INSPECTIONS
PREPARED 9/21/09, 14:38:36 INSPECTION TICKET PAGE 49
Harnett County INSPECTOR: IVR DATE 9/22/09
i-"`-""------"'---""'------""'-------------------------------------------------
ADDRESS . :.11435 NC 27 W SUBDIV:
CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129
OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE
11435 NC 27 WEST.
TAKE HWY 27WEST, GO PAST WESTERN
HARNETT MIDDLE SCHOOL. HOME IS THE 1ST
WHITE HOUSE ON THE LEFT.
STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING
WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
-111 01 9/22/09 TI / R*BLDG SLAB INSP VRU 001824960
P309 01 9/22/09 TI R*PLUMB UNDER SLAB VRU 001824952 ,
e-MP-N
- COMMENTS AND NOTES - -
HARNETT COUNTY
Building Inspections Dept.
108 E. Front St.
L.illington, NC 27546
910-893-7525
DO NOT REMOVE
DATE: 09-22-09
PERMIT # 09-50022665
ADDRESS: 11435 nc 27 w
VIOLATIONS:
1. Bottom of slab footer must be 12" below undisturbed grade
R403.1.(1))and the siding and wall framing must be 6 " above grade
(figure notes R319.5), therefore the minimum thickness of the slab
footer will be 18"
2. The plastic must be below the steel in the footer and must be in place
for slab inspection
3. All you can get at this time is the underground plumbing
~ s
Hamett County Building Department
Mike Rearic cell# (910) 984- 4772
F7PREPARED 9/24/09, 14:07:23 INSPECTION TICKET PAGE 22
Harnett County INSPECTOR: IVR DATE 9/25/09
ADDRESS . : 11435 NC 27 W SUBDIV:
CONTRACTOR : M & R ASSOCIATES PHONE (919) 776-0129
OWNER : STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL : 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE
11435 NC 27 WEST.
TAKE HWY 27WEST, GO PAST WESTERN
HARNETT MIDDLE SCHOOL. HOME IS THE 1ST
WHITE HOUSE ON THE LEFT.
i
STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BURN
FLOOD ZONE FLOOD ZONE X
# BEDROOMS .00 SEPTIC - EXISTING? . . . . : EXISTING
WATER SUPPLY . . . . . . . COUNTY
e
l PERMIT- CPBP 00 CP BUILDING PERMIT-'`
REQUESTED-;I INSP`~ DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
B111.O1 9/22/09 MR R*BLDG SLAB INSP VRU 001824960
9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC
T IS: 09/22/2009 12:08 PM MREARIC
1. bottom of footer must be 12" below natural grade
2. wall siding must be 6" above grade so, footer must be 18"
min. deep
3. plastic must be installed below the steel
4. insulation must be installed at perimeter
P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952
9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC
nail guards
T/S: 09/22/2009 12:10 PM MREARIC
B111 02 ~9,/2.~5/~09q TI R*BLDG SLAB ep -VRU #:-00182727
-(y If possible,~P~lea-s4inspect_ua_the,= mor*++- atiie t anuNhe
ternoom.:-If you have any_guestiona please call Ryan"~
953-0'9DV-Thank You.
- - COMMENTS AND NOTES
PREPARED 11/05/09, 13:58:55 INSPECTION TICKET PAGE 27
Harnett County INSPECTOR: IVR DATE 11/06/09
ADDRESS . : 11435 NC 27 W SUBDIV:
CONTRACTOR M& R ASSOCIATES PHONE (919) 776-0129
OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE
11435 NC 27 WEST.
TAKE HWY 27WEST, GO PAST WESTERN
HARNETT MIDDLE SCHOOL. HOME IS THE 1ST
WHITE HOUSE ON THE LEFT.
STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING
WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
13111 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960
9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC
T/S: 09/22/2009 12:08 PM MREARIC
1. bottom of footer must be 12" below natural grade
2. wall siding must be 6" above grade so, footer must be 18"
min. deep
3. plastic must be installed below the steel
4. insulation must be installed at perimeter
P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952
9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC
nail guards
T/S: 09/22/2009 12:10 PM MREARIC
B111 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827278
9/25/09 AP If possible, Please inspect in the morning rather than the
afternoon. If you have any questions please call Ryan W
919-353-0907. Thank You.
T/S: 09/25/2009 11:26 AM MREARIC
R425 01 11/05/09 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492
T/S: 11/04/2009 11:57 AM VBROWN
INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS
HOUSE.
T/S: 11/04/2009 01:58 PM NTART
PLEASE GO IN THE AFTERNOON
E217 01 11/06/09 TI R*ELEC RECONNECT VRU 001846831
CjP-+.(R It is a Meter base Inspection on outside of house for
-T- transfer of power.
We had to remove meter base where addition was added to
house and placed new meter base on outside of house.
If you have any questions please call RYAN @ 919-353-0907.
COMMENTS AND NOTES
PREPARED 11/10/09, 14:01:13 INSPECTION TICKET PAGE 24 O'
Harnett County INSPECTOR: IVR DATE 11/12/09
ADDRESS . : 11435 NC 27 W SUBDIV:
CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129
OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE
11435 NC 27 WEST.
TAKE HWY 27WEST, GO PAST WESTERN
HARNETT MIDDLE SCHOOL. HOME IS THE 1ST
WHITE HOUSE ON THE LEFT.
T/S: 11/10/2009 10:38 AM VBROWN l'
PREMIS NUMBER 54293553.
STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE DORM C1
FLOOD ZONE . . . . : FLOOD ZONE X f
# BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING
WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
Bill 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960
9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC
T/S: 09/22/2009 12:08 PM MREARIC
1. bottom of footer must be 12" below natural grade
2. wall siding must be 6" above grade so, footer must be 18"
min. deep
3. plastic must be installed below the steel
4. insulation must be installed at perimeter
P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952
9122109 AP T/S: 09/22/2009 12:04 PM MREARIC
nail guards
T/S: 09/22/2009 12:10 PM MREARIC
Bill 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827278
9/25/09 AP If possible, Please inspect in the morning rather than the
afternoon. If you have any questions please call Ryan @
919-353-0907. Thank You.
T/S: 09/25/2009 11:26 AM MREARIC
R425 01 11105109 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492
11/06/09 AP T/S: 11/04/2009 11:57 AM VBROWN
INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS
HOUSE.
T/S: 11/04/2009 01:58 PM NTART
PLEASE GO IN THE AFTERNOON
T/S: 11/06/2009 12:43 PM MREARIC
E217 01 11106109 MR R*ELEC RECONNECT VRU 001846831
11106109 AP It is a Meter base Inspection on outside of house for
transfer of power.
We had to remove meter base where addition was added to
house and placed new meter base on outside of house.
If you have any questions please call RYAN @ 919-353-0907.
T/S: 11/06/2009 12:44 PM MREARIC
meter is ready for changeover... no one living in home
1129 01 11/12/09 TI R*INSULATION INSPECTION VRU 001846753
Alp- 610-
COMMENTS AND NOTES
PREPARED 2/02/10, 13:56:39 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 2/03/10
ADDRESS 11435 NC 27 W SUBDIV:
CONTRACTOR P~,& R ASSOCIATES PHONE (919) 776-0129
OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE
11435 NC 27 WEST.
TAKE HWY 27WEST, GO PAST WESTERN
HARNETT MIDDLE SCHOOL. HOME IS THE 1ST
WHITE HOUSE ON THE LEFT.
T/S: 11/10/2009 10:38 AM VBROWN
PREMIS NUMBER 54293553.
STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING
WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B111 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960
9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC
T/S: 09/22/2009 12:08 PM MREARIC
1. bottom of footer must be 12" below natural grade
2. wall siding must be 6" above grade so, footer must be 18"
min. deep
3. plastic must be installed below the steel
4. insulation must be installed at perimeter
P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952
9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC
nail guards
T/S: 09/22/2009 12:10 PM MREARIC
Bill 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827278
9/25/09 AP If possible, Please inspect in the morning rather than the
afternoon. If you have any questions please call Ryan @
919-353-0907. Thank You.
T/S: 09/25/2009 11:26 AM MREARIC
R425 01 11/05/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492
11/06/09 AP T/S:- 11/04/2009 11:57 AM VBROWN
INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS
HOUSE.
T/S: 11/04/2009 01:56 PM NTART
PLEASE GO IN THE AFTERNOON
T/S: 11/06/2009 12:43 PM MREARIC
E217 01 11/06/09 MR R*ELEC RECONNECT VRU 001846831
11/06/09 AP It is a Meter base Inspection on outside of house for
transfer of power.
We had to remove meter base where addition was added to
house and placed new meter base on outside of house.
If you have any questions please call RYAN @ 919-353-0907.
T/S: 11/06/2009 12:44 PM MREARIC
meter is ready for changeover... no one living in home
1129 01 11/12/09 MR R*INSULATION INSPECTION VRU 001848753
11/12/09 AP T/S: 11/12/2009 11:53 AM MREARIC
CONTINUED ONTO NEXT PAGE -
PREPARED 2/02/10, 13:58:39 INSPECTION TICKET PAGE 11
Harnett County INSPECTOR: IVR DATE 2/03/10
ADDRESS . : 11435 NC 27 W SUBDIV:
CONTRACTOR N1,.& R ASSOCIATES PHONE (919) 776-0129
OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
R429 01 2/03/10 IT FOUR TRADE FINAL VRU 001876925
Z • 3 c~ -KI~=~~
COMMENTS AND NOTES
HARNETT COUNTY
Building Inspections Dept.
108 E. Front St.
Lillington, NC 27546
910-893-7525
DO NOT REMOVE
DATE: 02-03-10
PERMIT # 09-50022665
ADDRESS: 11435 NC 27 W
VIOLATIONS:
1. Smoke detectors must be installed, one inside the bedroom and one
outside the bedroom door
2. Could not inspect the panel, it was wet with paint
3. Bond existing metal water piping per code and provide an intersystem
bonding terminal
Harnett County Building Department
Mike Rearic cell# (910) 984- 4772
PREPARED 2/04/10, 13:58:46 INSPECTION TICKET PAGE 9
Harnett County INSPECTOR: IVR DATE 2/05/10
- - - - -
ADDRESS :711435 NC 27 W SUBDIV:
CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129
OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE
11435 NC 27 WEST.
TAKE HWY 27WEST, GO PAST WESTERN
HARNETT MIDDLE SCHOOL. HOME IS THE 1ST
WHITE HOUSE ON THE LEFT.
T/S: 11/10/2009 10:38 AM VBROWN
PREMIS NUMBER 54293553.
STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING
WATER SUPPLY . . . . . . . : COUNTY
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
B111 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960
9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC
T/S: 09/22/2009 12:08 PM MREARIC
1. bottom of footer must be 12" below natural grade
2. wall siding must be 6" above grade so, footer must be 18"
min. deep
3. plastic must be installed below the steel
4. insulation must be installed at perimeter
P309,01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952
9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC
nail guards
T/S: 09/22/2009 12:10 PM MREARIC
Bill 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827276
9/25/09 AP If possible, Please inspect in the morning rather than the
afternoon. If you have any questions please call Ryan
919-353-0907. Thank You.
T/S: 09/25/2009 11:26 AM MREARIC
R425 01 11/05/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492
11/06/09 AP T/S: 11/04/2009 11:57 AM VBROWN
INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS
HOUSE.
T/S: 11/04/2009 01:58 PM NTART
PLEASE GO IN THE AFTERNOON
T/S: 11/06/2009 12:43 PM MREARIC
E217 01 11106109 MR R*ELEC RECONNECT VRU 001846831 -
11/06/09 AP It is a Meter base Inspection on outside of house for
transfer of power.
We had to remove meter base where addition was added to
house and placed new meter base on outside of house.
If you have any questions please call RYAN @ 919-353-0907.
T/S: 11/06/2009 12:44 PM MREARIC
meter is ready for changeover... no one living in home
1129 01 11/12/09 _ MR R*INSULATION INSPECTION VRU 001848753
11/12/09 AP T/S: 11/12/2009 11-:53 AM MREARIC
CONTINUED ONTO NEXT PAGE - -
PREPARED 2/04/10, 13:56:46 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 2/05/10
- - -
ADDRESS :711431 NC 27 W SUBDIV:
CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129
OWNER :STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892
PARCEL 03-0507- - -0038- -01-
APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - -
R429 01 2/03/10 FOUR TRADE FINAL VRU 001878925
2/03/10 DP T/S: 02/03/2010 12:35 PM MREARIC
1. smoke detectors needed on each side of bedroom door
2. could not inspect panel it was wet with paint
3. bond existing water pipe and install an intersystem
bonding terminal
T/S: 02/03/2010 02:19 PM NTART
R429 02 2/05/10 TI FOUR TRADE FINAL TIME: 17:00 VRU 001879600
7 -5-J0 AP_A~R_ T/S: 02/03/2010 02:29 PM NTART
- - COMMENTS AND NOTES
..`.G:%~y c,-'-~.; 'a t...}y. :^r l rv--Cy~S`v.t .....r r ,r :,i` 14..-..r,'rnt. w3"f.N"a"ri jef` f"1„RP~~ N':"'ti~'q +~/i.~•r rv t:,mele'r_a{~+1° st,`5~...,;;.
>
COUNTY OF HARNETT
DEPARTMENT OF BUILDING INSPECTION
q, AND PLANNING/DEVELOPMENT
CERTIFICATE OF OCCUPANCY
This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building;
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in
compliance with the various ordinances of the Count of Harnett regulating development and building
construction or use. For the following: /Qcr1 rJ rYt o H
Use Classification: Z-3 Conditional Use Permit No.:
Type of Construction: Building Permit No.: -s-r~n Z2G65
Owner of Building: S of, r Electrical Permit No.: If I
k~ Building Address: 2. Insulation Permit No.: f r
§ Zoning District: Plumbing Permit No.: (I
Zoning Permit No.: Mech. Permit No.:
Date: Envir. C.O. No.:
el-'AL ~p•a,
Building Official Zoning Official
5 ~ '