Loading...
INSPECTIONS PREPARED 3/09/09, 14:17:28 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 3/10/09 ADDRESS . : *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRATRL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . EXISTING WATER SUPPLY . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 3/10/09 TI n R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 / mss, COMMENTS AND NOTES PREPARED 3/24/09, 13:59:38 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 3/25/09 4 ADDRESS. : 23171 *UNASSIGNED SUBDIV: CONTRACTOR : M J G CONSTRUCTION PHONE (910) 893-5677 OWNER : RU13INOSKY MARGARETE PHONE (919) 499-6766 PARCEL : 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD Q4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.513ATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN IN # BY DRIVE AND ON HOME B103 01 3/25/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3-Z s.9 MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 COMMENTS AND NOTES PREPARED 4/27/09, 13:59:36 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 4/28/09 ADDRESS . : 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN LN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 TI R*OPEN FLOOR TIME: 17:00 VRU 001760396 c/ Esc-9-9 1~f\ -M~ - - - - - COMMENTS AND NOTES c UQObl~s l~Icss«~ PREPARED 4/29/09, 9:28:10 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/29/09 ADDRESS . : 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.513ATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 13101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN IN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 4/29/09 ~ ~q.QR*OPEN FLOOR TIME: 17:00 VRU 001761832 Q D - - COMMENTS AND NOTES PREPARED 5/01/09, 10:45:52 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/29/09 ADDRESS . : 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X - # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN IN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 ~4//2A9//009 TI R*OPEN FLOOR TIME: 17:00 VRU 001761832 - - COMMENTS AND NOTES - A PREPARED, 7/01/09, 13:58:17 INSPECTION TICKET PAGE 9 Harnett-lountY' INSPECTOR: IVR DATE 7/02/09 ADDRESS . : 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN LN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 4/29/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001761832 4/29/09 AP R427 01 7/02/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001789536 7-2_9 f) a-AAZ_ T/S: 07/01/2009 11:49 AM VBROWN - COMMENTS AND NOTES - HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 07-02-09 PERMIT # 09-50021568 ADDRESS: 3 Acorn lane VIOLATIONS: 1. Tyvek must be applied on all exterior surfaces, dormers also 2. Nail guards missing on many plumbing pipes 3. Attic gable walls are balloon framed, top plate in middle must be braced for lateral forces table3 R602.3(1) 4. Washer box must be at 34" above finished floor 5. Large Windows in living room and master closet must be tempered R308.4.6 6. No water in drain pipe for test 7. Toilet flanges must be screwed down with galy screws (2 min.) 8. Support all hips R802.3 9. Support between foyer and living room has been eliminated. Provide engineering to prove the lam beam will hold the load Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 7/10/09, 13:59:17 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 7/13/09 ADDRESS . : 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - -101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN LN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 4/29/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001761832 4/29/09 AP R427 01 7/02/09 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001789536 7/02/09 DA T/S: 07/01/2009 11:49 AM VBROWN T/S: 07/02/2009 03:20 PM MREARIC 1. tyvek on all outside surfaces - 2. plumbing nailguards missing 3. gable ends are not balloon framed. they have a break in the mid-point which must be braced 4. washer box must be 34" above finished floor 5. large windows in master closet and living room when below 18" must be tempered R308.4.6 6. no water in drain pipes for test 7. toilet flanges must be screwed down with galv. or stainless screws 8. support all hips per code 9. support under lam beam at foyer/ living room has been eli minated. provide engineering to prove lamn beam will hold the load R427 02 7/13 _ FOUR TRADE ROUGH IN >2500 VRU 001793041 mike, the temperd windows have been ordered..i believe we have all others on the infractions list fixed. thanks COMMENTS AND NOTES 1-------------- PREPARED 8/10/09, 13:58:50 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 8/11/09 ADDRESS . : 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD @4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP 3 ACORN LN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 4/29/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001761832 4/29/09 AP R427 01 7/02/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001789536 7/02/09 DA T/S: 07/01/2009 11:49 AM VBROWN T/S: 07/02/2009 03:20 PM MREARIC 1. tyvek on all outside surfaces 2. plumbing nailguards missing 3. gable ends are not balloon framed. they have a break in the mid-point which must be braced 4. washer box must be 34" above finished floor 5. large windows in master closet and living room when below 18" must be tempered R308.4.6 6. no water in drain pipes for test 7. toilet flanges must be screwed down with galv. or stainless screws 8. support all hips per code 9. support under lam beam at foyer/ living room has been eli minated. provide engineering to prove lamn beam will hold the load R427 02 7/13/09 FS FOUR TRADE ROUGH IN >2500 VRU 001793041 7/13/09 AP mike, the temperd windows have been ordered. i believe we have all others on the infractions list fixed. thanks T/S: 07/13/2009 01:13 PM FSPIVEY I129 01 8/11/09 TIp R*INSULATION INSPECTION VRU 001806827 AP__lam - - - - COMMENTS AND NOTES r i c (c S,~ i o~ , 1,.7 l(C°l PREPARED 12/17/09, 13:59:22 INSPECTION TICKET PAGE 3 Harnett. Cou3ty INSPECTOR: IVR DATE 12/18/09 - - - - ADDRESS .-l 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD O4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . :VEXISTING WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP ✓ 3 ACORN LN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 4/29/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001761832 4/29/09 AP R427 01 7/02/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001789536 7/02/09 DA T/S: 07/01/2009 11:49 AM VBROWN T/S: 07/02/2009 03:20 PM MREARIC 1. tyvek on all outside surfaces 2. plumbing nailguards missing 3. gable ends are not balloon framed. they have a break in the mid-point which must be braced 4. washer box must be 34" above finished floor 5. large windows in master closet and living room when below 18" must be tempered R308.4.6 6. no water in drain pipes for test 7. toilet flanges must be screwed down with galv. or stainless screws 8. support all hips per code 9. support under lam beam at foyer/ living room has been eli minated. provide engineering to prove lamn beam will hold the load R427 02 7/13/09 FS FOUR TRADE ROUGH IN >2500 VRU 001793041 7/13/09 AP mike, the temperd windows have been ordered. i believe we have all others on the infractions list fixed. thanks T/S: 07/13/2009 01:13 PM FSPIVEY I129 01 8/11/09 TI R*INSULATION INSPECTION VRU 001806827 1 -9 6 (L. - CONTINUED ONTO NEXT PAGE - - - - - - PREPARED 12/17/09, 13:59:22 INSPECTION TICKET PAGE 4 Harnett. County INSPECTOR: IVR DATE 12/18/09 - - ADDRE§S . ~ 23171 *UNASSIGNED SUBDIV: CONTRACTOR M J G CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R431 01 12/18/09 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001863026 (;a - -..T/S: 12/17/2009 10:40 AM VBROWN CUSTOMER REQUEST AFTERNOON INSP. LATE AS POSSIBLE. - COMMENTS AND NOTES - HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 12-18-09 PERMIT # 09-50021568 ADDRESS: 3 acorn lane VIOLATIONS: 1. Install protective bar per code over windows in closet and dining room on both sides where more than 9 sq. ft in area and within 18" of floor 2. Front porch must have a guard railing per code (min. 36" high) 3. Back porch must have a guard railing min. 36" high 4. All steps must have a handrail ...min. 30-38" high ...attic steps also 5. Provide a draft stop at roof line around the fireplace flue, (metal) 6. Provide info on fireplace ...installation instructions 7. Have Insulation co. provide info on all sprayed-in insulation as installed. 8. Provide garage door wind rating 9. Provide floor in front of panel on second floor 10. Remove all wood from roof (2x4's) 11. Paint crawl space door 12. grading around house must go down from house at a rate of 6" in 10' 13. Install front porch steps ...per code 14. Finish all electric 15. Parge all blocks under A/C in crawlspace 16. Install permanent column in dining room under lam beam Call for re-inspection when complete Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 1/29/10, 13:59:28 INSPECTION TICKET PAGE 2 HarneEt-County INSPECTOR: IVR DATE 2/01/10 ADDRESS 23171 *UNASSIGNED SUBDIV: CONTRACTOR M•J'►G_CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL'. 03-9566- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) DIRECTIONS : BUFFALO ESTATES #92. NEAR ACCORN LANE AND PINEWOOD RD. 27W TO BUFFALO LAKE RD, LEFT ON BUFFALO LAKE RD ®4MI, TURN RIGHT ON PINEWOOD STREET AND GO TO THE VERY END OF THE ROAD, PINEWOOD INTERSECTS ACORN STREET, LOT IS DIRECTLY ACROSS THE INTERSECTION. T/S: 02/11/2009 12:08 PM VBROWN STRUCTURE: 000 000 65X76 3BDR 2.5BATH SFD, GAR, DECK, CRAWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . :1~XISTING WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - - - B101 01 3/10/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001741644 3/10/09 AP A814 01 3/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001742162 3/20/09 AP -413 ACORN IN # BY DRIVE AND ON HOME B103 01 3/25/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001746916 3/25/09 AP MIKE GANNON REQUESTED A FOUNDATION INSP 3/25/09 B105 01 4/28/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001760396 4/28/09 DA ok to continue call for reinsp. when doubles are in place B105 02 4/29/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001761832 4/29/09 AP R427 01 7/02/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001789536 7/02/09 DA T/S: 07/01/2009 11:49 AM VBROWN T/S: 07/02/2009 03:20 PM MREARIC 1: tyvek on all outside surfaces 2. plumbing nailguards missing 3. gable ends are not balloon framed. they have a break in the mid-point which must be braced 4. washer box must be 34" above finished floor 5. large windows in master closet and living room when below 18" must be tempered R308.4.6 6. no water in drain pipes for test 7. toilet flanges must be screwed down with galv. or stainless screws 8. support all hips per code 9. support under lam beam at foyer/ living room has been eli minated. provide engineering to prove lamn beam will hold the load R427 02 7/13/09 FS FOUR TRADE ROUGH IN >2500 VRU 001793041 7/13/09 AP mike, the temperd windows have been ordered. i believe we have all others on the infractions list fixed. thanks T/S: 07/13/2009 01:13 PM FSPIVEY I129 01 8/11/09 MR R*INSULATION INSPECTION VRU 001806827 8/11/09 AP T/S: 12/18/2009 11:59 AM MREARIC CONTINUED ONTO NEXT PAGE PREPARED 1/29/10, 13:59:28 INSPECTION TICKET PAGE 3 Harnett'County INSPECTOR: IVR DATE 2/01/10 ADDRESS . 23171 *UNASSIGNED SUBDIV: CONTRACTOR M JIG CONSTRUCTION PHONE (910) 893-5677 OWNER RUBINOSKY MARGARETE PHONE (919) 499-6766 PARCEL 03-9586- - -0028- -03- APPL NUMBER: 09-50021568 CP NEW RESIDENTIAL (SFD) REQUESTED. INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R431 01 12/18/09 MR FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001863026 12/18/09 DP T/S: 12/17/2009 10:40 AM VBROWN CUSTOMER REQUEST AFTERNOON INSP. LATE AS POSSIBLE. T/S: 12/18/2009 12:00 PM MREARIC ~PSinstall protective bar per code R 308.4.exception 5 V over all windows in closet and dining room which have more than 9 sq ft in area and are less than 18" from T floor, on inside and outside Z P front porch requires a 36" guard railing when over 30" w1hback porch guard railing must be 36" min. 4. all steps(over3) require a handrail between 30" and 38" y provide a metal draft-stop collar at roof line around the fireplace flue provide installation info on fireplace provide info on type of sprayed in insulation and the ins installation instructions provide garage door wind rating info. 9. provide floor in front of panel on second floor '3.,remove all 2x4" from shingled roof 'paint crawl space door. IQ, grading around house must shed water away at a rate of 6" in 10' install front steps 14. finish all electric i* parge all blocks together un A/C in crawlspace TRI- install the permanent column in dining room under 2nd floor lam beam R431 02 2/01/10 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001878529 T/S: 01/29/2010 11:50 AM RDCONTE - - COMMENTS AND NOTES - - ♦ ~ { G , ~b I„~`; ~ ale Ha. '~+,a~ t~11~ ~ ~ , i ~ ~ "'^~`!f M y[ COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION & j AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY (ti This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building =,Al Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: n~ Use Classification: 3 Conditional Use Permit No.:: Type of Construction: Building Permit No.: 9 • 5C> en Q/ S ti8 N~1J Owner of Building: Electrical Permit No.: r t h. Building Address: 3 A- -o. r L'n i-a Insulation Permit No.: t r Zoning District: Plumbing Permit No.: Zoning Permit No.: Mech. Permit No.: r , h)) Date: j Z "2 ' In Envir. C.O. No.: Building Official Zoning Official ell ,wr y,~~,~✓: l 1 ~,~r Q~",~' d~" eyb ~~v ,..~~N 01,+ ,.y ~P dp; ,,.y i ~ t l~ lMF f'. 'roH lW ~ ~J l 1lF" { t a tt . ~ J ~v