Loading...
INSPECTIONS PREPARED 4/27/09, 13:59:36 INSPECTION TICKET PAGE 38 Harnett County INSPECTOR: IVR DATE 4/28/09 ADDRESS . : 43 ANNAPOLIS RD SUBDIV: THE GATE @ LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES @ LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57%41 CRAWL, 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - -101 01 4/28/09 DTI R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 - r ------------/-------------'-'-t-'-------------- COMMENTS AND NOTES PREPARED 5/06/09, 13:59:38 INSPECTION TICKET PAGE 23 Harnett County INSPECTOR: IVR DATE 5/07/09 - - - - - - - - - ADDRESS . : 43 ANNAPOLIS RD SUBDIV: THE GATE @ LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES @ LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - B101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP 8104 01 5106109 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5,//007//0099 TI R*BLDG FOUND & TEMP SVC POLE VRU 001764718 COMMENTS AND NOTES - - PREPARED 5/11/09, 13:59:02 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 5/12/09 ADDRESS . : 43 ANNAPOLIS RD SUBDIV: THE GATE @ LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES @ LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD SID. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP 8104 01 5/06/09 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5/07/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001764718 5/07/09 AP B105 01 5/12/09 TI R*OPEN FLOOR VRU 001766271 5-) 29 $p--Ad' - - - COMMENTS AND NOTES - I PREPARED 6/02/09, 13:58:52 INSPECTION TICKET PAGE 31 Harnett County INSPECTOR: IVR DATE 6/03/09 ADDRESS . : 43 ANNAPOLIS RD SUBDIV: THE GATE @ LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES @ LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - -101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP B104 01 5/06/09 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5/07/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001764718 5/07/09 AP B105 01 5/12/09 MR R*OPEN FLOOR VRU 001766271 5/12/09 AP A814 01 6/03/09 TI ADDRESS CONFIRMATION VRU 001776020 R427 01 6/03//~09pr FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001776038 - - COMMENTS AND NOTES PREPARED 6/05/09, 13:59:23 INSPECTION TICKET PAGE 18 Ha_rnltt_County INSPECTOR: IVR DATE 6108109 ADDRESS . : 43 ANNAPOLIS RD SUBDIV: THE GATE @ LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES @ LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP B104 01 5/06/09 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5/07/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001764718 5/07/09 AP B105 01 5/12/09 MR R*OPEN FLOOR VRU 001766271 5/12/09 AP A814 01 6/03/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001776020 6/05/09 AP 43 annapolis rd lot 51 cameron 28326 R427 01 6/03/09 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001776038 6/03/09 DA 1. Need fire caulk for plumbing at stair landing and electrical between master and bathroom. 2. Walls at dining room front must be fire blocked at ceiling level. 3. No water in stand pipe. Okay to side, do not insulate. R427 02 6/08/09 T~I_ FOUR TRADE ROUGH IN >2500 VRU 001778115 05 COMMENTS AND NOTES PREPARED 6/09/09, 13:59:36 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 6/10/09 ADDRESS 43 ANNAPOLIS RD SUBDIV: THE GATE ® LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0501 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES ® LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP B104 01 5/06/09 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5/07/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001764718 5/07/09 AP B105 01 5/12/09 MR R*OPEN FLOOR VRU 001766271 5/12/09 AP A814 01 6/03/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001776020 6/05/09 AP 43 annapolis rd lot 51 cameron 28326 R427 01 6/03/09 DT FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001776038 6/03/09 DA 1. Need fire caulk for plumbing at stair landing and electrical between master and bathroom. 2. Walls at dining room front must be fire blocked at ceiling level. 3. No water in stand pipe. Okay to side, do not insulate. R427 02 6108109 DT FOUR TRADE ROUGH IN >2500 VRU 001778115 6/08/09 AP 1129 01 6/10/09 TI R*INSULATION INSPECTION VRU 001779622 1~ 1101 A,P i G - - - - COMMENTS AND NOTES - PREPARED 8/31/09, 13:59:27 INSPECTION TICKET PAGE 12 Harnett C*inty INSPECTOR: IVR DATE 9/01/09 ADDRESS : 43 ANNAPOLIS RD SUBDIV: THE GATE ® LEXINGTON 159LOTS CONTRACTOR. CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES Q LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP B104 01 5106109 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5/07/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001764718 5/07/09 AP B105 01 5/12/09 MR R*OPEN FLOOR VRU 001766271 5/12/09 AP A814 01 6/03/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001776020 6/05/09 AP V3 annapolis rd lot 51 cameron 28326 R427 01 6103109 DT FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001776038 6/03/09 DA 1. Need fire caulk for plumbing at stair landing and electrical between master and bathroom. 2. Walls at dining room front must be fire blocked at ceiling level. 3. No water in stand pipe. Okay to side, do not insulate. R427 02 6/08/09 DT FOUR TRADE ROUGH IN >2500 VRU 001778115 6/08/09 AP 1129 01 6/10/09 DT R*INSULATION INSPECTION VRU 001779622 6/10/09 AP FOUR TRADE FINAL >2500 VRU 001815281 R431 01 2/01/09 - - - COMMENTS AND NOTES VIOLATION NOTICE 11 1 REMOVE! Harnett County Inspection Department 108 East Front Street • RID. Box 65 Lillington, NC 27546 Phone: (910) 893-7525 Ext. 1 • Fax: (910) 893-2793 Job Name: Cay-i AcsS ~avYA hc\/• Date: !q /I o Address: r` r,<<S; Lot No.: s Permit No.: ( Check Box for Violation ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Footing Foundation Bldg. Elec. Plumb. Mech. Insul. Floor Fram. ❑ ❑ ❑ ❑ ❑ ❑ ❑ Floor Slab MFG. Home Modular Damp/Water Structural Wall Sheath. Other Proof. Violations Found:! 1 Mk-Uowo.,1f r r ce,i Lcle- ow Sj ~J e -2-0 a n ATPc ~ z - 1. J S S c_ S-t a ,.J~ 3 q, Q ;J,ade, AA 6c J C el e- Code Enforcement Official Signature: - Date: It is unlawful for any subcontractor, general contractor, or owner to cover or cause to be covered any part of the work with floor- ing, sheetrock, earth or other material until the proper inspector had ample time to approve the installation WHITE COPY - CONTRACTOR/OWNER YELLOW COPY - INSPECTORS PREPARED 9/01/09, 14:14:27 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 9/02/09 ADDRESS . : 43 ANNAPOLIS RD SUBDIV: THE GATE @ LEXINGTON 159LOTS CONTRACTOR CAVINESS LAND DEVELOPMENT PHONE (919) 481-0503 OWNER PIERCE DEVELOPMENT LLC PHONE PARCEL 09-9565-07- -0282- -51- APPL NUMBER: 09-50021922 CP NEW RESIDENTIAL (SFD) DIRECTIONS : GATES @ LEXINGTON #51 TAKE HWY 24/27 TOWARDS SPRING LAKE. TURN RIGHT ON SAWYERS ROAD AT STARWOOD S/D. KEEP STRAIGHT INTO LEXINGTON PLANTATION. ***POWER CO: WAITING ON CUS*** T/S: 04/16/2009 09:03 AM RDCONTE STRUCTURE: 000 000 57X41 CRAWL 3BED W/GAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/28/09 DT R*BLDG FOOTING / TEMP SVC POLE VRU 001760758 4/28/09 AP B104 01 5/06/09 RD R*BLDG FOUNDATION SURVEY TIME: 17:00 VRU 001764679 5/06/09 AP FOUNDATION SURVEY MEETS THE REQUIREMENTS SET FORTH BY THE PLANNING DEPARTMENT. SINCE THIS IS AN AS BUILT DRAWING, IT DOES NOT SHOW THE DECK. THE DECK WILL NOT BE CONSTRUCTED UNTIL LATER IN THE CONSTRUCTION PROCESS. T/S: 05/06/2009 10:05 AM RDCONTE B103 01 5/07/09 DT R*BLDG FOUND & TEMP SVC POLE VRU 001764718 5/07/09 AP B105 01 5/12/09 MR R*OPEN FLOOR VRU 001766271 5/12/09 AP A814 01 6/03/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001776020 6/05/09 AP 43 annapolis rd lot 51 cameron 28326 R427 01 6/03/09 DT FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001776038 6/03/09 DA 1. Need fire caulk for plumbing at stair landing and electrical between master and bathroom. 2. Walls at dining room front must be fire blocked at ceiling level. 3. No water in stand pipe. Okay to side, do not insulate. R427 02 6/08/09 DT FOUR TRADE ROUGH IN >2500 VRU 001778115 6/08/09 AP 1129 01 6/10/09 DT R*INSULATION INSPECTION VRU 001779622 6/10/09 AP R431 01 9/01/09 DT FOUR TRADE FINAL >2500 VRU 001815281 9/01/09 DA 1. Need handrail for stairs. 2. Need 20 amp receptacle for microwave 3. Master tub receptacle must be fastened T/S: 09/01/2009 02:04 PM DETAYLOR R431 02 2/09 FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001816271 T/S: 09/01/2009 02:14 PM NTART COMMENTS AND NOTES - - JoW, ON )A COUNTY OF HARNTT DEPARTMENT OF BUILDINGE INSPECTION AND PLANNING/DEVELOPMENT , CERTIFICATE OF OCCUPANCY l1~'`Je This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Use Classification: Kfl~c ( Conditional Use Permit No.: Type of Construction: Building Permit Na.: Owner of Building: (ti v w.--r < L Electrical Permit No.: \ S, Building Address: N~ noy c_,l Insulation PermitNo,: x ((ktw'', Zoning District ( e-ron. NC Z~~Z ~r Plumbing Permit No.: u"'r Zoning Permit No.: Mech. Permit No.: lr-A ,1N Date: Z Envir. C.O. No.: t` Buildin,gOfficia~Zoning Official -,dry"'M W°~~ y~J ~1`` ty~Nl (ir to`~~..