Loading...
INSPECTIONS PREPARED 4/22/09, 14:00:13 INSPECTION TICKET PAGE 29 Harnett County INSPECTOR: IVR DATE 4/23/09 ADDRESS . : 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOMB 2BBDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8101 01 4/23/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 COMMENTS AND NOTES - - - - PREPARED 5/05/09, 8:10:14 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 5/05/09 - - - - - ADDRESS . : 55 WOLF CREEK IN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP 8111 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/0V509 R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 - - - COMMENTS AND NOTES - - PREPARED 5/21/09, 14:10:00 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 5/22/09 ADDRESS . : 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDR00M FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . : SPA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPFA 00 CP * SPA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - -101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. 8103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/02 TI R*PLUMB UNDER SLAB VRU 001771575 COMMENTS AND NOTES - PREPARED 5/27/09, 13:59:37 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 5/28/09 ADDRESS . : 55 WOLF CREEK IN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co-s should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 TI_ R*BLDG SLAB INSP VRU 001773696 - - COMMENTS AND NOTES Gb(17/LGG7 11: 7L bl GO]L71 OL IRUDG HIYU HO~Ul.1NIGD !"NVG Ul - dq.5002i~U1 Cruse And Associates P.A. 414 E. EDGERTON 6T. DUNK, NC 28334 pKpNB NumouR (910) 8924429 FAX NUMBOt (910) 8926162 Fax Transmittal Form To: LYtiI(jdaQ Iy1 eAanl4G,ta From: /P~.Jpx Csf_ Company Nave: f~ ~r,ff Date sent: G / S-o9 Pkow. I/D 99 7 SZ S- Namber ofPa2cs: F=. 0 89 3 RE: (~/uLFG C~E4t 7at,ylNoritS Message -r7oS. ¢ or- zoo& A!e-Be Foe k - ! A40 de-2- 964"CA15 A 34 Ft,Z E WA"-) A3 "v z-¢ a- z 49. ul c Arcs&IG 7jw, 3 N-e w.cu.. x. ArAct#.p nf-Twt <#o,4S 04ce MJv 6"4e- ,ate THE roc UJ4u- A 3a v fcr i jOeoNe_ 19ZOoz i 7 2-d. Al C 8Gl j . 2 , /douo~J 1S~cck, nloi Ftt c 4 -;p 3N,e 3..JC 4if , ac Ge- 5s.JG Lz) 3 tib" Q~~~s ft-4S A- ¢4 Go~lc et ~3[aGk uJ/5st t~ F/ft.. CL45s~Lelg~P 2-3 4~'.A-t-L- MS 7V VA-4 W 17l+ Yoc.4.40 CcDr4 gj TS 1 F pa SSt o5L.E 774.44 {t- ya u Fi~,,e 'You-P- 77dr L . 'Gb/LO/LGGJ 13: pL JLGb]LOl OL 41CUJG FIVV HJDUt,LFIGJ rHVG UG g°Ic3 Z79S 4" CONCRETE BLOCK ~ P eepOaee°ee / (SOLID FILLED) ~QQ4 4" BRICK VENEER P c NJ T e = C t ° rrhr loU{{{ ROOF SHEATHING WALL TO BE CONSTRUCTED TIGHTLY AGAINST TRUSSES ON BOTH SIDES. FIRE RESTISTANCE RATING DESIGN NO. U904. 3 HOUR RATING. #5 BARS ® 46" CTRS. CTR BARS IN CORE 36" MIN BAR LAPS USE LOW LIFT GROUTING PROCEDURE (FI GG cul'_4 WITH C'e CR~P,^E AT WE( V"nC M<+ left Jj4 Lae'.F>7u1 , A.L eT}(KC" G W.-S 'TO ft ft L*P ViCe- P!TWWRv~ L4 L DIrkF741 L 12" BLOCK FIRE WALL FIRE WALL NOTE: TYPE S MORTAR 1. HORIZONTAL PROJECTION: MINIMUM OF 11 9 GA HORIZONTAL JOINT 2. VERTICAL PROJECTION: MINIMUM OF 30" REINFORCING AT 16" VERTICAL CTRS. NOTE: BLOCK MANUF. TO SUPPLY A BLOCK WITH A WEIGHT THAT MEETS THE REQUIREMENTS OF THE RATED DETAIL. y5 DOWELS AT 48" CTRS PLACE IN F007ING 36" VERTICAL PROJECTION a,' ti 4 a a a as 12" a d 48" 3 HOUR FIREWALL DETAIL N TS Cruse And Associates P.A. WOLFE CREEK TOWNHOMES 414 E. Sdat~arton St. Dunn, North Carolina 28334 - BUIES CREEK, NC PR! (010) 892-"20 FAX; (910) 882-5182 JOB NO. 08-19 Vb/10/ZtjutJ 1.7: 3z 71t7d'dZO1bz UKU= AND A=UUTAILb I"HUC GG •BXUV.U904 - Fire Resistance Ratings - ANSI/UL 263 Page I of 2 u~ 5XUV.U9a4 Fire Resistance Ratings - ANSI/UL 263 Page, Bottom Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the Installation and use of UL listed or Classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered In the field. • When field Issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General. Information for Fire_Reslstance Ratings= AN51/1Jl_ 263 Design No. U904 March 17, 2004 Bearing Wall Rating - 3 MR. Nonbearing Wail Rating - 3 MR. Wad Restricted for Canadian Applications - See Guide 0XVV7 3/." 0. tj MIN, 4 i d, a • e, v izontol Section 1. concrete Blacks' - Various designs. Classification C-3 (3 hr), See Concrete blocks category for list of eligible manufacturers. 2. Mortar - Blocks laid in full bed of mortar, nom. 3/8 in. thick, of not less than 2-1/4 and not more than 3-1/2 parts of clean sharp sand to 1 part Portland cement (proportioned by volume) and not more than 50 http://database.ul.com/cgi-bin/XYV/template/LISEXT/I FRAME/showpage.html?name=B... 6/15/2009 GO/10/LGG] 10:04 ]1 GO]LOl nL umu=,L HINO HDnuulHIG0 rHVG GY BXUV.U904 - Fire Resistance Ratings - ANSI/UL 263 Page 2 of 2 ~f percent hydrated lime (by cement volume). Vertical joints staggered. 3. Portland Cement stucco or Gypsum Plaster - Add 1/2 hr to Classification if used. Attached to concrete boleks (Item 1). 4. Loose Masonry Fill - If all core spaces are filled with loose dry expanded slag, expanded clay or shale (Rotary Kiln Process), water repellant vermiculite masonry fill insulation, or silicone treated partite loose fill insulation add 1 hr to Classification. S. Foamed Plastic' - (Optional-Not Shown) - 1-1/2 in. thick max, 4 ft wide sheathing attached to concrete blocks (Item 1). THE DOW CHEMICAL CO - Type Thermax 'Bearing the UL Classification Mark Last Updated on 2004.03-17 Questions? Notice. of Dlsclalmer Page Top Copyright ® 2OQ9 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not In Itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to ce Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contalned in the Online Certification Directory subject to the following conditions; 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from underwriters Laboratories Inc.- must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: -Copyright ® 2009 Underwriters Laboratories Inc.5" An Ir,dt Den;isn; organita t!ca working for t safer world w-1h inlegriiy. prtclslon end knowledge, i http:// database.ul.com/egi-bin/XYV/template/LISEXT/1 FRAME/showpage.htnil?name=B... 6/15/2009 PREW 6/16/09, 14:08:44 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 6/17/09 i - - ADDRESS 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE : (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE : PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNBOME 2BE)ROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SPA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6// 17 09 TI ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6 PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON - COMMENTS AND NOTES - kEV►s1~,1 ~ z 4" CONCRETE BLOCK C O SS/ 4" BRICK VENEER L - VG I sF: ROOF SHEATHING[ )#lilt WALL TO BE CONSTRUCTED TIGHTLY AGAINST FIRE RESTISTANCE RATING DESIGN TRUSSES ON BOTH SIDES. Np. U804. 3 HOUR RATING. #5 BARS A 48" CTRS, CTR BARS IN CORE 36" MIN BAR LAPS USE LOW LIFT GROUTING PROCEDURE i (NOT OVER 5- PER LIFT) FILL ALL CELLS WITH CONCRETE. PEA GRAVEL, SAND. AND PORTLAND CEMENT ACCEPTABLE. r' USE 3000 PSI MIX. • 12" BLOCK FIRE WALL FIRE WALL NOTE: TYPE 5 MORTAR 1. HORIZONTAL PROJECTION; MINIMUM OF 18" 9 GA HORIZONTAL JOINT 2. VERTICAL PROJECTION: MINIMUM OF 30" REINFORCING AT 16" VERTICAL CTRS. NOTE: BLOCK MANUF. TO SUPPLY A BLOCK WITH A WEIGHT THAT MEETS THE REQUIREMENTS OF THE RATED DETAIL. t36* LS AT 48" CTRS FOOTING ICAL PROJECTION t • ` 12" r. 48" 3 HOUR FIREWALL DETAIL N TS Cruse ggeand Associates P.A. WOLFE CREEK TOWNHOMES Penn North C"olln. 288sa Px: (610) eez-44x6 BUTES CREEK, NC rAx: (610) 0e2-5162 JOB NO. 08-19 - - - - - - - - - - - - - - - - - - - - - Cruse And Associates, P.A. 414 E. ED6ERTON ST. DUNK, NC 28834 PHONE NUMBER (910) 692,4429 FAX NUMBRIt (910) 8925162 Fax Transmittal Form To-, TO/1') 541=0~ Front: ~r4n/pt, C'.2llSF Company Name: 5rOVAMB P C_'s /.✓G Date Sent Phone: 9 e & / Z 9010 7 Number o es: 2 Fax p ep97 RE: loo <AW F.F (J4UL P*-T *L pomp= Message //-7b-4 / , g~k►Jv Rj✓tset..I 5~.~h` 4nJ !o-l4-b9, R"4ft ~ucf- f Sr PO$941 WT1kL y l)7Z+- T*C9 '*4F-. UL D£-(*(.. is 1* 540Z, Ce i+tQ rHSb lAr.~ i `,tpulubRrgi 4" CONCRETE BLOCK i (SOLID FILLED) Q IESS~ 4" BRICK VENEER ? ,JA ° 1 8 AHoG I NE~~ •l((((r~~/~//,~ I~rrllr ~ I ROOF SHEATHING WALL TO B ONSTRUCTED TIGHTLY A INST CF IRE RESTISTANCE RATING DESIGN TRUSSES N BOTH SIDES. 0. U904, 3 HOUR RATING. #5 BARS 48" CTRS. CTR BA IN CORE 36" MI BAR LAPS USE W LIFT GROUTING PROCEDURE (F L CELLS WITH CONCRETE AT EACH BAR LOCATION. ALL OTHER CELLS TO BE FILLED PER UL DETAIL.) 12" BLOCK FIRE WALL FIRE WALL NOTE: TYPE S MORTAR 1. HORIZONTAL PROJECTION: MINIMUM OF 18" 9 GA HORIZONTAL JOINT 2. VERTICAL PROJECTION: MINIMUM OF 30" REINFORCING AT 16" VERTICAL CTRS. NOTE: BLOCK MANUF, TO SUPPLY A BLOCK WITH A WEIGHT THAT MEETS THE REQUIREMENTS OF THE RATED DETAIL. 5 DOWELS AT 48" CTRS LACE IN FOOTING 3 VERTICAL PROJECTION v a 4 . e ~ e r e r a 12" v 48" 3 HOUR FIREWALL DETAIL NTS Cruse And Associates P.A. 414 Edgerton WOLFE CREEK TOWNHOMES Duna. . North Ca h Cast.roline E8334 BUIES CREEK, NC P (:t) esz-s 62 JOB NO. 08-19 0 X15002170 BXUV.U904 - Fire Resistance Ratings - ANSVUL 263 Pagel of 2 ONLINE CERIIFICAIJONS DIRECTORY BXUV.U904 Fire Resistance Ratings - ANSI/UL 263 Page, Bottom Design/System/Construction/Assembly Usage Disclaimer • Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation ano use of UL Listed or classified products, equipment, system, devices, and materials. • Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. • When field issues arise, it Is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 S?e. Gene rAl.)0fprrrTlgon c, re Resistance Ratings - &b LS 283 DeWgn No. U904 March 17, 2004 Bearing Wall Rating - 3 NR. Nonbearing Wall Rating - 3 MR. Lewd Restricted for Canadian Applications - See Guide 6XUy7 J ~ 0, 0 7.3/8' MIN. 4 ~r C 4 3 horizontflE Section V 4 ~ 1. Concrete Blocks• - various designs. Classification C-3 (3 hr). See Concrete Blocks category for list of eligible manufacturers. 2. Mortar - Blocks laid in full bed of mortar, nom. 318 in. thick, of not less than 2-1/4 and not more than 3-1/2 parts of clean sharp sand to 1 part Portland cement (proportioned by volume) and not more than 50 f,«.,. „I b.n7-1,:n/XW/tcmnla}P/T 7CRTCT/1 FR ATv1T7/ah^u AoP htMI9"ArnP=R. f,/15/7nm BXi1V.U904 - Fire Resistance Ratings - ANSVUL 263 Page 2 of 2 percent hydrated lime (by cement volume). vertical joints staggered. 3. Portland Cement Stucco or gypsum Plaster - Add 112 hr to Classification If used. Attached to concrete bolcks (item 1). 4. Loose Masonry Fill - If all core spaces are filled with loose dry expanded slag, expanded clay or shale (Rotary Kiln Process), water repellant vermiculite masonry fill insulation, or silicone treated perilte loose fill insulation add 1 hr to Classification. 5. Foamed Plastics - (Optional-Not Shown) - 1-1/2 In. thick max, 4 ft wide sheathing attached to concrete blocks (Item 1). THE DOW CHEMICAL CO - Type Thermax "Bearing the UL Classification Mark Last tjpda.Wd on 2004-03-17 QueaLons? Ngtce of olsclailner P$e T v ^ qqPxr-gh1;_0_;lW.9 UnQe[Df)te~ La.bo~Sprp _?n~® The appearance of a company's name or product in this database does not In itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and In a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement 'Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc.' must appear adjacent to the extracted material. in addition, the reprinted material must Include a copyright notice in the following format: "Copyright ® 2009 underwriters Laboratories Inc. V An !ndeoendeni organizal.on working for a safer world wiih Integrity, precision and knowledge. Cruse And Associates, P.A. 414 E. EDGERTON ST. DUNK NC 28334 PHONE NUMBER (91.0) 892.44$9 FAX NUMBER (910) 892 182 Fax Transmittal Form To: pb ry~ C G~ Fron1 pN C C n my Nume:, J~ ~"C.c t.,n7 r,J9Pfi~T16 note seat G - D - Phone: d 7 5'x 57 Nwnber o P es: F fd 993 27 9.3 RE: W oL1~E C,~ti¢K TpuJn~ s Message 9t SctA45CO, THAY 44 Y" ycure 4-s,5tsraWcz. ~0 VVI LVIL VJ VJ. .aL J>.V VJLJL VL VI\VJL "n.v 1'ly1JV V11"IV.J i VL Cruse And ASSK1814 s, P.A. 414 E. EDGERTON ST. DuNN, NC 26934 PHONE NUMBER (910) 692.4429 FAX NUMBER (910) 692-5162 fix rMsmiflar form To: Tom Stafford From: Randy Cruse Company Name: Stafford Land Co., Inc. Date Sent: 6-16-09 Phone: 910 691-9808 919 422-3987 Number o Pages: 4 Fax: 910)-692-9801 RE: Wolfe Creek Fire Wall Me~sa~e I am attaching a revised detail as requested along with a UL detail. Please contact me if you have further questions. Cc: Mr. Lynwood McDonald, Harnett County Inspections Department PREPARED 7/15/09, 13:58:04 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 7/16/09 ADDRESS 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS : WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES : LXMN 3/18/08 co-s should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001762556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/0 T~Y THREE TRADE ROUGH IN VRU 001794882 4-9.5 Rough-in inspection for framing, plumbing and electrical. - - - COMMENTS AND NOTES - - - PREPARED 7/22/09, 8:05:00 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 7/22/09 ADDRESS . : 55 WOLF CREEK IN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SPA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - -101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP B111 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. 8103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA B111 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794882 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. Seal joint from sheetrock to roof deck with firecaulk. No mechanical inspection done. ok to side- DO NOT INSULATE R225 01 7/22/D9 TI_„ _ TWO TRADE ROUGH IN VRU 001798032 Reinspection rough-in framing; and rough-in HVAC inspection. - COMMENTS AND NOTES PREPARED 7/23/09, 13:58:14 INSPECTION TICKET PAGE 15 Harnett County INSPECTOR: IVR DATE 7/24/09 ADDRESS . : 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS : WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES : LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNBOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794882 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. Seal joint from sheetrock to roof deck with firecaulk. No mechanical inspection done. ok to side- DO NOT INSULATE R225 01 7/22/09 BS TWO TRADE ROUGH IN VRU 001796032 7/22/09 AP Reinspection rough-in framing; and rough-in HVAC inspection. T/S: July 22, 2009 02:45 PM BSUTTON I129 01 79 R*INSULATION INSPECTION VRU 001799238 4?7 'TZ_-65 Insualtion Inspection COMMENTS AND NOTES - PREPARED 7/23/09, 13:58:14 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 7/24/09 ADDRESS . : 59 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021702 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #11 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SPA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759240 4/23/09 AP B111 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763754 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764182 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771583 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772219 5/26/09 CA 8111 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773704 5/28/09 AP R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794890 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. seal sheetrock joint to roof deck with firecaulk. No mechanical inspection done. ok to side DO NOT INSULATE R225 01 7/22/09 BS TWO TRADE ROUGH IN VRU 001798057 7/22/09 AP Reinspection rough-in.framing; and rough-in HVAC inspection. T/S: July 22, 2009 02:45 PM BSUTTON I129 01 -77/~ 24/0,9 R*INSULATION INSPECTION VRU 001799246 `U/~ 7 T Insualtion Inspection - COMMENTS AND NOTES - - - PREPARED 7/27/09, 13:58:25 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 7/28/09 ADDRESS . : 55 WOLF CREEK LN SUBDIV: CONTRACTOR :-STAFK_ORD CUSTOM HOMES PHONE (910) 692-9806 OWNER iSTAFEbRD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOMB 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - 3101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794882 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. Seal joint from sheetrock to roof deck with firecaulk. No mechanical inspection done. ok to side- DO NOT INSULATE R225 01 7/22/09 BS TWO TRADE ROUGH IN VRU 001798032 7/22/09 AP Reinspection rough-in framing; and rough-in HVAC inspection. T/S: July 22, 2009 02:45 PM BSUTTON 1129 01 7/24/09 BS R*INSULATION INSPECTION VRU 001799238 7/24/09 AP Insualtion Inspection T/S: July 24, 2009 08:48 AM BSUTTON CONTINUED ONTO NEXT PAGE PREPARED 7/27/09, 13:58:25 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 7/28/09 - - - ADDRESS . : 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER :`STAFFbRD LAND COMPANY INC PHONE PARCEL : 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M305 01 7/28/09 T`I^, UQ R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001800507 'V T/S: 07/24/2009 04:26 PM NTART P307 01 7/28/09 TI R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001800515 ~ ~ I-zr A,p T/S: 07/24/2009 04:26 PM NTART COMMENTS AND NOTES PREPARED 9/09/09, 14:03:34 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 9/10/09 ADDRESS . : 55 WOLF CREEK LN SU13DIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER kAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS : WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES : LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj - - STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SFA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - B101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. 8103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794882 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. Seal joint from sheetrock to roof deck with firecaulk. No mechanical inspection done. ok to side- DO NOT INSULATE R225 01 7/22/09 BS TWO TRADE ROUGH IN VRU 001798032 7/22/09 AP Reinspection rough-in framing; and rough-in HVAC inspection. T/S: July 22, 2009 02:45 PM BSUTTON 1129 01 7/24/09 BS R*INSULATION INSPECTION VRU 001799238 7/24/09 AP Insualtion Inspection T/S: July 24, 2009 08:48 AM BSUTTON - CONTINUED ONTO NEXT PAGE - PREPARED 9/09/09, 14:03:34 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 9/10/09 ADDRESS 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M305 01 7/28/09 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001800507 7/28/09 AP T/S: 07/24/2009 04:26 PM NTART P307 01 7/28/09 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001800515 7/28/09 AP T/S: 07/24/2009 04:26 PM NTART R431 01 9/10/09 TI FOUR TRADE FINAL >2500 VRU 001619002 Final. Thank you. COMMENTS AND NOTES PREPARED 9/10/09, 13:59:18 - INSPECTION TICKET - PAGE 11 Harnett County INSPECTOR: IVR DATE 9/11/09 - - - - - ADDRESS 55 WOLF CREEK LN SUBDIV: CONTRACTOP: STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS : WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES : LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BEDROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SEA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SEA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ` - -101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. B103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794882 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. Seal joint from sheetrock to roof deck with firecaulk. No mechanical inspection done. ok to side- DO NOT INSULATE R225 01 7/22/09 BS TWO TRADE ROUGH IN VRU 001798032 7/22/09 AP Reinspection rough-in framing; and rough-in HVAC inspection. T/S: July 22, 2009 02:45 PM BSUTTON 1129 01 7/24/09 BS R*INSULATION INSPECTION VRU 001799238 7/24/09 AP Insualtion Inspection T/S: July 24, 2009 08:48 AM BSUTTON - CONTINUED ONTO NEXT PAGE - - - - PREPARED 9/10/09, 13:59:18 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 9/11/09 ADDRESS 55 WOLF CREEK LN SUBDIV: CONTRACTOTo: STAFFORD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M305 01 7/28/09 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001800507 7/28/09 AP T/S: 07/24/2009 04:26 PM NTART P307 01 7/28/09 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001800515 7/28/09 AP T/S: 07/24/2009 04:26 PM NTART R431 01 9/10/09 TI FOUR TRADE FINAL >2500 VRU 001819002 9/09/09 CA Final. Thank you. T/S: 09/09/2009 02:29 PM NTART CANCELLED FINAL INSPECTION.......... NO ADDRESS CONFIRMATION. R431 02 FOUR TRADE FINAL >2500 VRU 001819945 A814 01 9/11/09 FB ~ /pD,DRESS CONFIRMATION TIME: 17:00 VRU 001819812 9/10/09 AP V T/ S; 09/10/2009 08:46 AM NTART T/S: 09/10/2009 09:16 AM FBURGESS V55 WOLD CREEK LN LILLINGTON, NC 27546 UNIT 10 COMMENTS AND NOTES - - - PREPAREt 9/14/09, 13:58:50 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 9/15/09 ADDRESS . : 55 WOLF CREEK IN SUBDIV: CONTRACTOR STAFFO`ggD CUSTOM HOMES PHONE (910) 692-9808 OWNER 9'PAFFOYtD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) DIRECTIONS : WOLF CREEK TOWNHOMES UNIT #10 TAKE 421 SOUTH TO BUIES CREEK, TURN LEFT ON LESLIE CAMPBELL AVE, THEN TURN LEFT ON KINETT ROAD AND RIGHT ON OLD CHURCH ROAD. **NEED NAME OF POWER CO** T/S: 03/10/2009 03:47 PM RDCONTE LAND NOTES : LXMN 3/18/08 co's should be held until zoning inspection can verify improvements have been installed per Joseph and Samantha tj STRUCTURE: 000 000 TOWNHOME 2BE3)ROOM FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 2.00 PROPOSED USE . . . . . . . SFA SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPFA 00 CP * SEA REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - B101 01 4/23/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001759232 4/23/09 AP Bill 01 5/05/09 TI R*BLDG SLAB INSP VRU 001763747 5/05/09 CA Inspection for backfilling foundation slab before underground plumbing is put in. 8103 01 5/05/09 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001764174 5/05/09 AP P309 01 5/22/09 BS R*PLUMB UNDER SLAB VRU 001771575 5/22/09 AP B104 01 5/26/09 TI R*BLDG FOUNDATION SURVEY VRU 001772193 5/26/09 CA Bill 02 5/28/09 BS R*BLDG SLAB INSP VRU 001773696 5/28/09 AP R125 01 6/17/09 KS ONE TRADE ROUGH IN TIME: 17:00 VRU 001782556 6/17/09 AP PER KEN SLATTUM CUSTOMER NEEDS A FIRE WALL INSPECTION ON THIS STRUCTURE. T/S: 06/16/2009 10:13 AM DJOHNSON Had to add rebar to meet drawing R325 01 7/16/09 BS THREE TRADE ROUGH IN VRU 001794882 7/16/09 DA Rough-in inspection for framing, plumbing and electrical. Seal joint from sheetrock to roof deck with firecaulk. No mechanical inspection done. ok to side- DO NOT INSULATE R225 01 7/22/09 BS TWO TRADE ROUGH IN VRU 001798032 7/22/09 AP Reinspection rough-in framing; and rough-in HVAC inspection. T/S: July 22, 2009 02:45 PM BSUTTON I129 01 7/24/09 BS R*INSULATION INSPECTION VRU 001799238 7/24/09 AP Insualtion Inspection T/S: July 24, 2009 08:48 AM BSUTTON CONTINUED ONTO NEXT PAGE PREPARED 9/14/09, 13:58:50 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 9/15/09 - - - ADDRESS . : 55 WOLF CREEK LN SUBDIV: CONTRACTOR STAFFQRD CUSTOM HOMES PHONE (910) 692-9808 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 11-0670- - -0055- -02- APPL NUMBER: 09-50021701 CP NEW RESIDENTIAL (SFA) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - - - M305 01 7/28/09 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001800507 7/28/09 AP T/S: 07/24/2009 04:26 PM NTART P307 01 7/28/09 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001800515 7/28/09 AP T/S: 07/24/2009 04:26 PM NTART R431 01 9/10/09 TI FOUR TRADE FINAL >2500 VRU 001819002 9/09/09 CA Final. Thank you. T/S: 09/09/2009 02:29 PM NTART CANCELLED FINAL INSPECTION.......... NO ADDRESS CONFIRMATION. R431 02 9/11/09 BS FOUR TRADE FINAL >2500 VRU 001819945 9/11/09 DA Need a ladder at jobsite to access attic space A814 01 9/11/09 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001819812 9/10/09 AP T/S: 09/10/2009 08:46 AM NTART T/S: 09/10/2009 09:16 AM FBURGESS 1v/55 WOLD CREEK IN LILLINGTON, NC 27546 UNIT 10 R429 01 9/15/09 TI n FOUR TRADE FINAL VRU 001821149 Four trade final. - - --------------K COMMENTS AND NOTES - - - - "Mi yy$ 1 cif :fir ~a ( r'.T IIIO COUNTY OF HARNETT I Is DEPARTMENT OF BUILDING INSPECTION Q 3 ~~Z 35 Z, AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY' This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Mgt Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building s construction or use. For-the following: Q_ll a Use Classification: Conditional Use Permit No.: Type of Construction: Building Permit i Owner of Building: Electrical Permit No.: Building Address: Insulation Permit No.: Zoning District: Plumbing Permit No.: Ise' Zoning Permit No.: _ Mech. Permit No.E t, vvi, Da -1 S - 6 9I Envic C.O. No.. - -11K 4 f Building Official Zoning Official ? „r~l krr,, . wy~11 j. i'I ,Jill