Loading...
INSPECTIONS PREPARED 10/19/09, 13:59:04 INSPECTION TICKET PAGE 54 Harnett County INSPECTOR: IVR DATE 10/20/09 ADDRESS . : 91 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.6X57.2 3BDR 2.5BATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10//~ 220/099 T R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 Ayr - COMMENTS AND NOTES PREPARED 10/23/09, 14:03:49 INSPECTION TICKET PAGE 39 Harnett County INSPECTOR: IVR DATE 10/26/09 ADDRESS . : 91 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.8X57.2 3BDR 2.5BATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE.. . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/20/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 10/20/09 AP T/S: October 20, 2009 01:35 PM BSUTTON 1103 01 10/26109 TTI~ R*BLDG FOUND & TEMP SVC POLE VRU 001841154 O 1t f A814 01 10/26/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001841121 10/23/09 AP 91 orchard falls dr lot 625 spring lake 28390 T/S: 10/23/2009 10:26 AM TWARD - - - - COMMENTS AND NOTES - PREPARED 10/29/09, 13:59:02 INSPECTION TICKET PAGE 40 Harnett County INSPECTOR: IVR DATE 10/30/09 ADDRESS . : 91 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.8%57.2 313DR 2.5BATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/20/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 10/20/09 AP T/S: October 20, 2009 01:35 PM BSUTTON 1103 01 10/26/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001841154 10/26/09 AP A814 01 10/26/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001841121 10/23/09 AP 91 orchard falls dr lot 625 spring lake 28390 T/S: 10/23/2009 10:26 AM TWARD B105 01 10/1 0/0 T,~ n R*OPEN FLOOR VRU 001843382 V~- - COMMENTS AND NOTES PREPARED 11/20/09, 14:02:58 INSPECTION TICKET PAGE 42 Harnett'Count~ INSPECTOR: IVR DATE 11/23/09 ADDRESS : 91 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.SX57.2`3BDR 2.5BATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -C C B101 01 10/20/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 10/20/09 AP T/S: October 20, 2009 01:35 PM BSUTTON 1103 01 10/26/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001841154 10/26/09 AP - A814 01 10/26/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001841121 10/23/09 AP 91 orchard falls dr lot 625 spring lake 28390 T/S: 10/23/2009 10:26 AM TWARD 13105 01 10/30/09 KS R*OPEN FLOOR VRU 001843382 10/30/09 AP R427 01 11/23/09 TI FOUR TRADE ROUGH IN >2500 VRU 001853621 - X-3 17 --------------------LL-[---~44---. - COMMENTS AND NOTES Mark Jones, P~ 5tructural ~nglneerinq and nes~gn October 22, 2009 Davidson and Jones Residential 1207 Front Street Raleigh, NC 27619 Ref: Plan Clarification The Luton Residence - Lot 625 Anderson Creek Project No. 09-157 To Whom it may concern; The above referenced plan was reviewed on October 22, 2009 to address the following structural condition(s): 1. Tall wall requirements at Family Room. Based on observations and analysis, the conclusions regarding the condition(s) are: 1. The left side and rear walls of the Family Room (including the wall left of the stairs) shall be framed with 2x6 studs at 16" on center. Thank you for this opportunity to assist you. If you have any questions or need any further assistance, please do not hesitate to call. Respectfully, ` `0%aCt~t►rryI, 032702 Mark E. Jones, PE 102209 ~~i ~''•..FHGINEE~•'5 6425 Glen Dean Court • Raleigh, NC 27603 • ph/fax: (919) 803-2219 • mobile: (919) 395-5618 Mark Jones, ff Structural ~ngmeerincq and be5lgn November 9, 2009 Davidson and Jones Residential 1207 Front Street Raleigh, NC 27619 Ref: Plan Clarification The Luton Residence - Lot 625 Anderson Creek Project No. 09-157 To Whom it may concern; The above referenced plan was reviewed on November 9, 2009 to address the following structural condition(s): 1. Stud column support at garage beam. Based on observations and analysis, the conclusions regarding the condition(s) are: 1. The builder shall add an additional 2 studs to the face of the existing 7 studs supporting the right side of the garage beam. See attached drawing. Thank you for this opportunity to assist you. If you have any questions or need any further assistance, please do not hesitate to call. Respectfully, N,~ARO* ,O~ 4d - 44, 032702 - Mark E. Jones, PE 9 09 l~9'•fIN I NEt 6425 Glen Dean Court • Raleigh, NC 27603 • ph/fax: (919) 803-2219 • mobile: (919) 395-5618 TWO ADDITIONAL STUDS - ATTACH TO EXISTING WITH (2) 12d NAILS AT 12" O.C. VERTICALLY 032702 Sir, II-9-09 ''•.FNGI EQ'•r'Gj 1tt ~J ~i PROJECT 09-123 THE GARFIELD PLAN Mark Jones, I L0CAT10N DAVIDSON AND JONES 6425 GLEN DEAN COURT DESIGNED BY MEJ DATE 1119/09 RALEIGH, NC 27603 2 PHONE: (919) 603-2219 scuE NTS PAGE 2 OF PREPARED 11/24/09, 14:00:31 INSPECTION TICKET PAGE 36 Harnett County INSPECTOR: IVR DATE 11/25/09 - - - - - - ADDRESS . : 91 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.8X57.2 3BDR 2.513ATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/20/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 10/20/09 AP T/S: October 20, 2009 01:35 PM BSUTTON B103 01 10/26/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001841154 10/26/09 AP A814 01 10/26/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001841121 10/23/09 AP 91 orchard falls dr lot 625 spring lake 28390 T/S: 10/23/2009 10:26 AM TWARD B105 01 10/30/09 KS R*OPEN FLOOR VRU 001843382 10/30/09 AP R427 01 11/23/09 MR FOUR TRADE ROUGH IN >2500 VRU 001853621 11/23/09 AP T/S: 11/23/2009 01:30 PM MREARIC I129 01 11/25/09 TI R*INSULATION INSPECTION VRU 001855428 ZS 01 COMMENTS AND NOTES PREPARED 11/25/09, 14:01:14 INSPECTION TICKET PAGE 33 Harnett County INSPECTOR: IVR DATE 11/30/09 ADDRESS 91 ORCHARD FALLS DR SU13DIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.8X57.2 3BDR 2.5BATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - B101 01 10/20/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 10/20/09 AP T/S: October 20, 2009 01:35 PM BSUTTON 1103 01 10/26/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001841154 10/26/09 AP - A814 01 10/26/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001841121 10/23/09 AP 91 orchard falls dr lot 625 spring lake 28390 T/S: 10/23/2009 10:26 AM TWARD B105 01 10/30/09 KS R*OPEN FLOOR VRU 001843382 10/30/09 AP R427 01 11/23/09 MR FOUR TRADE ROUGH IN >2500 VRU 001853621 11/23/09 AP T/S: 11/23/2009 01:30 PM MREARIC 1129 01 11/25/09 R*INSULATION INSPECTION VRU 001855428 11/25/09 DA Current code requires R-38 in ceiling. Need Res Check 4.0 calculated on home to see if it meets code, if not replace R30 insulation with R-38C. Do not sheetrock. T/S: 11/25/2009 08:58 AM KSLATTUM INSULATION INSPECTION TIME: 17:00 VRU 001855626 -7v -A12 I129 02 11/30/09 ~•a S: 1129 TI ~T; 11/25/2009 10:53 AM VBROWN COMMENTS AND NOTES r . ate rt, ~fic F 1f I. I. 1 If ~ I I ' I I I Ali I ; i I I I I I ~ I'r e i 1 1 I l 'il I t I k j' I i I sl I ~ ft f4 ' :III! I I I( ,I  y' i E, II' r ;a i ''!f v ~t t ( I~ I ` I ((l j1 { I~ is ~ i li ~ I j ~i it I ~ ' i it I i i I I~ ~ ~ + i ~ ~ i w ~ ii ifs ' i I~~ I i ~ pr~ 'k ~ ~ fib 1; I' 3 ~ { i j i i ~ ~ ~t j I I: i j 4.2,2 irr~ ~ifIicate e ; CREEK PAID e 625 PNgpg1~~' Garoilna P(Ol 0111' vk%1% 5 naadot. et9Y ~ Rd• Desl9ner IN ULp,TlON 1l INC AS En SY~.ptee ZZ - - SUM NC Loty°n \O~ _.ragg. 3y0 RNER . n+ P plays. A pwnerl e" & JONES GA G Os9 OP-NiIDSOJA lAeumnq i00% zr YWt UA:336 n. coos' ~DEvesON n um UA: SNB b 32 m x ' 25 ` *n ,m 00 6 36.0 0.0 2 trams 3 ' 1000 30.0 0.0 25 ('Amp ,..8 124 300 0 13 564 38.0 00 l8 Ac i.0 00 0380 5 Fla5C0duote S 350 55.0 35. ~dm9 2 FIatCA~ro Ced( 5350 ~ 0.380 / Gg6~n9 Catl~ \ o' 598 % ~i\m93' F\~fi 58 O.C. 0.340 . C~Cm9 W. me ATo.c.Low£ 96 We\\5• W Fra~.Dou 11 0. % Wakx2.,0.28 [thLowx V'f`n2: Vinyl Frame:Dour 6 0400 ,SHGC:0 n Frarne:Dou 0.35 Window 3: Vinyl 35 SHGG: 0.33 `With Low Window C Vinyl Frerne:DodI 58 Sri 10.33 Door 1: Glass I 20 10.0 : SHGC: 0.34 19 0.0 Door 2: Glass 225 SHGC: 029 % Door 3: Solid / tY Door 4: Slid Cams Crawl `I:. Masonry Bloom a build' ht: 3.0' Wall Depth below grade:l sislent dwdt?'~ro/ depot 3.0 Con . Insule5be rade dr~.0' bed--a ~ has bean e ESchr Inside low-g ~ n d ~ budd s e(A , listed iton~.Stre p calcu ationnss submirled Statement: y ~ ~np 1' *4' REScheck Verson 4.2. 2 S'r9 to , Titled f A. Project Title: 625 ANDERSON CREEK Data filename: Unttl0d.rok EScheck Software Version 4.2.2 Inspection Checklist Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Thus, R-36.0 cavity insulation Comments: ❑ Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Q Ceiling 3: Cathedral Ceiling (no attic), R-30.0 cavity insulation Comments: - Q Ceiling 4: Flat Ceiling or Scissor Truss, R-36.0 cavity insulation Comments: Above-Grade Waifs: Q Wall 1: Wood Frame, 16' o.c., R-19.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 16" o.c., R-15.0 cavity insulation Comments: Windows: Q Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.360 For windows without labeled U-factors, describe features: #Panes - Frame Type Thermal Break? - Yes - No Comments: ❑ Window 2: Vinyl Frame:Double Pane with Low-E. U-factor. 0.360 For windows without labeled U-factors, describe features: #Panes - Frame Type Thermal Break? - Yes _ No Comments: ❑ Window 3: Vinyl Frame:Double.Pane with Low-E. U-factor. 0.340 For windows without labeled U-factors, describe features: #Panes - Frame Type Thermal Break? - Yes _ No Comments: ❑ Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.340 For windows without labeled U-factors, describe features: #Panes - Frame Type Thermal Break? - Yes _ No Comments: Note: Up to 15 sq.ft. of glazed fenestration per dwelling is exempt from U-factor and SHGC requirements. Doors: ❑ Door 1: Glass, U-factor: 0.400 Comments: ❑ Door 2: Glass, U-factor: 0.350 Comments: Q Door 3: Solid, U-factor: 0.190 Commends: ❑ Door 4: Solid, 1.1-factor: 0.190 Comments: Project Tide: 625 ANDERSON CREEK Report date: 11125t09 Data filename: Untided.rck Page 2 of 3 l Crawl Space Walls: D Crawl 1: Masonry Block with Empty Cells, 3.0' ht / 1.0' bg / 3.0' ext. insul / 0.0' inside bg depth, R-10.0 continuous insulafion Comments: Exposed earth in unvented crawl space foundations is covered with a continuous vapor retarder. All joints of the vapor retarder are overlapped by 6 inches and are sealed or taped with edges extending at least 6 inches up the stem wall and securely attached. Air Leakage: 17 Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. Lj Recessed lights are either 1) Type IC rated with enclosures sealed/gasketed against leaks to the ceiling, or 2) Type IC rated and ASTM E283 labeled, or 3) installed. inside an air-tight assembly with a 0.5' clearance from combustible materials and a 3' clearance from insulation. Sunrooms: ❑ Sunrooms that are thermally isolated from the building envelope have a maximum fenestration U-factor of 0.50 and the maximum skylight U-factor of 0.75. New windows and doors separating the sunroom from conditioned space meet the building thermal envelope requirements. Materials Identification and Installation: Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and coding equipment and service water heating equipment have been. provided. Insulation R-values and glazing U-tailors are dearly marked on the building plans or specifications. Insulation is installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-vakie without compressing the nsulation. Duet Insulation: ❑ Duds in unconditioned spaces or outside the building are insulated to at least R-8. 0 Duds in floor trusses above unoorMitioned spaces or above the outdoors are insulated to at least R-6. Duct Construction: Air handlers, fitter boxes, and dud connections to flanges of air distribution system equipment or shed metal fittings are sealed and mechanically fastened. E] All joints, seems, and connections are made substantially airtight with tapes, gasketing, mastics (adhesives) or other approved closure systems. Tapes and mastics are rated UL 181A or UL 181 B. D Building framing cavities are not used as supply ducts. Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Additional requirements for tape sealing and moat dud crimping are included by an inspection for compliance with the International Mechanical Code. Temperature Controls: Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is pry. Certificate: A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values; window U-factors; type and efficiency of space-oorditioning and water heating equipment. NOTES TO FIELD: (Building Department Use Only) Project Title: 625 ANDERSON CREEK Report date: 11125109 Data filename: Untitied.rck Page 3 of 3 +Y3 N„ N _ $ 4 Ceiling I Roof 38.00 Wall 15.00 Floor I Foundation 10.00 Ductwork (unconditioned spaces): _ Window 0.38 0.28 p Door 0.40 034 MI, ,MAPS M Water Heater. i,,>'F#'»'nti w:4~t Name: Date: Comments: PREPARED 1/14/10, 13:58:51 INSPECTION TICKET PAGE 24 Harnet'La CoLnty INSPECTOR: IVR DATE 1/15/10 ADDRESS . : 91 ORCHARD FALLS DR SUBDIV: ANDERSON CREEK CLUB CONTRACTOR DAVIDSON & JONES RES LLC PHONE (919) 836-2123 OWNER DAVIDSON AND JONES RESID LLC PHONE PARCEL 01-0535-17- -0100- -23- APPL NUMBER: 09-50023028 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 10/13/2009 08:48 AM VBROWN ANDERSON CREEK CLUB #625, ORCHARD FALLS DRIVE. 27W, LEFT ON NURSERY RD, ANDERSON CREEK CONST ENT, TAKE 2ND RIGHT, ORCHARD FALLS DRIVE LOT 625 ON LEFT. STRUCTURE: 000 000 53.8X57.2 3BDR 2.SBATH SFD GAR,DECK CRWL FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . COUNTY - PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 10/20/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001838127 10/20/09 AP T/S: October 20, 2009 01:35 PM BSUTTON 1103 01 10/26/09 JH R*BLDG FOUND & TEMP SVC POLE VRU 001841154 10/26/09 AP A814 01 10/26/09 TW DRESS CONFIRMATION TIME: 17:00 VRU 001841121 10/23/09 AP 91 orchard falls dr lot 625 spring lake 28390 T/S: 10/23/2009 10:26 AM TWARD B1o5 01 10/30/09 KS R*OPEN FLOOR VRU 001843382 10/30/09 AP R427 01 11/23/09 MR FOUR TRADE ROUGH IN >2500 VRU 001853621 11/23/09 AP T/S: 11/23/2009 01:30 PM MREARIC I129 01 11/25/09 KS R*INSULATION INSPECTION VRU 001855428 11/25/09 DA Current code requires R-38 in ceiling. Need Res Check 4.0 calculated on home to see if it meets code, if not replace R30 insulation with R-38C. Do not sheetrock. T/S: 11/25/2009 08:58 AM KSLATTUM 1129 02 11/30/09 MR R*INSULATION INSPECTION TIME: 17:00 VRU 001855626 11/30/09 AP T/S: 11/25/2009 10:53 AM VBROWN T/S: 11/30/2009 01:19 PM MREARIC R431 01 1/15/10 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001870416 AP ~ T/S: 01/13/2010 02:34 PM NTART COMMENTS AND NOTES - - - - ,n,as,,,. r~:.~..,.- ._r r -,'iti!.s.~-~;~ryZr TiyYevF;'•:eF~s?~,i+.~T~6Y+.;s . _ . .Rw;r:'rv, z+r~e`+k+~YF4'41 I 1 _ s €;r~,~ ar~a~ ra~~ rr~ a+~!~rrk~ ~ 'a~ „,t'.I µt;td ~ ~ COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT ' CERTIFICATE OF OCCUPANCY . This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Use Classification: ~ e c A r n-k z ( Conditional Use Permit No.: A j11 Type of Construction: Building Permit No.: Owner of Building: 4 Don.y Li._C.. Electrical Permit No. 1 . Building Address Insulation Permit No.. R Zoning District: Snc l «cy ~ a ~ )_.gv~ U Plumbing Permit No.: :'~ttll 1 IL? Zoning Permit No.: Mech. Permit No.: C~ Date: f r Envic C.O. No.: §4 Building cial Zoning Official „~tN