INSPECTIONS PREPARED 6/25/09, 13:58:20 INSPECTION TICKET PAGE 44 Harnett County INSPECTOR: IVR DATE 6/26/09 - - - - - - ADDRESS . : LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER SHOWCASE CONSTRUCITON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3ED/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY - PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED:,.-_„RESULT RESULTS/COMMENTS - - - - - - B10101 6/26/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 - b' 26. 9 - nsite contact Pete Parizio/ 910-303-4833 COMMENTS AND NOTES - - PREPARED 7/02/09, 14:09:25 INSPECTION TICKET PAGE 27 Harnett Cou.lty INSPECTOR: IVR DATE 7/06/09 r: 1 ADDRESS IAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER :.SHOWCASE CONSTRUCITON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - B101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 TI ADDRESS CONFIRMATION VRU 001789072 Site Contact Pete Parizo 910-303-4833 B103 01 7/06/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7 & Site Contact Pete Parizio 910-303-4833 COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 07-06-09 PERMIT # 09-50022293 ADDRESS: Lakeland port lot 134 VIOLATIONS: 1. Bed course cannot be thicker than'/<" 2. Repair or have engineer advise Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED .`7/07/09, 14:26:34 INSPECTION TICKET PAGE 36 Harnett Co my INSPECTOR: IVR DATE 7/08/09 ----p ADDRESS . : LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR : SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER : SHOWCASE CONSTRUCTTON INC PHONE (910) 864-0247 PARCEL : 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - - -101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/4" B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD B103 02 7/08/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001791227 '7- 8- 9 Ap- Y~ Site contact Pete Parizio 303-4833 -----------------------------------J--- COMMENTS AND NOTES W~,ci~v~~ Le-7 C-6, Jul. 8. 2009 8:24AM No. 1;66 P. 1/1 TYNDAI'L ENGINEENING 8 DESIGN, P.A. T 919 773-1200 . 1919773.9656 69 shipw..h 069o . Gunar . North Carolina .275]9 w wwAynd all en gin a er(n gzo n, July 7, 2009 Showcase Construction 5506 Yadkin Rd. Fayetteville, NC 28303 Fax: (910) 868-1586 Reference: Engineering Services Lot 134, Carolina Lakes 231 Lake Land Port Harnett County, NC Project No.: 09GAR-F0338 A representative of Tyndall Engineering & Design was on site July 7, 2009 to observe the following item: 1) Existing bed joint thicknesses exceeds 3/4" at various locations along the exterior masonry foundation wall, The following conclusions and recommendations were noted: 1) Based on our observations and worst case analysis, the existing bed joints are adequate as constructed to support the anticipated loading conditions, fm = P/A = 936/72 =13 psi /ft of wall << 120 psi (OK] We appreciate being able to assist you during this phase of the project. If you need further assistance or require additional information please do not hesitate to contact us. Sincerely, Tyndall Engineering & Design p ~ -04 Scan M. Holmes SMIU09GAR-F0338 Prentic , 4~~N11 jNInEMA~ I 10 Page I of 1 PREPARED 7/09/09, 14:00:38 INSPECTION TICKET PAGE 37 Harnett County INSPECTOR: IVR DATE 7/10/09 - - - - - - - ADDRESS . : LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER SHOWCASE CONSTRUCTTON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/41- B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD B103 02 7/08/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001791227 7/08/09 AP Site contact Pete Parizio 303-4833 T/S: 07/08/2009 01:52 PM MREARIC received letter BIOS 01 7/10/09 R*OPEN FLOOR VRU 001792720 / YpOn site contact Pete 910-303-4833 COMMENTS AND NOTES PREPARED 7/16/09, 13:58:04 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 7/17/09 ADDRESS . : LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE : (910) 864-0247 OWNER SHOWCASE CONSTRUCTTON INC PHONE : (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -101 01 6/26/09 MR R-BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/4" B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD B103 02 7/08/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001791227 7/08/09 AP Site contact Pete Parizio 303-4833 T/S: 07/08/2009 01:52 PM MREARIC received letter 3105 01 7/10/09 FS R*OPEN FLOOR VRU 001792720 7/10/09 AP On site Contact Pete 910-303-4833 T/S: 07/10/2009 03:20 PM FSPIVEY R427 01 7J17/09 FOUR TRADE ROUGH IN >2500 VRU 001795533 C7-05 On site contact Pete 910-303-4833 - - COMMENTS AND NOTES - - I PREPARED 8/05/09, 14:19:31 INSPECTION TICKET PAGE 1 Harnett Cqe- tyc; INSPECTOR: IVR DATE 8/06/09 ADDRESS . : 231 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER SHOWCASE CONSTRUCITON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - B101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/4" B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 - SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD B103 02 7/08/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001791227 7/08/09 AP Site contact Pete Parizio 303-4833 T/S: 07/08/2009 01:52 PM MREARIC received letter B105 01 7/10/09 FS R*OPEN FLOOR VRU 001792720 7/10/09 AP On site Contact Pete 910-303-4833 T/S: 07/10/2009 03:20 PM FSPIVEY R427 01 7/17/09 AWN FOUR TRADE ROUGH IN >2500 VRU 001795533 7/17/09 DP On site contact Pete 910-303-4833 Called for 4 trade rough in, house is only partially framed, no roof, open walls etc. $50 re fee T/S: 08/04/2009 09:41 AM NTART R427 02 //8]]/06/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001804707 6r 6 9 T/S: 08/04/2009 09:47 AM NTART - COMMENTS AND NOTES - - - HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 08-06-09 PERMIT # 09-50022293 ADDRESS: 231 lakeland port VIOLATIONS: 1. No aluminum flashing on porch 2. '/2" bolts min. required in garage without eng. Letter 3. Garage truss is unsupported on one end (above steps) 4. Fireblock and draftstop above fireplace 5. Truss g-2 is not strapped to specs on one end 6. Floor area below the air handler is not thick enough for R-30 insulation Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 8/07/09, 13:58:40 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR DATE 8/10/09 ADDRES,s, 231 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR-':V'SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER SHOWCASE CONSTRUCITON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46X62 CRAWL 3BD/313A W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - B101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/4" B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD B103 02 7/08/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001791227 7/08/09 AP Site contact Pete Parizio 303-4833 T/S: 07/08/2009 01:52 PM MREARIC received letter B105 01 7/10/09 FS R*OPEN FLOOR VRU 001792720 7/10/09 AP On site Contact Pete 910-303-4633 T/S: 07/10/2009 03:20 PM FSPIVEY R427 01 7/17/09 BS FOUR TRADE ROUGH IN >2500 VRU 001795533 7/17/09 DP On site contact Pete 910-303-4833 Called for 4 trade rough in, house is only partially framed, no roof, open walls etc. $50 re fee T/S: 08/04/2009 09:41 AM NTART R427 02 8/06/09 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001804707 llx~ 8/06/09 DA T/S: 08/04/2009 09:47 AM NTART T/S: 08/06/2009 10:01 AM MREARIC _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ no aluminum flashing on porch in contasct with concrete ~ 1/2" bolt min. in garage or get engineers letter 3. garage truss is sitting on a hole in top plate , no support ~ fireblock and draftstop above fireplace P'truss girder G-2 is not strapped sufficiently on one end r area below air handler is not thick enough for insulation T/S: 08/06/2009 12:12 PM NTART R427 03 8/10/09 TI FOUR TRADE ROUGH IN >2500 VRU 001806116 CONTINUED ONTO NEXT PAGE PREPARED 8/07/09, 13:58:40 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 8/10/09 ADDRESS;. 231 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR ":SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER SHOWCASE CONSTRUCTTON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - R-/O' 9 App - COMMENTS AND NOTES - - - PREPARED 8/19/09, 14:00:38 INSPECTION TICKET PAGE 23 Harnett County INSPECTOR: IVR DATE 8/20/09 ADDRESS . : 2.31 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR,: SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER SHOWCASE CONSTRUCTTON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) - STRUCTURE: 000 000 46X62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - B101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/4" B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD - B103 02 7/08/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001791227 7/08/09 AP Site contact Pete Parizio 303-4833 T/S: 07/08/2009 01:52 PM MREARIC received letter B105 01 7/10/09 FS R*OPEN FLOOR VRU 001792720 7/10/09 AP On site Contact Pete 910-303-4833 T/S: 07/10/2009 03:20 PM FSPIVEY R427 01 7/17/09 BS FOUR TRADE ROUGH IN >2500 VRU 001795533 7/17/09 DP On site contact Pete 910-303-4833 Called for 4 trade rough in, house is only partially framed, no roof, open walls etc. $50 re fee T/S: 08/04/2009 09:41 AM NTART R427 02 8/06/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001804707 8/06/09 DA T/S: 08/04/2009 09:47 AM NTART T/S: 08/06/2009 10:01 AM MREARIC 1. no aluminum flashing on porch in contasct with concrete 2. 1/2" bolt min. in garage or get engineers letter 3. garage truss is sitting on a hole in top plate , no support 4. fireblock and draftstop above fireplace 5. truss girder G-2 is not strapped sufficiently on one end 6. floor area below air handler is not thick enough for insulation T/S: 08/06/2009 12:12 PM NTART - - - R427 03 8/10/09 MR FOUR TRADE ROUGH IN >2500 VRU 001806116 - - CONTINUED ONTO NEXT PAGE - PREPARED 8/19/09, 14:00:38 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 8/20/09 ADDRESS . : 231 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRAC=,.: SHOWCASE CONSTRUCTION CO. PHONE : (910) 864-0247 OWNER SHOWCASE CONSTRUCITON.INC PHONE : (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8/10/09 AP T/S: 08/10/2009 11:36 AM MREARIC I129 01 8/20/09 TI R*INSULATION INSPECTION VRU 001811066 Site Contact - Pete Parizo 303-4833 COMMENTS AND NOTES PREPARED 11/06/09, 13:58:37 INSPECTION TICKET PAGE 10 Harnett C-punty, INSPECTOR: IVR DATE 11/09/09 - - - - - ADDRESS 231 LAKELAND PORT SUBDIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER ~'HOWCASE CONSTRUCTTON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) STRUCTURE: 000 000 46%62 CRAWL 3BD/3BA W/GAR & DECK FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 3000000.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 6/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001786847 6/26/09 AP Onsite contact Pete Parizio/ 910-303-4833 T/S: 06/26/2009 01:50 PM MREARIC A814 01 7/06/09 MR ADDRESS CONFIRMATION VRU 001789072 7/06/09 DA Site Contact Pete Parizo 910-303-4833 T/S: 07/06/2009 01:00 PM MREARIC bed course cannot be more than 3/4" B103 01 7/06/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001789080 7/06/09 DA Site Contact Pete Parizio 910-303-4833 T/S: 07/06/2009 12:59 PM MREARIC bed course cannot be thicker than 3/4" A814 02 7/06/09 TW DRESS CONFIRMATION TIME: 17:00 VRU 001790989 7/06/09 AP 231 LAKELAND PORT LOT 134 0 SANFORD 27332 T/S: 07/06/2009 04:49 PM TWARD B103 02 7/08/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001791227 7/08/09 AP Site contact Pete Parizio 303-4833 T/S: 07/08/2009 01:52 PM MREARIC received letter B105 01 7/10/09 FS R*OPEN FLOOR VRU 001792720 7/10/09 AP On site Contact Pete 910-303-4833 T/S: 07/10/2009 03:20 PM FSPIVEY R427 01 7/17/09 BS FOUR TRADE ROUGH IN >2500 VRU 001795533 7/17/09 DP On site contact Pete 910-303-4833 Called for 4 trade rough in, house is only partially framed, no roof, open walls etc. $50 re fee T/S: 08/04/2009 09:41 AM NTART R427 02 8/06/09 MR FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001804707 8/06/09 DA T/S: 08/04/2009 09:47 AM NTART T/S: 08/06/2009 10:01 AM MREARIC 1. no aluminum flashing on porch in contasct with concrete 2. 1/2" bolt min. in garage or get engineers letter 3. garage truss is sitting on a hole in top plate , no support 4. fireblock and draftstop above fireplace 5. truss girder G-2 is not strapped sufficiently on one end 6. floor area below air handler is not thick enough for insulation T/S: 08/06/2009 12:12 PM NTART R427 03 8/10/09 MR FOUR TRADE ROUGH IN >2500 VRU 001806116 CONTINUED ONTO NEXT PAGE - - - - PREPARED 11/06/09, 13:56:37 INSPECTION TICKET PAGE 11 Harnett C?unty, INSPECTOR: IVR DATE 11/09/09 ADDRESS . : 231 LAKELAND PORT SU13DIV: CAROLINA LAKES CONTRACTOR SHOWCASE CONSTRUCTION CO. PHONE (910) 864-0247 OWNER ' SHOWCASE CONSTRUCITON INC PHONE (910) 864-0247 PARCEL 03-9585-15- -0134- - - APPL NUMBER: 09-50022293 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - 8/10/09 AP T/S: 08/10/2009 11:36 AM MREARIC I129 01 8/20/09 MR R*INSULATION INSPECTION VRU 001811066 8/20/09 AP Site Contact - Pete Parizo 303-4833 T/S: 08/20/2009 12:31 PM MREARIC R431 01 11/p09/09 TqI~ ~ p FOUR TRADE FINAL >2500 VRU 001847532 - COMMENTS AND NOTES ".r`,r.iY~.4GV^^;"+K„'.-. •n~;,• -,~4, >~s~„au,...,..~;,,!- r ;,:.--,.,.:.w^uw.~.rn•....w+•...riv.rva.usu,*..,!^^`.MCA,~;,i.r'P~M~'!?w^+N-eCi`!->,.^,° ..i 4.i v ~rypr' ' xr n.. COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT, CERTIFICATE OF COMPLIANCE e' This certificate issued pursuant to the requirements of Section 307of the North Carolina Administration Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Use Classification: T7 Conditional Use Permit No.:ndl Type of Construction: Building Permit No.: C~q -S'o022 7-9 '3 ~ Owner of Building: S 14 o!A/CG $LR C ntj5t. Electrical Permit No.: Building Address: 231 Lck1CQL-oa ~(1-t Insulation Permit No.: i k BR~t Zoning District: Plumbing Permit No.: Zoning Permit No.: Mech. Permit No.:.P N Date: 1- S 4 Envic C.O. No.: Building Official Zoning Official ~pol 41 i r r