IPAC RHTE#09 - s= Z33z2Q Harnett County Department of Public Health
25708
Improvement Permit
A building permit cannot be issued with only an Improvement Permit
~~rt PROPERTY LOCATION:,. S"Yy G y all
ISSUED TO- l~2c a L ~Gt~1c G.c SUBDIVISION Q P 6a LOT #
NEW REPAI ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance:
Type of Structure: -3 r -rJ
Proposed Wastewater System Type: ZS' z-r i er
Projected Daily flow: .34,10 GPD
Number of bedrooms: Number of Occupants: max
Basement ❑Yes 16o
Pump Required: ❑Yes ❑ No be required based on final location and elevations of facilities
Type of Water Supply: El Community MaPublic ❑ Well Distance from well feet
Permit conditions:
Permit valid for.
L!1 Foe years
❑ No expiration
Authorized State Age (A-,V ate: /Z -/O -01 SEE ATTACHED SITE SKETCH
The issuance of this permit by a ealth Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This
site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of
the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.
Construction Authorization
(Required for Building Permit
The construction and installation requirements of Rules .1950, .1952, 1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance
with the attached system layout.
ISSUED TO: 45~1!fOA, ZAA-Z PROPERTY LOCATION: S~< IS--YY CnJY,P12s
SUBDIVISION _ 1JP lUt" LOT #
Facility Type: SF-JL"3 New ❑ Expansion ❑ Repair
Basement? ❑ Yes Z' No Basement Fixtures? ❑ Yes CrNo
Type of Wastewater System" ZS-01& ~ACXTZ4S1~ (Initial) Wastewater Flow: Slvc GPD
(See note below, if applicable
7~5~'ly f2~- by ~r~L (Repair)
Installation Requirements/Conditions Number of trenc es Z
Septic Tank Size /060 gallons Exact length of each trench 12b feet Trench Spacing: Feet on Center
Pump Tank Size gallons Trenches shall be installed on contour at a Soil Cover: lv inches
Maximum Trench Depth of: inches (Maximum soil cover shall not exceed
(Trench bottoms shall be level to +/-1/4" 36" above the trench bottom)
in all directions)
Pump Requirements: ft. TDH vs. GPM 4 inches below pipe
Aggregate Depth: Z inches above pipe
Conditions: --5 PA I>rTC~~S ~z- inches total
i? 30 " ASE
**If applicable: /understand the system type specifed is diferent from the type specified on the app/ication. / accept the speciTcationr of this permit
Owner/Legal Representative Signature: Date:
,..,,1 I„= V'-' F-, ,rc use uiaugt~. flit construcnon numonzauon snap not oe transferred when there is a change in ownership of the site. This
Lonstrucuon Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH
Authorized State Date: !7 -/U '4 9
Construction Authorization Expiration Date: / Z- ld -l
HTE# QT- S -2332ZJZ Permit # 257DH
Harnett County I)epallIllent of Public Health
Site Sketch
ISSUED TO:
Authorized State
N
G-
l
t ..p yo
t~
J ~ o
F
Sit 10'-/ W o)
PROPERTY LOCATON: -';W157Yz1 G'v1''',Q,.J
SUBDIVISION W I' G y LOT #
I ~,O'
Date:
7
Department of Environment, Health and Natural Resources
Division of Environmental Health
On-Site Wastewater Section
SOII.JSITE EVALUATION
for ON-SITE WASTEWATER SYSTEM
Owner: Applicant: 13 Z Z
Address: Date Evaluated: (Z - Z -c3
Proposed Facility: Nc-~) Design Flow (.1949):3Lao
Location of Site: Property Recorded:
Water Supply: LJ lic ❑ Individual ❑ Well
Evaluation Method: tiger Boring ❑ Pit ❑
Type of Wastewater: Sewage ❑ Industrial Process ❑
Sheet:
Property ID:
Lot
File
Code:
Property Size: f
❑ Spring ❑ Other
cut
Mixed
P
R
O
F
I
1940
OIL MORPHOLOGY
.1941
THER
PROFILE FACTORS
L
E
#
Landscape
Position/
Slope %
Horizon
Depth
(In.)
.1941
Structure/
Texture
.1941
Consistence
Minemlolty
.1942
Soil
wetness!
Color
.1943
Soil
Depth IN.
.1936
Sapro
Class
.1944
Restr
Horiz
Profile
Class
& LTAR
l
L qV~
o -Z v
a~
~L (~XitlajtT
41
6- 16
S&
Kt & Amp
~L
fir,. l K J,- i°
3
L 1-°%
~ 1 ~
5L-
arc ,~r,+P
Description
initial
Repair System
Other Factors (.1946):
S st
Site Classif
ti
1948
Available
S
ace
1943
ica
on
p
.
E
l
d
~
S
stem T
e($)
va
uate
By: /L
v
y
yp
b
Site LIAR
Others Present: