INSPECTIONS
PREPARED 4/23/09, 13:59:12 INSPECTION TICKET PAGE 22
Harnett County INSPECTOR: IVR DATE 4/24/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS : 938 COKESBURY ROAD
TAKE 210 NORTH, TURN RIGHT ON OLD COATS
ROAD. GO APPROX 4 MILES, TURN LEFT ON
COKESBURY ROAD, GO APPROX 1 MILE, HOME
IS ON THE RIGHT.
**PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE
STRUCTURE: 000 000 31X48 SFD 3BDR 2BATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/li 24/.`09 Tz R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
COMMENTS AND NOTES - - -
TYNDALL
ENGINEERINGB DESIGN, P.A.
T 919773-1200 • c 919 773-9558
do Shlpwash Drive • Gai nar • NorIh Carolina • 27529
w w w. pm d a I I e n g i n e e r i n g. c c m
April 21, 2009
Timberline Roofing
938 Cokesbury Rd.
Fuquay-Varina, NC 27526
Timberline-roofing.com
Reference: 768 Oak Grove Church Rd.
Angier, NC
Project No.: 09GAR-F0196
To Whom It May Concern:
A representative of Tyndall Engineering & Design arrived onsite to observe the existing
foundation, specifically the following items listed below were observed:
1) Foundation observation.
The following conclusions and recommendations were presented for the above-
mentioned items:
1) Based on our visual observations the existing footing excavations had unsuitable
material located throughout the footing. The unsuitable soils should be undercut
(approximately two feet in the rear left corner to four feet in the rear right comer)
to underlying soils exhibiting in-situ strengths of at least 2000 psf. The over
excavated footings should be backfilled with clean washed stone to the plan
footing bearing level prior to footing concrete placement. The over excavation
and backfilling protects the bearing conditions by providing overburden pressure
on the bearing soils. This minimizes the degradation of the fine-grained soils from
water as they are confined. In addition, the use of the stone transfers the loading
to the subsoils, thus reducing the footing pressures to them.
We appreciate the opportunity to assist you during this phase of the project. Should you
need further assistance or require additional information please do not hesitate to contact us.
Sincerely,
Tyndall Engineering & Design
Sean M. Holmes Pr yn r.
SMH\09GAR-F0196
5 GIW Q~~.'
Page I of 1 f'~e'db A
~
""m'nntn~~eti`o
PREPARED 5/11/09, 13:59:02 INSPECTION TICKET PAGE 25
Harnett County INSPECTOR: IVR DATE 5/12/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS : 938 COKESBURY ROAD
TAKE 210 NORTH, TURN RIGHT ON OLD COATS
ROAD. GO APPROX 4 MILES, TURN LEFT ON
COKESBURY ROAD, GO APPROX 1 MILE, HOME
IS ON THE RIGHT.
**PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE
STRUCTURE: 000 000 31X48 SFD 3HDR 213ATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - -
B101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 AP
A814 01 5/12/09 TI ADDRESS CONFIRMATION VRU 001766468
B103 01 5/12/09 TI -i R*BLDG FOUND & TEMP SVC POLE VRU 001766476
r ) z. A-E
COMMENTS AND NOTES
PREPARED 7110'/09, 13:59:17 INSPECTION TICKET PAGE 19
Harnett County INSPECTOR: IVR DATE 7/13/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS : 938 COKESBURY ROAD
TAKE 210 NORTH, TURN RIGHT ON OLD COATS
ROAD. GO APPROX 4 MILES, TURN LEFT ON
COKESBURY ROAD, GO APPROX 1 MILE, HOME
IS ON THE RIGHT.
**PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE
STRUCTURE: 000 000 31X48 SFD 3BDR 2HATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY -
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 AP
A814 01 5/12/09 TI ADDRESS CONFIRMATION VRU 001766468
5/22/09 AP 734 OAK GROVE CHURCH RD ANGIER, NC 27501
B103 01 5/12/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001766476
5/12/09 AE 1. foundation shall be inspected again at rough-in. 7
piers not in due to I beams.
P307 01 7/13/09 T~ R*PLUMB WATER CONNECTION VRU 001792885
COMMENTS AND NOTES
PRF,_RF.DV 7/ZO/09, 13:59:34 INSPECTION TICKET PAGE 18
Harnett County INSPECTOR: IVR DATE 7/21/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS : 936 COKESBURY ROAD
TAKE 210 NORTH, TURN RIGHT ON OLD COATS
ROAD. GO APPROX 4 MILES, TURN LEFT ON
COKESBURY ROAD, GO APPROX 1 MILE, HOME
IS ON THE RIGHT.
**PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE
STRUCTURE: 000 000 31X48 SFD 3BDR 2BATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ. COMPLETED RESULT RESULTS/COMMENTS
- - -
-101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 AP
A814 01 5/12/09 TI ADDRESS CONFIRMATION VRU 001766468
5/22/09 AP 734 OAK GROVE CHURCH RD ANGIER, NC 27501
B103 01 5/12/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001766476
5/12/09 AE 1. foundation shall be inspected again at rough-in. 7
piers not in due to I beams.
P307 01 7/13/09 KS R*PLUMB WATER CONNECTION VRU 001792685
7/13/09 CA could not fin
T/S: 07/13/2009 02:11 PM KSLATTUM
T/S: 07/14/2009 02:40 PM NTART
P307 02 7/15/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001794528
7/15/09 CA T/S: 07/14/2009 02:40 PM NTART
Customer wants a plumbing rough in. No plumbing permit for
this structure. All plumbing has been replaced.
R325 01 7/21/09 TI THREE TRADE ROUGH IN TIME: 17:00 VRU 001797018
-/-2.j (_~k T/S: 07/20/2009 09:10 AM RDCONTE
COMMENTS AND NOTES
Violation Notice
Do Not Remove
Harnett County Inspection Department
102 East Front St P.O. Box 65
I.111ington, NC 27546
Phone (910) 893-7525 Fax (910) 893-2793
09-50021773 July 21, 2009
1. Girder unsupported on carport end of the house under living room picture
window.
2. Ductwork shall have 4 inches of clearance to ground.
3. Need romex connectors on all new wiring to panel.
4. Need load calculation on home with added AC and appliances.
Ken Slattum
PREPARED 7/27/09,-13:58:25 INSPECTION TICKET PAGE 16
Harnett County INSPECTOR: IVR DATE 7/28/09
ADDRESS - 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR AlWTTHTIS GARY LEAMAN PHONE : (919) 557-0000
OWNER MATTHEWS GARY PHONE : (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS : 938 COKESBURY ROAD
TAKE 210 NORTH, TURN RIGHT ON OLD COATS
ROAD. GO APPROX 4 MILES, TURN LEFT ON
COKESBURY ROAD, GO APPROX 1 MILE, HOME
IS ON THE RIGHT.
**PREMISE WAITING ON CUS**
T/S: 0311912009 02:54 PM RDCONTE
STRUCTURE: 000 000 31X48 SFD 3BDR 2BATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPMR 00 CP MECHANICAL RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -
R125 01 7/~ X8/09 TI ONE TRADE ROUGH IN VRU 001800432
g ~,p,:(A
-
PERMIT: CPMV 00 CP 'MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
8101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 -.AP
A814 01 5/12/09 TI ADDRESS CONFIRMATION VRU 001766468
5/22/09 AP 734 OAK GROVE CHURCH RD ANGIER, NC 27501
B103 01 5/12/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001766476
5/12/09 AE 1. foundation shall be inspected again at rough-in. 7
piers not in due to I beams.
P307 01 7/13/09 KS R*PLUMB WATER CONNECTION VRU 001792885
7/13/09 CA could not fin
T/S: 07/13/2009 02:11 PM KSLATTUM
T/S: 07/14/2009 02:40 PM NTART
P307 02 7/15/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001794528
7/15/09 CA T/S: 07/14/2009 02:40 PM NTART
Customer wants a plumbing rough in. No plumbing permit for
this structure. All plumbing has been replaced.
R325 01 7/21/09 THREE TRADE ROUGH IN TIME: 17:00 VRU 001797018
7/21/09 DA T/S: 07/20/2009 09:10 AM RDCONTE
1. Girder not supported on end (under front picture
window).
2. Ductwork shall 4 inches clearance.
3. Need romex connectors on all wiring to panel.
4. Need load calculation on home with the added appliances,
T/S: 07/21/2009 02:27 PM KSLATTUM
R125 01 7/28/09 I ONE TRADE ROUGH IN VRU 001800457
7- Z'
=
PERMIT: CPPR 00 CP PLUMBING RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - -
PREPARED 7/27/09, 13:58:25 INSPECTION TICKET PAGE 17
Harnett'County INSPECTOR: IVR DATE 7/28/09
ADDRESS 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR ~4A7THSWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEtWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
R125 01 7/28/09 T _ ONE TRADE ROUGH IN VRU 001800440
el --LT -
- - - COMMENTS AND NOTES -
PI:ZPAKP,,,) 7/30/09, 13:59:00 INSPECTION TICKET PAGE 16
Harnett County INSPECTOR: IVR DATE 7/31/09
ADDRESS 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577=10000
PARCEL 11-0681- - -0030- - -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS : 938 COKESBURY ROAD
TAKE 210 NORTH, TURN RIGHT ON OLD COATS
ROAD. GO APPROX 4 MILES, TURN LEFT ON
COKESBURY ROAD, GO APPROX 1 MILE, HOME
IS ON THE RIGHT.
**PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE
STRUCTURE: 000 000 31X46 SFD 3BDR 2BATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-101 01 4/17/09 TI R -BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 AP
A814 01 5/12/09 TI ADDRESS CONFIRMATION VRU 001766468
5/22/09 AP 734 OAK GROVE CHURCH RD ANGIER, NC 27501
B103 01 5/12/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001766476
5/12/09 AE 1. foundation shall be inspected again at rough-in. 7
piers not in due to I beams.
P307 01 7/13/09 KS R*PLUMB WATER CONNECTION VRU 001792885
7/13/09 CA could not fin
T/S: 07/13/2009 02:11 PM KSLATTUM
T/S; 07/14/2009 02:4D PM NTART
P307 02 7/15/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001794528
7/15/09 CA T/S: 07/14/2009 02:40 PM NTART
Customer wants a plumbing rough in. No plumbing permit for
this structure. All plumbing has been replaced.
R325 01 7/21/09 THREE TRADE ROUGH IN TIME: 17:00 VRU 001797018 -
7/21/09 DA T/S: 07/20/2009 09:10 AM RDCONTE
1. Girder not supported on end (under front picture
window).
2. Ductwork shall 4 inches clearance.
3. Need romex connectors on all wiring to panel.
4. Need load calculation on home with the added appliances,
T/S: 07/21/2009 02:27 PM KSLATTUM
R125 01 7/28/09 ONE TRADE ROUGH IN VRU 001800457
7/28/09 DA
R325 02 7 /3(11/09 THREE TRADE ROUGH IN TIME: 17:00 VRU 001802941
- COMMENTS AND NOTES ----------1 6 I O-(------
eJul 3, 09 02:55p HOME 9199633300 p.1
5,f 600-.l-.------.----
ocY~_._ lj48a o.~ = .51
- S' loo
i-4 - WIN3
_A1c,
Gas. crr4p...r-- e4
X 3 ysaa - _
15,00
qI
odp
40-
11-29-2006 22:43 TIMBERLINE ROOFING 9195770000 PAGES
gREPAIED 10/19/09, 13:59:04 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 10/20/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS **PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE -
T/S: 10/19/2009 08:44 AM NTART
HIGHWAY 210 NORTH. RIGHT ONTO OLD C
OATS ROAD. GO 4 MILES AND TURN LEFT ONT
O OAK GROVE CHURCH ROAD.
T/S: 10/19/2009 08:49 AM NTART
* WILL BE 1 MILE DOWN ON THE RIGHT.
STRUCTURE: 000 000 31X48 SFD 3BDR 2BATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 AP
A814 01 5/12/09 TI ADDRESS CONFIRMATION VRU 001766468
5/22/09 AP 734 OAK GROVE CHURCH RD ANGIER, NC 27501
B103 01 5/12/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001766476
5/12/09 AE 1. foundation shall be inspected again at rough-in. 7
piers not in due to I beams.
P307 01 7/13/09 KS R*PLUMB WATER CONNECTION VRU 001792865
7/13/09 CA could not fin
T/S: 07/13/2009 02:11 PM KSLATTUM
T/S: 07/14/2009 02:40 PM NTART
P307 02 7/15/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001794528
7/15/09 CA T/S: 07/14/2009 02:40 PM NTART
Customer wants a plumbing rough in. No plumbing permit for
this structure. All plumbing has been replaced.
R325 01 7/21/09 KS THREE TRADE ROUGH IN TIME: 17:00 VRU 001797018
7/21/09 DA T/S: 07/20/2009 09:10 AM RDCONTE
1. Girder not supported on end (under front picture
window).
2. Ductwork shall 4 inches clearance.
3. Need romex connectors on all wiring to panel.
4. Need load calculation on home with the added appliances,
T/S: 07/21/2009 02:27 PM KSLATTUM
R125 01 7/26/09 KS ONE TRADE ROUGH IN VRU 001800457
7/28/09 DA
R325 02 7/31/09 KS THREE TRADE ROUGH IN TIME: 17:00 VRU 001802941
7/31/09 AP
R429 01 10/20/09 TI FOUR TRADE FINAL TIME: 17:00 VRU 001837764
i0 - ?_6 T/S: 10/19/2009 08:27 AM NTART
COMMENTS AND NOTES
Violation Notice
Do Not Remove
Harnett County Inspection Department
102 East Front St P.O. Box 65
Lillington, NC 27546
Phone (910) 893-7525 Fax (910) 893-2795
09-50021773 October 20, 2009
1. Home not ready: No 911 address numbers on house.
2. Unpainted, non treated wood exposed on fascia.
3. Hand rails and guard rails not installed.
4. Ductwork from package unit not sealed.
5. Meter base cover missing. House open around top of meter base.
6. Positive drainage no to code around house.
7. Water beater not on solid pad-Pressure relief valve not taken to exterior.
S. No plastic in crawl space
9. Deck not built to code.
Inspection stopped.
$50.00 re-inspection fee
Ken Slattum
Harnett County Code Official
4
PREPARED 11/06/09, 13:58:37 INSPECTION TICKET PAGE 3
Harnett County INSPECTOR: IVR DATE 11/09/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS.GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
DIRECTIONS **PREMISE WAITING ON CUS**
T/S: 03/19/2009 02:54 PM RDCONTE - h
T/S: 10/19/2009 08:44 AM NTART V
HIGHWAY 210 NORTH. RIGHT ONTO OLD C
OATS ROAD. GO 4 MILES AND TURN LEFT ONT CIN
O OAK GROVE CHURCH ROAD. r„
T/S: 10/19/2009 08:49 AM NTART V
* WILL BE 1 MILE DOWN ON THE RIGHT.
STRUCTURE: 000 000 31X48 SFD 3BDR 2BATH
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . MOVED HOUSE
SEPTIC - EXISTING? . . . . : EXISTING WATER SUPPLY . . . . . . COUNTY
PERMIT: CPMV 00 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
8101 01 4/17/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001756436
4/16/09 CA
B101 02 4/24/09 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001759802
4/24/09 AP
A814 01 5/12/09 TI DRESS CONFIRMATION VRU 001766468
5/22/09 AP 734 OAK GROVE CHURCH RD ANGIER, NC 27501
B103 01 5/12/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001766476
S/12/09 AE 1. foundation shall be inspected again at rough-in. 7
piers not in due to I beams.
P307 01 7/13/09 KS R*PLUMB WATER CONNECTION VRU 001792885
7/13/09 CA could not fin
T/S: 07/13/2009 02:11 PM KSLATTUM
T/S: 07/14/2009 02:40 PM NTART
P307 02 7/15/09 BS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001794528
7/15/09 CA T/S: 07/14/2009 02:40 PM NTART
Customer wants a plumbing rough in. No plumbing permit for
this structure. All plumbing has been replaced.
R325 01 7/21/09 KS THREE TRADE ROUGH IN TIME: 17:00 VRU 001797018
7/21/09 DA T/S: 07/20/2009 09:10 AM RDCONTE
1. Girder not supported on end (under front picture
window).
2. Ductwork shall 4 inches clearance.
3. Need romex connectors on all wiring to panel.
4. Need load calculation on home with the added appliances,
T/S: 07/21/2009 02:27 PM KSLATTUM
R125 01 7/28/09 KS ONE TRADE ROUGH IN VRU 001600457
7/28/09 DA
R325 02 7/31/09 KS THREE TRADE ROUGH IN TIME: 17:00 VRU 001802941
7/31/09 AP
R429 01 10/20/09 _ FOUR TRADE FINAL TIME: 17:00 VRU 001837764
10/20/09 DP /T/S: 10/19/2009 08:27 AM NTART
/1. No 911 numbers on house.
.."2. Unpainted trim exposed to weather.
CONTINUED ONTO NEXT PAGE
PAPARED 11/06/09, 13:58:37 INSPECTION TICKET PAGE 4
Harnett County INSPECTOR: IVR DATE 11/09/09
ADDRESS . : 770 OAK GROVE CHURCH RD SUBDIV:
CONTRACTOR MATTHEWS GARY LEAMAN PHONE (919) 557-0000
OWNER MATTHEWS GARY PHONE (919) 577-0000
PARCEL 11-0681- - - 0030-
- -
APPL NUMBER: 09-50021773 CP MOVED HOUSE
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
V3. Handrails and guardrails not complete.
4. Ductwork around package unit not sealed.
5. Meter base cover missing and house open behind it. No
siding.
6. Positive drainage missing around house. 6 inch fall
out10 feet.
7. Water heater not on solid pad.
8. Pressure relief valve not plumbed to exterior of crawl.
9. Deck not built to code.
T/S: 10/20/2009 02:52 PM KSLATTUM
R429 02 11/05/09 VC FOUR TRADE FINAL TIME: 17:00 VRU 001846385
11/05/09 CA T/S: 11/04/2009 10:23 AM RDCONTE
T/S: 11/05/2009 08:04 AM VBROWN
CUSTOMER CALLED IN AND CAN INSP.
R429 03 11/09/09 Tz P FOUR TRADE FINAL TIME: 17:00 VRU 001846864
T/S: 11/05/2009 08:29 AM DJOHNSON
T/S: 11/05/2009 04:19 PM NTART
COMMENTS AND NOTES - -
r.
~t' 'l ~(((y ((kla ~W' q. 'el'la `f {1~, x`- ~,~,n~~11 i. f i` x a a s •ra M,`-~,+
a
COUNTY OF HARNE,TT
DEPARTMENT: OF BUILDING INSPECTION
AND PLANNING/DEVELOPMENT
,CERTIFICATE`~OF OCCUPANCY w
This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Wyk
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in
compliance with the various ordinances of the County of Harnett regulating development and building
construction or us For the fcllowin :>d1
Use Classification: -QO l~ Conditional Use Permit No.:~
ft F Type of Construction: Building Permit No
Owner of Building: Electrical Permit No.: ' Building Address. Ar nsulation Permit No.: . Pv
5
Zoning District: Plumbing Permit No.. Zoning Permit No.: Mech. Permit No.:
to 1 Cl G 5 Envir. C.O. No.:
Building Official Zoning Official