Loading...
INSPECTIONS " PREPARED 5/22/09, 14:59:20 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 5/26/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD STRUCTURE: 000 000 60X50 4BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 COMMENTS AND NOTES Fr&-Uc. 6~7SG832 PREPARED 5/28/09, 13:59:37 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 5/29/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR : WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER : WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL : 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD STRUCTURE: 000 000 60X50 4BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/28/09 TI ADDRESS CONFIRMATION VRU 001773936 B103 01 5/29/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001773951 Szg.9 Ae P~z-- COMMENTS AND NOTES ~~Q-r,~. C-~3zso83z PREPARED 6/02/09, 13:58:52 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 6/03/09 ------,T---, ADDRESS 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR : WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER : WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL : 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD STRUCTURE: 000 000 6OX50 4BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/28/09 TI ADDRESS CONFIRMATION VRU 001773936 13103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 TI R*OPEN FLOOR TIME: 17:00 VRU 001776434 <-34 Af=wl A,~p COMMENTS AND NOTES a.. HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 06-03-09 PERMIT# 08-50019796 ADDRESS: 174 omaha VIOLATIONS: 1. Sealed plans call for 4 2xI0's in main girder not three Correct and call for re-inspection. 2. You can continue with framing after you complete #1 Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 6/22/09, 13:59:27 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 6/23/09 - - - - - - ADDRESS 1-f4 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER :'WYNN CONSTRUCTION INC #14 PHONE (919) 526-1347 PARCEL : 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD STRUCTURE: 000 000 60X50 4BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6/03/09 AP 174 omaha dr lot 14 Broadway 27505 B103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x101s on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 TI FOUR TRADE ROUGH IN VRU 001784958 C, EA COMMENTS AND NOTES -~J-I-------- - /Cz /a~~~~ cam. Gam' 7 /C'© u~r' f2 G /1, HAARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 06-23-09 PERMIT # 08-50019796 ADDRESS: 174 omaha VIOLATIONS: 1. Trusses are not strapped for uplift loads...straps are only good for about 400#. Check all trusses against drawings 2. Strap lam beams for uplift at ends Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 6/23/09, 13:58:32 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 6/24/09 R _ ADDRESS 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD STRUCTURE: 000 000 6OX50 413R CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : NEW PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/26/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6/03/09 AP 174 omaha dr lot 14 broadway 27505 B103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 MR R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x10's on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 FOUR TRADE ROUGH IN VRU 001784958 6/23/09 - DA trusses not strapped to specs R425 02 6/24/09 FOUR TRADE ROUGH IN VRU 001785575 -7- COMMENTS AND NOTES HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Inington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 06-24-09 PERMIT # 08-50019796 ADDRESS: 174 omaha VIOLATIONS: 1. Trusses are still not strapped for uplift loads...straps are only good for about 400#. Check all trusses against drawings 2. Provide specs. on strap ratings 3. Fee 50.00 Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 7/08/09, 14:03:32 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 7/09/09 ADDRESS 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD T/S: 07/06/2009 09:21 AM VBROWN PERMITS ON HD REV TO TANK SYSTEM NUMBER OF BDR FROM 4 TO 3. T/S: 07/06/2009 09:21 AM VBROWN STRUCTURE: 000 000 60X50 3BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . FLOOD ZONE X # BEDROOMS . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? NEW WATER SUPPLY . . . . . . . UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6103109 AP 174 omaha dr lot 14 broadway 27505 B103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 MR R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x10's on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 MR FOUR TRADE ROUGH IN VRU 001784958 6/23/09 DA trusses not strapped to specs - R425 02 6/24/09 FOUR TRADE ROUGH IN VRU 001785575 6/24/09 DP trusses still not strapped to specs provide strap rating info fee 50 T/S: 06/25/2009 02:50 PM NTART R425 03 7/09/09 TI FOUR TRADE ROUGH IN TIME: 17:00 VRU 001791904 _:Z- 9 -9 T/S: 07/08/2009 01:01 PM VBROWN - - COMMENTS AND NOTES - - c HARNETT COUNTY Building Inspections Dept. 108 E. Front St. Lillington, NC 27546 910-893-7525 DO NOT REMOVE DATE: 07-09-09 PERMIT # 08-50019796 ADDRESS: 174 omaha VIOLATIONS: 1. Please read the truss documents. Many of the trusses have uplift requirements far in excess of the Simpson H2.5A straps installed Harnett County Building Department Mike Rearic cell# (910) 984- 4772 PREPARED 7/16/09, 13:58:04 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 7/17/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD T/S: 07/06/2009 09:21 AM VBROWN PERMITS ON HD REV TO TANK SYSTEM NUMBER OF BDR FROM 4 TO 3. T/S: 07/06/2009 09:21 AM VBROWN STRUCTURE: 000 000 60X50 3BR CRAWL W/GARAGE k DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP AB14 01 5/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6/03/09 AP 174 omaha dr lot 14 broadway 27505 B103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 MR R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x10's on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 MR FOUR TRADE ROUGH IN VRU 001784958 6/23/09 DA trusses not strapped to specs R425 02 6/24/09 MR FOUR TRADE ROUGH IN VRU 001785575 6/24/09 DP trusses still not strapped to specs provide strap rating info fee 50 T/S: 06/25/2009 02:50 PM NTART R425 03 7/09/09 FOUR TRADE ROUGH IN TIME: 17:00 VRU 001791904 7/09/09 DP T/S: 07/08/2009 01:01 PM VBROWN T/S: 07/09/2009 12:57 PM MREARIC trusses are not strapped to specs. some at girder over garage are not strapped for down loads either R425 04 7/17/09 T~, FOUR TRADE ROUGH IN TIME: 17:00 VRU 001796044 Z?- y1 T/S: 07/16/2009 12:57 PM VBROWN - COMMENTS AND NOTES - - PREPARED 7/20/09, 13:59:34 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 7/21/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD T/S: 07/06/2009 09:21 AM VBROWN PERMITS ON HD REV TO TANK SYSTEM NUMBER OF BDR FROM 4 TO 3. T/S: 07/06/2009 09:21 AM VBROWN STRUCTURE: 000 000 6OX50 3BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 _ 5/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6/03/09 AP 174 omaha dr lot 14 broadway 27505 8103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 MR R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x10's on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 MR FOUR TRADE ROUGH IN VRU 001784958 6/23/09 DA trusses not strapped to specs R425 02 6/24/09 MR FOUR TRADE ROUGH IN VRU 001785575 6/24/09 DP trusses still not strapped to specs provide strap rating info fee 50 T/S: 06/25/2009 02:50 PM NTART R425 03 7/09/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001791904 7/09/09 DP T/S: 07/08/2009 01:01 PM VBROWN T/S: 07/09/2009 12:57 PM MREARIC trusses are not strapped to specs. some at girder over garage are not strapped for down loads either R425 04 7/17/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU 001796044 7/17/09 AP T/S: 07/16/2009 12:57 PM VBROWN 1129 01 7/21/09 TI R*INSULATION INSPECTION VRU 001797307 7-21 -y AP_.M,Q COMMENTS AND NOTES PREPARED 9/28/09, 14:12:11 INSPECTION TICKET PAGE 4 , Harnett County INSPECTOR: IVR DATE 9/29/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR WYN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WY-NN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL : 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD T/S: 07/06/2009 09:21 AM VBROWN PERMITS ON HD REV TO TANK SYSTEM NUMBER OF BDR FROM 4 TO 3. T/S: 07/06/2009 09:21 AM VBROWN STRUCTURE: 000 000 6OX50 3BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . UNKNOWN PERMIT: CPSF 00 CP * SPD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6/03/09 AP 174 omaha dr lot 14 broadway 27505 B103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 01 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 MR R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x10's on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 MR FOUR TRADE ROUGH IN VRU 001784958 6/23/09 DA trusses not strapped to specs R425 02 6/24/09 MR FOUR TRADE ROUGH IN VRU 001785575 6/24/09 DP trusses still not strapped to specs provide strap rating info fee 50 T/S: 06/25/2009 02:50 PM NTART R425 03 7/09/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001791904 7/09/09 DP T/S: 07/08/2009 01:01 PM VBROWN T/S: 07/09/2009 12:57 PM MREARIC trusses are not strapped to specs. some at girder over garage are not strapped for down loads either R425 04 7/17/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU 001796044 7/17/09 AP T/S: 07/16/2009 12:57 PM VBROWN 1129 01 7/21/09 MR R*INSULATION INSPECTION VRU 001797307 7/21/09 AP T/S: 07/21/2009 02:23 PM MREARIC R429 01 9/22/09 TI FOUR TRADE FINAL TIME: 17:00 VRU 001825330 9/21/09 CA T/S: 09/21/2009 01:35 PM JBROCK T/S: 09/21/2009 02:58 PM NTART ANCELLED FINAL INSPECTION..... NO OPERATIONS PERMIT. NJT H824 01 9/24/09 OT ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001827799 9/24/09 AP T/S: 09/25/2009 10:55 AM SSTEWART T/S: 09/25/2009 10:55 AM SSTEWART CONTINUED ONTO NEXT PAGE PREPARED 9/28/09, 14:12:11 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 9/29/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACTOR : WYNNp CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER !-WYNIS CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL : 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R429 02 9/29/09 TI FOUR TRADE FINAL TIME: 17:00 VRU 001828623 ~J. (1 -9 T/S: 09/28/2009 01:51 PM NTART - --r COMMENTS AND NOTES PREPARED 9/30/09, 13:59:57 INSPECTION TICKET PAGE 4 Harryett Cdunty INSPECTOR: IVR DATE 10/01/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 86LOTS CONTRACMR :-,kYNN CONSTRUCTION, INC. PHONE (919) 528-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) DIRECTIONS : TINGEN POINT #14-27W PAST WHHS S/D ON LEFT.JD T/S: 07/06/2009 09:21 AM VBROWN PERMITS ON HD REV TO TANK SYSTEM NUMBER OF BDR FROM 4 TO 3. T/S: 07/06/2009 09:21 AM VBROWN STRUCTURE: 000 000 60X50 3BR CRAWL W/GARAGE & DECK (UK) FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : NEW WATER SUPPLY . . . . . . . UNKNOWN PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - B101 01 5/26/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001772317 5/26/09 AP A814 01 5/28/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001773936 6/03/09 AP V174 omaha dr lot 14 broadway 27505 B103 01 5/29/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001773951 5/29/09 AP B105 D1 6/03/09 MR R*OPEN FLOOR TIME: 17:00 VRU 001776434 6/03/09 DA B105 02 6/04/09 MR R*OPEN FLOOR VRU 001776954 6/03/09 DA 1. plans call for 4 2x10's on main girder ok to continue but call for a re-inspection after correction R425 01 6/23/09 MR FOUR TRADE ROUGH IN VRU 001784958 6/23/09 DA trusses not strapped to specs R425 02 6/24/09 MR FOUR TRADE ROUGH IN VRU 001785575 6/24/09 DP trusses still not strapped to specs provide strap rating info fee 50 T/S: 06/25/2009 02:50 PM NTART R425 03 7/09/09 MR FOUR TRADE ROUGH IN TIME: 17:00 VRU 001791904 7/09/09 DP T/S: 07/08/2009 01:01 PM VBROWN T/S: 07/09/2009 12:57 PM MREARIC trusses are not strapped to specs. some at girder over garage are not strapped for down loads either R425 04 7/17/09 KS FOUR TRADE ROUGH IN TIME: 17:00 VRU 001796044 7/17/09 AP T/S: 07/16/2009 12:57 PM VBROWN 1129 01 7/21/09 MR R*INSULATION INSPECTION VRU 001797307 7/21/09 AP T/S: 07/21/2009 02:23 PM MREARIC R429 01 9/22/09 TI FOUR TRADE FINAL TIME: 17:00 VRU 001825330 9/21/09 CA T/S: 09/21/2009 01:35 PM JBROCK T/S: 09/21/2009 02:58 PM NTART CANCELLED FINAL INSPECTION..... NO OPERATIONS PERMIT. NJT H824 01 9/24/09 OT \/ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001827799 9/24/09 AP T/S: 09/25/2009 10:55 AM SSTEWART T/S: 09/25/2009 10:55 AM SSTEWART - - CONTINUED ONTO NEXT PAGE 7~-eu15-e -4- ( ~ 0 (232. PREPARED 9/30/09, 13:59:57 INSPECTION TICKET PAGE 5 Harnett Cbunty INSPECTOR: IVR DATE 10/01/09 ADDRESS . : 174 OMAHA DR SUBDIV: TINGEN POINTE 66LOTS CONTRACTOR :.gYNN CONSTRUCTION, INC. PHONE (919) 526-1347 OWNER WYNN CONSTRUCTION INC #14 PHONE (919) 528-1347 PARCEL 03-9576- - -0088- -14- APPL NUMBER: 08-50019796 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R429 02 9/29/09 FOUR TRADE FINAL TIME: 17:00 VRU 001828623 9/29/09 DP T/S: 09/28/2009 01:51 PM NTART T/S: 09/29/2009 11:59 AM MREARIC crawlspace door does not fill opening R429 03 r1r0,/01/09 TI _ FOUR TRADE FINAL VRU 001830025 -t-r~i nL7.t~1 Je-"f`T71 COMMENTS AND NOTES S r q p ry uIA~~1.:r ` COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT. f CERTIFICATE OF OCCUPANCY if This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance. this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction. or use. For the following: - { Use Classification: Conditional Use Permit No.: Type of Construction: _ Building Permit No.: O S - 4(g O 1 4 7 9 Fj Owner of Building: (AAA Ir". Electrical Permit No.: l l Building Address: 1 Z q O w gala; 1)r, Insulation Permit No.: 11 Zoning District: Plumbing Permit No.: 1 i Zoning Permit No.: ~ Mech. Permit No.: 1~ ,,`nN,~t! Date. 5 J Envir. C.O. No.: 8 o z Building Official Zoning Official