INSPECTIONS PR 8/06/09, 13:58:14 INSPECTION TICKET PAGE 33 HSrnet , County INSPECTOR: IVR DATE 8/07/09 ADDRESS . : 3010 BETHEL BAPTIST RD SUBDIV: J R P WEST ESTATE CONTRACTOR : CHOO'S MOBILE HOME TRANSIT PHONE (910) 850-6572 OWNER MONTE KARI-LYNN PHONE PARCEL 01-0534- - -0059- - - APPL NUMBER: 09-50022434 CP MANUFACTURED HOME RA20R/RA20M CRITERIA - - STRUCTURE: 000 000 28X76 4BDR DWMH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4.00 MOBILE HOME YEAR . . . . . 1.00 PROPOSED USE . . . . . . . DWMH SEPTIC - EXISTING? . . . . EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPDW 00 CP MOBILE HOME DOUBLEWIDE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS T501 01 8/07/09 TI tf R*MOBILE HOME FOUND./ M. WALL VRU 001805988 - COMMENTS AND NOTES Violation Notice Do Not Remove Harnett County Inspection Department Jimmy Hall (910)984-4768 Permit #09-50022434 Date: 8/07/09 1) Need engineer letter for set up of over height home more than '/4 of piers are over 36". 2) Cross over duct not hooked up properly & needs to be 4" from ground. 3) Ground wire for frame on home is not hooked up. 4) All insulation under house needs to be put back up and covered. 5) Drain line needs test per code. 6) Drain line needs to be strapped every 4'. PREPARED 8/28/09, 14:03:31 INSPECTION TICKET PAGE 21 Harnett County INSPECTOR: IVR DATE 8/31/09 - - - - - ADDRESS . : 3010 BETZEL BAPTIST RD SUBDIV: J R P WEST ESTATE CONTRACTOR CHOU"S MOBILE HOME TRANSIT PHONE (910) 850-6572 OWNER MONTE KARI-LYNN PHONE PARCEL 01-0534- - -0059- - - APPL NUMBER: 09-50022434 CP MANUFACTURED HOME RA20R/RA20M CRITERIA STRUCTURE: 000 000 28X76 413DR DWMH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4.00 MOBILE HOME YEAR . . . . . 1.00 PROPOSED USE . . . . . . . DWMH SEPTIC - EXISTING? . . . . EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPDW 00 CP MOBILE HOME DOUBLEWIDE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS T501 01 8/07/09 R*MOBILE HOME FOUND./ M. WALL VRU 001805988 /URN 8/07/09 DP )Need engineer letter for setup of over height home more than 1/4 of piers are over 36". 'A Crossover duct not hooked up properly & needs to be-4" from ground. /)Ground wire for frame not hooked up. A)All insulation under house needs to be put back up & covered up. JF)Drain line needs test per code. )Drain line needs to be strapped every 4' T501 02 /31/09 TI 9 R*MOBILE HOME FOUND./ M. WALL VRU 001814847 n #,I-- COMMENTS AND NOTES - - - - - p.c LARRY W. ANDERSON, P.E. PO BOX 1736 LUMBERTON, NC28359 (910) 671-9530 August 13, 2009 Kari-Lynn Monte 218 Cierra Trail Spring Lake NC 28390 Ref: Mobile Home Foundation Certification 3010 Bethel Baptist Road Spring Lake NC 28390 Kari, I hav visited the above referenced project, as requested, and offer the following improvements to b ' g the unit in compliance with an overheight setup: 1. Install galvanized strap x-bracing on the two bays on tl:e right end of the home, 2. Install surface reinforcing on all double piers under the unit (approximately 24 each). These improvements will bring the unit into compliance when ins, alled. Should you have any questions, please do not hesitate to contact me. Sinc ] \\\\1\t141III IlIII/III Y. CARO(j e ssro,~9 ms's SEAL = r 13325 Larry W. Andtirson, M. LWA/rrc .,~9 Y • •~~Q`?~a\° ollluulW IInN+\\`\~ cc: Charles Dent, Choo Choo Homes NC PE 13325 (910) 608-2808 SC PE 11492 PREPARED 9/29/09, 14:03:43 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 9/30/09 - - - - - - ADDRESS . : 3010 BETHEL BAPTIST RD SUBDIV: J R P WEST ESTATE CONTRACTOR CHOO'S MOBILE HOME TRANSIT PHONE (910) 850-6572 OWNER MONTE KARI-LYNN PHONE PARCEL 01-0534- - -0059- - - APPL NUMBER: 09-50022434 CP MANUFACTURED HOME RA20R/RA20M CRITERIA - - STRUCTURE: 000 000 2BX76 4BDR DWMH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4.00 MOBILE HOME YEAR . . . . . 1.00 PROPOSED USE . . . . . . . DWMH SEPTIC - EXISTING? . . . . EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPDW 00 CP MOBILE HOME DOUBLEWIDE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - - - T501 01 8/07/09 JH R*MOBILE HOME FOUND./ M. WALL VRU 001805988 8/07/09 DP 1)Need engineer letter for setup of over height home more than 1/4 of piers are over 36". 2)Crossover duct not hooked up properly & needs to be 4" from ground. 3)Ground wire for frame not hooked up. 4)All insulation under house needs to be put back up & covered up. 5)Drain line needs test per code. 6)Drain line needs to be strapped every 4' T501 02 8/31/09 JH R*MOBILE HOME FOUND./ M. WALL VRU 001814847 8/31/09 AP waiting on copy of engineer letter------ A814 01 9/29/09 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001828789 9/29/09 AP T/S: 09/29/2009 08:13 AM FBURGESS 3010 BETHEL BAPTIST RD SPRING LAKE, NC 28390 T/S: 09/29/2009 08:14 AM FBURGESS 3010 BETHEL BAPTIST RD SPRING LAKE, NC 28390 Z818 01 9/30/g9 TI PZ*ZONING INSPECTION VRU 001828749 - COMMENTS AND NOTES N,C.S,R, 2048 (Bethel Baptist Road) - 61o" RIw - - ea. N 53'53'26" E 220.58' z F L4 d c o L4 a ~ f N 1 o F 00 w 1 ~y m° Rai. lei x N 75 I%Gr I 04 3s" W SWOOHG38k ~asn' loia"ma '1VA08ddV NHId 311S 1 :4 qol: ~ Win'. .x ~Y of /r yx'• U Ga I fem. an' ~ h'~~' BEs~+$ ~ Yap E~~Eh SIM M E ~E's rraY g m A tf. oEgo ~j ry S ida IcL~~d I~ 9 Vr~ .1 ~ r ♦ y t~ k) ZZ x "V b~ rte (~M* tr p i M1 f e ~ ~ ~ g J 9CA' , 1 r , R E r PREPARED 10/15/09, 14:00:30 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 10/16/09 ---l----- - - - - - - ADDRESS . : 3010.BETHEL BAPTIST RD SUBDIV: J R P WEST ESTATE CONTRACTOR CHOO'S MOBILE HOME TRANSIT PHONE : (910) 850-6572 OWNER MONTE KARI-LYNN PHONE : PARCEL 01-0534- - -0059- - - APPL NUMBER: 09-50022434 CP MANUFACTURED HOME RA20R/RA20M CRITERIA STRUCTURE: 000 000 28X76 4BDR DWMH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4.00 MOBILE HOME YEAR . . . . . 1.00 PROPOSED USE . . . . . . . DWMH SEPTIC - EXISTING? . . . . EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPDW 00 CP MOBILE HOME DOUBLEWIDE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETEV RESULT RESULTS/COMMENTS - - T501 01 8/07/09 JH R*MOBILE HOME FOUND./ M. WALL VRU 001805988 8/07/09 DP 1)Need engineer letter for setup of over height home more than 1/4 of piers are over 36". 2)Crossover duct not hooked up properly & needs to be 4" from ground. 3)Ground wire for frame not hooked up. 4)All insulation under house needs to be put back up & covered up. 5)Drain line needs test per code. 6)Drain line needs to be strapped every 4' T501 02 8/31/09 JH R*MOBILE HOME FOUND./ M. WALL VRU 001814847 8/31/09 AP waiting on copy of engineer letter A814 01 9/29/09 FB ADDRESS CONFIRMATION TIME: 17:00 VRU 001828789 9/29/09 AP T/S: 09/29/2009 08:13 AM FBURGESS 3010 BETHEL BAPTIST RD SPRING LAKE, NC 28390 T/S: 09/29/2009 08:14 AM FBURGESS ',46010 BETHEL BAPTIST RD SPRING LAKE, NC 28390 Z818 01 9/30/09 AD PZ*ZONING INSPECTION VRU 001828749 9/30/09 AP T/S: 09/30/2009 01:02 PM ADRIGGER A814 02 10/05/09 TI ADDRESS CONFIRMATION VRU 001828758 10/01/09 CA T/S: 10/01/2009 10:37 AM NTART T503 01 10/05/09 TI R*MOBILE HOME INSPECTION TIME: 17:00 VRU 001830363 10/05/09 CA T/S: 10/02/2009 09:01 AM NTART T/S: 10/05/2009 08:42 AM NTART T507 01 10/08/09 JH R*MANUFACTURED HOME FINAL TIME: 17:00 VRU 001832922 10/06/09 CA T/S: 10/07/2009 12:30 PM NTART per Kari T507 02 10/16/09 R*MANUFACTURED HOME FINAL VRU 001837160 -----------V---------------------------- COMMENTS AND NOTES COUNTY OF HARNETT~ DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant tothe requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Hamett regulating development and building construction or use. For the fol owing: Use Classrfeation: SFD Conditional Use Permit No.: Type of Construction: Manufactured 2x Building Permit No.: 09-50022434 MH OwnerofBuilding: Bari-Lynn Monte Electrical Permit No.: Building Address: 3010 Bethel Baptist RD Insulation Permit NI Zoning District: NA Plumbing Permit No.: Zoning Permit No.: NA Mach. Permit No.: q~ Date: 10-16-09 Err& C.O. No.: Brad Button HA Building Official Zoning Official e 1121