Loading...
INSPECTIONS PREPARED 9/21/09, 14:38:36 INSPECTION TICKET PAGE 49 Harnett County INSPECTOR: IVR DATE 9/22/09 i-"`-""------"'---""'------""'------------------------------------------------- ADDRESS . :.11435 NC 27 W SUBDIV: CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129 OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE 11435 NC 27 WEST. TAKE HWY 27WEST, GO PAST WESTERN HARNETT MIDDLE SCHOOL. HOME IS THE 1ST WHITE HOUSE ON THE LEFT. STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - -111 01 9/22/09 TI / R*BLDG SLAB INSP VRU 001824960 P309 01 9/22/09 TI R*PLUMB UNDER SLAB VRU 001824952 , e-MP-N - COMMENTS AND NOTES - - HARNETT COUNTY Building Inspections Dept. 108 E. Front St. L.illington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 09-22-09 PERMIT # 09-50022665 ADDRESS: 11435 nc 27 w VIOLATIONS: 1. Bottom of slab footer must be 12" below undisturbed grade R403.1.(1))and the siding and wall framing must be 6 " above grade (figure notes R319.5), therefore the minimum thickness of the slab footer will be 18" 2. The plastic must be below the steel in the footer and must be in place for slab inspection 3. All you can get at this time is the underground plumbing ~ s Hamett County Building Department Mike Rearic cell# (910) 984- 4772 F7PREPARED 9/24/09, 14:07:23 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 9/25/09 ADDRESS . : 11435 NC 27 W SUBDIV: CONTRACTOR : M & R ASSOCIATES PHONE (919) 776-0129 OWNER : STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL : 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE 11435 NC 27 WEST. TAKE HWY 27WEST, GO PAST WESTERN HARNETT MIDDLE SCHOOL. HOME IS THE 1ST WHITE HOUSE ON THE LEFT. i STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BURN FLOOD ZONE FLOOD ZONE X # BEDROOMS .00 SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY e l PERMIT- CPBP 00 CP BUILDING PERMIT-'` REQUESTED-;I INSP`~ DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - B111.O1 9/22/09 MR R*BLDG SLAB INSP VRU 001824960 9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC T IS: 09/22/2009 12:08 PM MREARIC 1. bottom of footer must be 12" below natural grade 2. wall siding must be 6" above grade so, footer must be 18" min. deep 3. plastic must be installed below the steel 4. insulation must be installed at perimeter P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952 9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC nail guards T/S: 09/22/2009 12:10 PM MREARIC B111 02 ~9,/2.~5/~09q TI R*BLDG SLAB ep -VRU #:-00182727 -(y If possible,~P~lea-s4inspect_ua_the,= mor*++- atiie t anuNhe ternoom.:-If you have any_guestiona please call Ryan"~ 953-0'9DV-Thank You. - - COMMENTS AND NOTES PREPARED 11/05/09, 13:58:55 INSPECTION TICKET PAGE 27 Harnett County INSPECTOR: IVR DATE 11/06/09 ADDRESS . : 11435 NC 27 W SUBDIV: CONTRACTOR M& R ASSOCIATES PHONE (919) 776-0129 OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE 11435 NC 27 WEST. TAKE HWY 27WEST, GO PAST WESTERN HARNETT MIDDLE SCHOOL. HOME IS THE 1ST WHITE HOUSE ON THE LEFT. STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 13111 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960 9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC T/S: 09/22/2009 12:08 PM MREARIC 1. bottom of footer must be 12" below natural grade 2. wall siding must be 6" above grade so, footer must be 18" min. deep 3. plastic must be installed below the steel 4. insulation must be installed at perimeter P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952 9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC nail guards T/S: 09/22/2009 12:10 PM MREARIC B111 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827278 9/25/09 AP If possible, Please inspect in the morning rather than the afternoon. If you have any questions please call Ryan W 919-353-0907. Thank You. T/S: 09/25/2009 11:26 AM MREARIC R425 01 11/05/09 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492 T/S: 11/04/2009 11:57 AM VBROWN INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS HOUSE. T/S: 11/04/2009 01:58 PM NTART PLEASE GO IN THE AFTERNOON E217 01 11/06/09 TI R*ELEC RECONNECT VRU 001846831 CjP-+.(R It is a Meter base Inspection on outside of house for -T- transfer of power. We had to remove meter base where addition was added to house and placed new meter base on outside of house. If you have any questions please call RYAN @ 919-353-0907. COMMENTS AND NOTES PREPARED 11/10/09, 14:01:13 INSPECTION TICKET PAGE 24 O' Harnett County INSPECTOR: IVR DATE 11/12/09 ADDRESS . : 11435 NC 27 W SUBDIV: CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129 OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE 11435 NC 27 WEST. TAKE HWY 27WEST, GO PAST WESTERN HARNETT MIDDLE SCHOOL. HOME IS THE 1ST WHITE HOUSE ON THE LEFT. T/S: 11/10/2009 10:38 AM VBROWN l' PREMIS NUMBER 54293553. STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE DORM C1 FLOOD ZONE . . . . : FLOOD ZONE X f # BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - Bill 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960 9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC T/S: 09/22/2009 12:08 PM MREARIC 1. bottom of footer must be 12" below natural grade 2. wall siding must be 6" above grade so, footer must be 18" min. deep 3. plastic must be installed below the steel 4. insulation must be installed at perimeter P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952 9122109 AP T/S: 09/22/2009 12:04 PM MREARIC nail guards T/S: 09/22/2009 12:10 PM MREARIC Bill 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827278 9/25/09 AP If possible, Please inspect in the morning rather than the afternoon. If you have any questions please call Ryan @ 919-353-0907. Thank You. T/S: 09/25/2009 11:26 AM MREARIC R425 01 11105109 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492 11/06/09 AP T/S: 11/04/2009 11:57 AM VBROWN INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS HOUSE. T/S: 11/04/2009 01:58 PM NTART PLEASE GO IN THE AFTERNOON T/S: 11/06/2009 12:43 PM MREARIC E217 01 11106109 MR R*ELEC RECONNECT VRU 001846831 11106109 AP It is a Meter base Inspection on outside of house for transfer of power. We had to remove meter base where addition was added to house and placed new meter base on outside of house. If you have any questions please call RYAN @ 919-353-0907. T/S: 11/06/2009 12:44 PM MREARIC meter is ready for changeover... no one living in home 1129 01 11/12/09 TI R*INSULATION INSPECTION VRU 001846753 Alp- 610- COMMENTS AND NOTES PREPARED 2/02/10, 13:56:39 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 2/03/10 ADDRESS 11435 NC 27 W SUBDIV: CONTRACTOR P~,& R ASSOCIATES PHONE (919) 776-0129 OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE 11435 NC 27 WEST. TAKE HWY 27WEST, GO PAST WESTERN HARNETT MIDDLE SCHOOL. HOME IS THE 1ST WHITE HOUSE ON THE LEFT. T/S: 11/10/2009 10:38 AM VBROWN PREMIS NUMBER 54293553. STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B111 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960 9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC T/S: 09/22/2009 12:08 PM MREARIC 1. bottom of footer must be 12" below natural grade 2. wall siding must be 6" above grade so, footer must be 18" min. deep 3. plastic must be installed below the steel 4. insulation must be installed at perimeter P309 01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952 9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC nail guards T/S: 09/22/2009 12:10 PM MREARIC Bill 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827278 9/25/09 AP If possible, Please inspect in the morning rather than the afternoon. If you have any questions please call Ryan @ 919-353-0907. Thank You. T/S: 09/25/2009 11:26 AM MREARIC R425 01 11/05/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492 11/06/09 AP T/S:- 11/04/2009 11:57 AM VBROWN INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS HOUSE. T/S: 11/04/2009 01:56 PM NTART PLEASE GO IN THE AFTERNOON T/S: 11/06/2009 12:43 PM MREARIC E217 01 11/06/09 MR R*ELEC RECONNECT VRU 001846831 11/06/09 AP It is a Meter base Inspection on outside of house for transfer of power. We had to remove meter base where addition was added to house and placed new meter base on outside of house. If you have any questions please call RYAN @ 919-353-0907. T/S: 11/06/2009 12:44 PM MREARIC meter is ready for changeover... no one living in home 1129 01 11/12/09 MR R*INSULATION INSPECTION VRU 001848753 11/12/09 AP T/S: 11/12/2009 11:53 AM MREARIC CONTINUED ONTO NEXT PAGE - PREPARED 2/02/10, 13:58:39 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 2/03/10 ADDRESS . : 11435 NC 27 W SUBDIV: CONTRACTOR N1,.& R ASSOCIATES PHONE (919) 776-0129 OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R429 01 2/03/10 IT FOUR TRADE FINAL VRU 001876925 Z • 3 c~ -KI~=~~ COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 02-03-10 PERMIT # 09-50022665 ADDRESS: 11435 NC 27 W VIOLATIONS: 1. Smoke detectors must be installed, one inside the bedroom and one outside the bedroom door 2. Could not inspect the panel, it was wet with paint 3. Bond existing metal water piping per code and provide an intersystem bonding terminal Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 2/04/10, 13:58:46 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 2/05/10 - - - - - ADDRESS :711435 NC 27 W SUBDIV: CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129 OWNER STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL DIRECTIONS : T/S: 08/17/2009 10:35 AM RDCONTE 11435 NC 27 WEST. TAKE HWY 27WEST, GO PAST WESTERN HARNETT MIDDLE SCHOOL. HOME IS THE 1ST WHITE HOUSE ON THE LEFT. T/S: 11/10/2009 10:38 AM VBROWN PREMIS NUMBER 54293553. STRUCTURE: 000 000 20X21 ENCLOSE CARPORT TO MAKE BDRM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . .00 SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B111 01 9/22/09 MR R*BLDG SLAB INSP VRU 001824960 9/22/09 DA T/S: 09/22/2009 12:03 PM MREARIC T/S: 09/22/2009 12:08 PM MREARIC 1. bottom of footer must be 12" below natural grade 2. wall siding must be 6" above grade so, footer must be 18" min. deep 3. plastic must be installed below the steel 4. insulation must be installed at perimeter P309,01 9/22/09 MR R*PLUMB UNDER SLAB VRU 001824952 9/22/09 AP T/S: 09/22/2009 12:04 PM MREARIC nail guards T/S: 09/22/2009 12:10 PM MREARIC Bill 02 9/25/09 MR R*BLDG SLAB INSP VRU 001827276 9/25/09 AP If possible, Please inspect in the morning rather than the afternoon. If you have any questions please call Ryan 919-353-0907. Thank You. T/S: 09/25/2009 11:26 AM MREARIC R425 01 11/05/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001846492 11/06/09 AP T/S: 11/04/2009 11:57 AM VBROWN INSPECTOR WILL NEED TO WALK IN BACK OF ADDITION TO ACCESS HOUSE. T/S: 11/04/2009 01:58 PM NTART PLEASE GO IN THE AFTERNOON T/S: 11/06/2009 12:43 PM MREARIC E217 01 11106109 MR R*ELEC RECONNECT VRU 001846831 - 11/06/09 AP It is a Meter base Inspection on outside of house for transfer of power. We had to remove meter base where addition was added to house and placed new meter base on outside of house. If you have any questions please call RYAN @ 919-353-0907. T/S: 11/06/2009 12:44 PM MREARIC meter is ready for changeover... no one living in home 1129 01 11/12/09 _ MR R*INSULATION INSPECTION VRU 001848753 11/12/09 AP T/S: 11/12/2009 11-:53 AM MREARIC CONTINUED ONTO NEXT PAGE - - PREPARED 2/04/10, 13:56:46 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 2/05/10 - - - ADDRESS :711431 NC 27 W SUBDIV: CONTRACTOR M & R ASSOCIATES PHONE (919) 776-0129 OWNER :STONE ROBERT WAYNE & KAREN PHONE (910) 308-1892 PARCEL 03-0507- - -0038- -01- APPL NUMBER: 09-50022665 CP ADD & ALTER RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - R429 01 2/03/10 FOUR TRADE FINAL VRU 001878925 2/03/10 DP T/S: 02/03/2010 12:35 PM MREARIC 1. smoke detectors needed on each side of bedroom door 2. could not inspect panel it was wet with paint 3. bond existing water pipe and install an intersystem bonding terminal T/S: 02/03/2010 02:19 PM NTART R429 02 2/05/10 TI FOUR TRADE FINAL TIME: 17:00 VRU 001879600 7 -5-J0 AP_A~R_ T/S: 02/03/2010 02:29 PM NTART - - COMMENTS AND NOTES ..`.G:%~y c,-'-~.; 'a t...}y. :^r l rv--Cy~S`v.t .....r r ,r :,i` 14..-..r,'rnt. w3"f.N"a"ri jef` f"1„RP~~ N':"'ti~'q +~/i.~•r rv t:,mele'r_a{~+1° st,`5~...,;;. > COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION q, AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building; Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the Count of Harnett regulating development and building construction or use. For the following: /Qcr1 rJ rYt o H Use Classification: Z-3 Conditional Use Permit No.: Type of Construction: Building Permit No.: -s-r~n Z2G65 Owner of Building: S of, r Electrical Permit No.: If I k~ Building Address: 2. Insulation Permit No.: f r § Zoning District: Plumbing Permit No.: (I Zoning Permit No.: Mech. Permit No.: Date: Envir. C.O. No.: el-'AL ~p•a, Building Official Zoning Official 5 ~ '