Loading...
INSPECTIONS PREPARED 9/22/09, 14:17:01 INSPECTION TICKET PAGE 41 Harnett County INSPECTOR: IVR DATE 9/23/09 - - - - - - ADDRESS . : 318 HEATHROW DR SUBDIV: HIGHGROVE@ANDERSON CRK PH2 35L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 01-0504- - -0177- -57- APPL NUMBER: 09-50022814 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/11/2009 11:58 AM JBROCK HIGHGROVE AT ANDERSON CREEK #55 HWY 210 S TO RAY RD TO S/D ON LEFT HAND SIDE TURN ONTO HIGHGROVE DR STRUCTURE: 000 000 SIX44 4BDR SLAB W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 23/09 TI_ , R*PLUMB UNDER SLAB TIME: 17:00 VRU 001825827 , e. T/S: 09/22/2009 1} :39 AM NTART 7-po A, (fed CO NTS AND NOTES - I ..PREPARED 9/23/09, 14:12:26 INSPECTION TICKET PAGE 28 Harnett County INSPECTOR: IVR DATE 9/24/09 =-'--'i-------------------- - ADDRESS . : 318 HEATHROW DR SUBDIV: HIGHGROVE@ANDERSON CRK PH2 35L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 01-0504- - -0177- -57- APPL NUMBER: 09-50022814 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/11/2009 11:58 AM JBROCK HIGHGROVE AT ANDERSON CREEK 455 HWY 210 S TO RAY RD TO S/D ON LEFT HAND SIDE TURN ONTO HIGHGROVE DR STRUCTURE: 000 000 51X44 4BDR SLAB W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 9/23/09 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU 001825827 9/23/09 AP T/S: 09/22/2009 11:39 AM NTART t-pole passed---------------------- A814 01 9/24/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001826684 T/S: 09/23/2009 12:30 PM DJOHNSON B111 01 /24/09 TI / R*BLDG SLAB INSP TIME: 17:00 VRU 001826692 _1 y-d'q jje T/S: 09 23 ~QQ9 152;30 PM DJOHNSON MONOLITHIC SLAB:REQUESTED - - COMMENTS AND NOTES - I ATC Associates of North Carolina, PC 2725 E. Millbrook Rd Suite 121 Raleigh, NC 27604 Phone: 919-871-0999 Fax: 919-871-0336 www.ateassociates.com September 17, 2009 Mr. George Aiken Savvy Homes 207 West Millbrook Road, Suite 115 Raleigh, NC 27609 Ph: 919-787-5158 Fax: 919-787-7570 Re: Foundation Evaluation for Lot 55 Highgrove at Anderson Creek in Spring Lake, North Carolina ATC Project Number: 45.34028.0005 Dear Mr. Aiken, ATC visited the above referenced site to observe and evaluate foundation soils for Lot 55 prior to construction. At the time of our visit, building pad construction was complete and the proposed corners of the building pad were marked by the contractor. ATC performed hand auger and DCP testing at the four comers of the proposed building. ATC performed DCP testing at 1-foot intervals down to satisfactory residual soils or a maximum depth of 5 feet below finish pad elevation. Results, at areas and elevations tested, indicated that soils are satisfactory to support a foundation designed for a net allowable bearing capacity of 2,000 pounds per square foot (psf Respectfully, ATC Associates of North Carolina, PC ,ttk CA jo"Oo SEAL ? 034487 ' A~,Hh .w d ~ Herbert L. Hales, II, P.E. Project Engineer C~J( REScheck Software Version 4.2.2 Compliance Certificate Project Title: Grayson Energy Code: 20061ECC Location: Spring Lake, North Carolina Construction Type: Single Family Conditioned Floor Area: 2998 K Glazing Area Percentage: 8% Heating Degree Days: 3169 Climate Zone: 3 Construction Site: Owner/Agent: Designer/Contractor: 318 Heathrow Spring Lake, NC 28390 Permit # 0950022814 Compliance: Passes on UA Compliance: 13.3% Better Than Coda Maximum UA: 683 Your UA: 592 Maximum SHGC: 0.40 Your SHGC: 0.28 Gross. Cavity Cont Glazing UA . D. Perimeter U-Factor Calling 1: Cathedral Ceiling (no attic) 270 38.0 0.8 7 Ceiling 2: Flat Ceiling or Scissor Truss 1293 38.0 0.8 37 Wall 1: Wood Frame, 16" o.c. 1490 13.0 0.8 98 Window 1: Vinyl Frame:Double Pane with Low-E 230 0.350 81 SHGC: 0.28 Door 1: Glass 18 0.350 6 SHGC: 0.28 Door 2: Solid 42 0.500 21 Wall 2: Wood Frame, 16" o.c. 1508 13.0 0.8 124 Floor 1: Slab-On-Grade:Unheated 190 0.0 198 Insulation depth: 0.0' Floor 2: Al-Wood Jolstliruss:Over Unconditioned Space 431 19.0 0.8 20 Heat Pump 1: Air Source 7.7 HSPF, 13 SEER Air Conditioner 1: ElecMc Central AIr 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been deeig to meet the 20081ECC requirements In REScheck Version 4.2.2 and to comply with the mandatory requirements ' ad in the eck inspection Checklist. Name - Title S naat re Date Project Title: Grayson Report date: 09/24/09 Date filename: C:Oocuments and Settings\Bryan\Desktop\Res Check Templates\Res check template Grayson.rck Page 1 of 1 11f PREPARED V/07/09, 13:58:31 INSPECTION TICKET PAGE 30 Harnett C1nty INSPECTOR: IVR DATE 10/08/09 r' t ADDRESS 318 HEATHROW DR SUBDIV: HIGHGROVEQANDERSON CRK PH2 35L CONTRACTOR 19AVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 01-0504- - -0177- -57- APPL NUMBER: 09-50022814 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/11/2009 11:58 AM JBROCK HIGHGROVE AT ANDERSON CREEK #55 HWY 210 S TO RAY RD TO S/D ON LEFT HAND SIDE TURN ONTO HIGHGROVE DR STRUCTURE: 000 000 51X44 4BDR SLAB W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . : COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 9/23/09 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU 001825827 9/23/09 AP T/S: 09/22/2009 11:39 AM NTART _ t-pole passed---------------------- A814 01 9/24/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001826684 10/02/09 AP 318 heathrow dr lot 55 spring lake 28390 T/S: 10/02/2009 10:09 AM TWARD Blll 01 9/24/09 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001826692 9/24/09 AP T/S: 09/23/2009 12:30 PM DJOHNSON MONOLITHIC SLAB REQUESTED R427 01 10/08/ 9 T S FOUR TRADE ROUGH IN >2500 VRU 001832963 - - COMMENTS AND NOTES - - BPOAU01 Harnett County 10/08/09 Edit Narrative 11:17:39 Application number, type 09 50022819 CP NEW RESIDENTIAL (SFD) Property address . . . . . . 318 HEATHROW DR Type information, press Enter. 1. Point load blocking missing above rear bedroom wher_e_ HVAC ox is o- chin ceiYing. Correct or supply engineering that it is not needed More... F3=Exit F5=Copy F6=Insert F7=Delete F8=Time stamp F12=Cancel F21=User defaults PREPARED 10/08/09, 14:08:51 INSPECTION TICKET PAGE 46 Harnett County INSPECTOR: IVR DATE 10/09/09 - - - - - ADDRESS . : 318 HEATHROW DR SUBDIV: HIGHGROVEQANDERSON CRK PH2 35L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 01-0504- - -0177- -57- APPL NUMBER: 09-50022814 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/11/2009 11:58 AM JBROCK HIGHGROVE AT ANDERSON CREEK #55 HWY 210 S TO RAY RD TO S/D ON LEFT HAND SIDE TURN ONTO HIGHGROVE DR STRUCTURE: 000 000 51X44 4BDR SLAB W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - P309 01 9/23/09 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU 001825827 9/23/09 AP T/S: 09/22/2009 11:39 AM NTART t-Pole passed------------------- A814 01 9/24/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001826684 10/02/09 AP 318 heathrow dr lot 55 spring lake 28390 T/S: 10/02/2009 10:09 AM TWARD B111 01 9/24/09 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001826692 9/24/09 AP T/S: 09/23/2009 12:30 PM DJOHNSON MONOLITHIC SLAB REQUESTED R427 01 10/08/09 BS FOUR TRADE ROUGH IN >2500 VRU 001832963 10/08/09 DA 1. POint load blocking missing above rear bedroom where HVAC box is located in ceiling. Correct or supply engineering that it is not needed M305 01 10/09/09 T R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001834407 14)- T/S: 10/08/2009 02:04 PM NTART P307 01 10/09/09 TR*PLUMB WATER CONNECTION TIME: 17:00 VRU 001834415 16- !q T/S: 10/08/2009 02:04 PM NTART - COMMENTS AND NOTES PREPARED 10115109, 14:00:30 INSPECTION TICKET PAGE 29 Harnett County INSPECTOR: IVR DATE 10/16/09 ADDRESS . : 318 HEATHROW DR SUBDIV: HIGHGROVE@ANDERSON CRK PH2 35L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 01-0504- - -0177- -57- APPL NUMBER: 09-50022814 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/11/2009 11:58 AM JBROCK HIGHGROVE AT ANDERSON CREEK #55 HWY 210 S TO RAY RD TO S/D ON LEFT HAND SIDE TURN ONTO HIGHGROVE DR STRUCTURE: 000 000 51X44 4BDR SLAB W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - P309 01 9/23/09 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU 001825827 9/23/09 AP T/S: 09/22/2009 11:39 AM NTART t-pole passed---------------------- A814 01 9/24/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001826684 10/02/09 AP 318 heathrow dr lot 55 spring lake 28390 T/S: 10/02/2009 10:09 AM TWARD B111 01 9/24/09 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001826692 9/24/09 AP T/S: 09/23/2009 12:30 PM DJOHNSON MONOLITHIC SLAB REQUESTED R427 01 10/08/09 FOUR TRADE ROUGH IN >2500 VRU 001832963 10/08/09 DA 1. Point load blocking missing above rear bedroom where HVAC box is located in ceiling. Correct or supply engineering that it is not needed M305 01 10/09/09 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001834407 10/09/09 AP T/S: 10/08/2009 02:04 PM NTART P307 01 10/09/09 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001834415 10/09/09 AP T/S: 10/08/2009 02:04 PM NTART 1129 01 10/15/09 TI R*INSULATION INSPECTION VRU 001837038 10/15/09 CA T/S: 10/15/2009 08:13 AM NTART R427 02 10/15/09 TI FOUR TRADE ROUGH IN >2500 VRU 001837046 10/15/09 CA T/S: 10/15/2009 08:13 AM NTART T 1129 02 1 /16/0 R*INSULATION INSPECTION TIME: 17:00 VRU 001837616 ~B ^ T/S: 10/15/2009 01:29 PM JBROCK R427 03 10/16/09, / FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001837608 T/S: 10/15/2009 01:29 PM JBROCK COMMENTS AND NOTES - PREPAR2D 1'120/09, 14:02:58 INSPECTION TICKET PAGE 29 Harnett County INSPECTOR: IVR DATE 11/23/09 ADDRESS . : 318 HEATHROW DR SUBDIV: HIGHGROVEWANDERSON CRK PH2 35L CONTRACTOR SAVVY HOMES, LLC PHONE (919) 787-5158 OWNER STAFFORD LAND COMPANY INC PHONE PARCEL 01-0504- - -0177- -57- APPL NUMBER: 09-50022814 CP NEW RESIDENTIAL (SFD) DIRECTIONS : T/S: 09/11/2009 11:58 AM JBROCK HIGHGROVE AT ANDERSON CREEK #55 HWY 210 S TO RAY RD TO S/D ON LEFT HAND SIDE TURN ONTO HIGHGROVE DR STRUCTURE: 000 000 51X44 4BDR SLAB W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : SEWER WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P309 01 9/23/09 JH R*PLUMB UNDER SLAB TIME: 17:00 VRU 001825827 9/23/09 AP T/S: 09/22/2009 11:39 AM NTART t-pole t-pole passed--------- A814 01 9/24/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001826684 10/02/09 AP 318 heathrow dr lot 55 spring lake 28390 T/S: 10/02/2009 10:09 AM TWARD 13111 01. 9/24/09 JH R*BLDG SLAB INSP TIME: 17:00 VRU 001826692 9/24/09 AP T/S: 09/23/2009 12:30 PM DJOHNSON MONOLITHIC SLAB REQUESTED R427 01 10/08/09 BS FOUR TRADE ROUGH IN >2500 VRU 001832963 10/08/09 DA 1. POint load blocking missing above rear bedroom where HVAC box is located in ceiling. Correct or supply engineering that it is not needed M305 01 10/09/09 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001834407 10/09/09 AP T/S: 10/08/2009 02:04 PM NTART P307 01 10/09/09 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001834415 10/09/09 AP T/S: 10/08/2009 02:04 PM NTART I129 01 10/15/09 TI R*INSULATION INSPECTION VRU 001837038 10/15/09 CA T/S: 10/15/2009 08:13 AM NTART R427 02 10/15/09 TI FOUR TRADE ROUGH IN >2500 VRU 001837046 10/15/09 CA T/S: 10/15/2009 08:13 AM NTART I129 02 10/16/09 JH R*INSULATION INSPECTION TIME: 17:00 VRU 001837616 10/16/09 AP T/S: 10/15/2009 01:29 PM JBROCK - ----------------1:25 AM JHALL - - R427 03 10/16/09 JH FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001837608 10/16/09 AP T/S: 10/15/2009 01:29 PM JBROCK 1:25 AM JHALL - - R431 01 11/23/09 TI FOUR TRADE FINAL >2500 VRU 001853993 - COMMENTS AND NOTES - - COUNTY OF HARNE=TT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT ; CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in :9y compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Sir"cam('/ ~ aP~ Use Classification: Conditional Use Permit No.., \ l Type of Construction: Building Permit No.: °ybg Owner of Building: a. V V S L~L Electrical Permit No.: Building Address:3 v'Insulation Permit No.: s Zoning District: Plumbing Permit No.: Zoning Permit No.: Mech. Permit No.: G. D x'2- 3" 0 9 Envic C.O. No.: b Building Official Zoning Official ? ~„dl M" ~ ~ ¢f 5..x m.. ~b' + S~° ' Nl`~ - •'~tl ~w ,,.rM ll~ yy„ =NLuf~ i'y s t l~~ 4 ~ f,i y~ ~ ~1~ l4~ ~ Fj'