DRIVE
2ND RIGHT ON DOMINION. CONTRACTOR SAYS
JUNCTION BOX IS UNDER CRAWL SPACE. GO
THROUGH CRAWL SPACE TAKE LEFT. OR GIVE
CONTRACTOR A CALL BRIAN 910 723 3293.
STRUCTURE: 000 000 REPLACE JUNCTION BOX
FLOOD ZONE . . . . : FLOOD ZONE X
PROPOSED USE . . . . . . . : ELECT WATER SUPPLY . . . . . . . : UNKNOWN
PERMIT: CPER 00 CP ELECTRICAL RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
R131 01 2/12/10 TI ONE TRADE FINAL TIME: 17:00 VRU 001882646
2 2 T/S: 02/11/2010 04:09 PM VBROWN
FIRE DAMAGE. FIRE DEPT HAD EL METER PULLED. ELECTRICIAN
CAME IN AND PURCHASED FOR A JUNCTION BOX.
COMMENTS AND NOTES - -
HARNETT COUNTY
Building Inspections Dept.
108 E. Front St.
Lillington, NC 27546
910-893-7525
DO NOT REMOVE
DATE: 02-12-10
PERMIT # 09-50023783
ADDRESS: 25 Dominion
VIOLATIONS:
1. Service ok to reconnect.
2. Splice done on AC feeder under house is not per code.
3. You cannot use a copper split-bolt connector on aluminum
4. You must bond the splice box to ground wire
5. Repair this and call for a reinspection
Harnett County Building Department
Mike Rearic cell# (910) 984- 4772
PREPARED 2/22/10, 13:59:03 - INSPECTION TICKET YPAGE 17
Harnett County INSPECTOR: IVR DATE 2/23/10
ADDRESS . : LAND FILE ISSUE SUBDIV:
CONTRACTOR ADVANCED ELECTRICAL SOLUTIONS PHONE : (910) 426-2335
OWNER BENSON DAVID L & SUN Y PHONE :
PARCEL - - - - - - -
APPL NUMBER: 10-50023783 CP STANDALONE TRADE - RESIDENTIAL
DIRECTIONS : T/S: 02/11/2010 04:00 PM VBROWN
25 DOMINION COURT CAMERON 28326.
RICHMOND PARK SUB DIV #487 27W, LEFT ON
BUFFAOL LAKE RD, 875, PLANTATION DRIVE rte:'
2ND RIGHT ON DOMINION. CONTRACTOR SAYS
JUNCTION BOX IS UNDER CRAWL SPACE. GO
THROUGH CRAWL SPACE TAKE LEFT. OR GIVE
CONTRACTOR A CALL BRIAN 910 723 3293.
STRUCTURE: 000 000 REPLACE JUNCTION BOX (FIRE DAMAGE)
FLOOD ZONE . . . . : FLOOD ZONE X
PROPOSED USE . . . . . . . : ELECT WATER SUPPLY . . . . . . . : UNKNOWN
PERMIT: CPER 00 CP ELECTRICAL RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - - -
R131 01 2/12/10 ONE TRADE FINAL TIME: 17:00 VRU 001882646
2/12/10 DA T/S: 02/11/2010 04:09 PM VBROWN
FIRE DAMAGE. FIRE DEPT HAD EL METER PULLED. ELECTRICIAN
CAME IN AND PURCHASED FOR A JUNCTION BOX.
T/S: 02/12/2010 10:46 AM MREARIC
Service ok to reconnect
1. splice does not meet code.
aluminum grounds have been connected with a copper
split-bolt connector
2. splice box is not bonded to ground wire
3. repair the repair and call for re inspection
T/S: 02/22/2010 11:16 AM NTART
R131 02 2/23/10 /j ONE TRADE FINAL VRU 001886001
----------/J~-------'---~d-----\- COMMENTS AND NOTES
s s s
a`~ (Nrr 'iii N A e e
COUNTY OF HARNETT
e.
DEPARTMENT OF BUILDING INSPECTION
AND PLANNING/DEVELOPMENT
CERTIFICATE OF COMPLIANCE
This certificate issued pursuant to the requirements of Section 307of the North Carolina Administration ; Miff
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in
compliance with the various ordinances of the County of Harnett regulating development and building,
construction or use. For the following: SE' r v c
Use Classification: Q 3 Conditional Use Permit No.:
7 Type of Construction: Building PefmttNo.' -C/7A '2 '3 -7.117 3
Owner of Building: Be to rr- &A _ lectrical Permit No.:
Building Address: Z., S 0t7 t~ tow C4 Insulation Permit No.:
Zoning District: Plumbing Permit No.:
Zoning Permit No.: Mech. Permit No.:
Date: Envir C.O. No.:
Building Official Zoning Official
W~ 'vy~Yl` "ip~ ~rq fi" icy 05#"
l ` hJ 1 c
1 !''g ~ "~I ~ l1M' u~ ~o ~l 0 '~>)l ll~a ~ l~ ~ Ul` < z, ~1