INSPECTIONS
PREPARP 10%06/09, 13:58:58 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 10/07/09
ADDRESS . : 237 AVERY SPENCE RD SUBDIV:
CONTRACTOR : PHONE
OWNER MURPHY BILLY DUSTIN & CHRISTY PHONE (919) 557-3843
PARCEL 05-0644- - -0201- -16-
APPL NUMBER: 09-50021515 CP NEW STORAGE BLDG RESIDENTIAL
DIRECTIONS NEAR 265 AVERY SPENCE ROAD FUQUAY
VARINA 27526. 401N, LEFT ON CHRISTIAN
LIGHT RD, LEFT ON AVERY SPENCE RD 1/4
ON LEFT NEXT TO 265 AVERY SPENCE RD.
**PREMISE #02154429**
T/S: 01/28/2009 03:53 PM VBROWN
STRUCTURE: 000 000 40X60 POLE BARN
FLOOD ZONE . . . . : FLOOD ZONE X
PROPOSED USE . . . . . . . POLE BARN SEPTIC - EXISTING? . . . . : NONE
WATER SUPPLY . . . . UNKNOWN
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
R131 01 10/07/09 TI„ _ ONE TRADE FINAL VRU 001832419
✓ 1~6i- -PLEASE INSPECT IN THE AFTERNOON.
.
PERMIT: CPBR 00 CP ELECTRICAL RESIDENTIAL
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - -
R131 01 10/07/09 T ONE TRADE FINAL VRU 001832427
6 -fl 7 b'V PLEASE INSPECT IN THE AFTERNOON.
- COMMENTS AND NOTES -
Violation Notice
Do Not Remove
Harnett County Inspection Department
102 East Front St P.O. Box 65
Lillington, NC 27546
Phone (910) 893-7525 Fax (910) 895-2798
09-50021515 October 7 2009
1. brace bottom chord of trusses per plan
2. Need gf'ei on 120 volt circuits around shop
Ken Slattum
Harnett County Code Official
041
PREPARED 11/03/09, 14:00:06 INSPECTION TICKET PAGE 8
Harnett County INSPECTOR: IVR DATE 11/04/09
ADDRESS . : 237 AVERY SPENCE RD SUBDIV:
CONTRACTOR : PHONE
OWNER MURPHY BILLY DUSTIN & CHRISTY PHONE (919) 557-3843
PARCEL 05-0644- - -0201- -16-
APPL NUMBER: 09-50021515 CP NEW STORAGE BLDG RESIDENTIAL
DIRECTIONS : NEAR 265 AVERY SPENCE ROAD FUQUAY
VARINA 27526. 401N, LEFT ON CHRISTIAN
LIGHT RD, LEFT ON AVERY SPENCE RD 1/4
ON LEFT NEXT TO 265 AVERY SPENCE RD.
**PREMISE #02154429**
T/S: 01/28/2009 03:53 PM VBROWN
STRUCTURE: 000 000 40X60 POLE BARN
FLOOD ZONE . . . . : FLOOD ZONE X
PROPOSED USE . . . . . . . POLE BARN SEPTIC - EXISTING? . . . . : NONE
WATER SUPPLY . . . . . . . UNKNOWN
PERMIT: CPBP 00 CP BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
R131 01 10/07/09 ONE TRADE FINAL VRU 001832419
10/07/09 DA PLEASE INSPECT IN THE AFTERNOON.
Trusses missing one row of web bracing and bottom chord not
braced per plan.
T/S: 10/07/2009 02:32 PM KSLATTUM
R131 02 11/00/09 Tj Q ONE TRADE FINAL VRU 001845310
- - - COMMENTS AND NOTES -
,emu. +,a'~'.:H~~~S7'. "1{"'~:.~~;s -773'c.-~'~"H~y~1':,{~'.e_mil'rR"~ie{~Ll.&?";':'*i~'7FrY°...,_. ;~•ci:dr~sK'r.~.-.`"'~-•ai_. 1(r>'i a....bk.rk-;:.,.
:'1 4 l+yo. .Ikm 4 ` M e~ , `1 - 1N~ 11'IWrin ,,mONl~l (F t,.f ,+11
COUNTY OF HARNETT
DEPARTMENT OF BUILDING INSPECTION
AND PLANNING/DEVELOPMENT
91
This certificate issued pursuant to the requirements of Section 307of the North Carolina Administration
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in
compliance with the various ordinances of the County of Harnett regulating development and building
construction or use. For the following:
Use Classification: SiR Conditional Use Permit No.:
Type of Construction: 1 Building Permit No.: S' ~_a ZI S 15
Owner of Building: u v Electrical Permit No.: S U 0 Z I s 1
Building Address: V1 Irl CJ Insulation Permit No.:
N
Zoning District: Plumbing Permit No.: aa~
Zoning Permit No.: Mech. Permit No.:
- - D Envir. C.O. No.:
s Ding Official Zoning Official
a~