INSPECTIONS
PREPARED 6/10/09, 13:59:06 INSPECTION TICKET PAGE 3
Harnett County INSPECTOR: IVR DATE 6/11/09
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION -
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 6/11/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
-6 Z4,q -AP-Mi?
- COMMENTS AND NOTES
PREPARED 6/15/09, 13:58:18 INSPECTION TICKET PAGE 5
Harnett County INSPECTOR: IVR DATE 6/16/09
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 06-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
-
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - -
-101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
A814 01 6/16/09 TI ADDRESS CONFIRMATION VRU 001782309
B103 01 6/16/09 TI R*BLDG FOUND & TEMP SVC POLE VRU 001782291
I l
R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
B113 01 6/1166/099 6 TI
~,~Q
6
- - - - COMMENTS AND NOTES - - -
PREPARED 6/22/09, 13:59:27 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 6/23/09
ADDRESS . : 105 CAMERON PINES DR SU13DIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
I
-
-101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
B103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6116109 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP 105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 TI R*OPEN FLOOR VRU 001784974
2 _9 AP-MR
COMMENTS AND NOTES - -
PREPARED 6/24/09, 13:58:14 INSPECTION TICKET PAGE 10
Harnett County INSPECTOR: IVR DATE 6/25/09
- - - - -
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
-
B101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001760246
6/11/09 AP
B103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6/16/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP 105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 MR R*OPEN FLOOR VRU 001784974
6/23/09 AP
E207 01 6/25/09 TI ~R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001786011
6-2- 5,9 A (n (k
- - COMMENTS AND NOTES - - -
PREPARED 7/13/09, 13:59:09 INSPECTION TICKET PAGE 8
Harnett County INSPECTOR: IVR DATE 7/14/09
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - - - - - - - -
B101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
B103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6/16/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP 105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 MR R*OPEN FLOOR VRU 001784974
6/23/09 AP
E207 01 6/25/09 MR R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001786011
6/25/09 AP provide a premise #
T/S: 06/25/2009 12:30 PM MREARIC
R427 01 7/14/09 FOUR TRADE ROUGH IN >2500 VRU 001793611
- COMMENTS AND NOTES
P52EPARED 7/16/09, 13:58:04 INSPECTION TICKET PAGE 15
Harnett County INSPECTOR: IVR DATE 7/17/09
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 6OX60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - - - - -
B101 01 6111109 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
B103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6/16/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP 105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 MR R*OPEN FLOOR VRU 001784974
6/23/09 AP
E207 01 6/25/09 MR R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001786011
6/25/09 AP provide a premise #
T/S: 06/25/2009 12:30 PM MREARIC
R427 01 7/14/09 FOUR TRADE ROUGH IN >2500 VRU 001793611
7/14/09 DA 1. Need engineer to evaluate structural. Point loads from
LVLs carrying floor loads above sitting in open floor spans
unsupported. 2. Trusses in garage max spacing is 16" o.c. -
3. dryer duct too long as installed. 4. Add a receptacle in
front bedroom. Spacing is over 12 Ft. 5. No pressure on gas
test. 6.Deck stairs need proper support at bottom.7. LVL
cut sheet calls for 9.5 LVLs, 9.25 installed. OK TO SIDE/
DO NOT INSULATE
R427 02 7/17/09 TI FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001795996
-7- cl T/S: 07/16/2009 12:41 PM VBROWN
COMMENTS AND NOTES
Mark ~ , Jones, p~
5tr1XWrA ENirleerinq and resign
July 16, 2009
Wynn Construction
2550 Capitol Drive, Suite 101
Creedmoor, NC 27522
Ph: (919) 528-,1347
Fax: (919) 529-4145
Ref: Engineering observations and Analysis
Lot 3 Cameron Pines
The Roxbury Plan
Project No. 08-162
To Whom it may concern;
The above referenced site was visited on July 15, 2009 to address the following structural
condition(s):
1. Floor truss system does not match plans.
Based on analysis, the conclusions regarding the condition(s) are:
1. The provided and installed truss system is adequate to support the required design loads.
However, the foundation shall be modified with additional joists to support new point
loads as shown on the attached drawing, Sheet 2 of 2. Additionally, the 2-ply 9'k" LVL
header above the opening between the Breakfast and Family Room is adequate to support
the required design loads.
Thank you for this opportunity to assist you. If you have any questions or need any further
assistance, please do not hesitate to call.
Respectfully, \,0%%111urrp1~"
%
f
Mark E. Jones, PE 7-
% i 03Z1O1 i
7-16-09 i
,yMrt wt' g
6425 Glen Dean Court • Raleigh, NC 27603 • ph/fax: (919) 803-2219 • mobile: (919) 395-5618
SOON 'S:':'"
Z d OUCION OL'I 'su9ls90 M ijd1E:d1
I. Br MPS WALL ON
1 CANTILEVER I8rxrCONTCONC
j I
LOCATE ACCESS
-
-
fj
ABLE
j
c I
I ~I
I ~ I ml
8'-f ° ga 1' I
I
I II ~ I 1
I I
_ _ i ~ ~ (8) 2x10 GIHOER ~
TRIPLE JOIST
16'7116' YPIERSwV I
O 30' x 10'
d
m (TYPI UN T-r
o~ cOW load
TRIPLE JOIST
I 11 I
I r~ f
I I
s~
,t rrrup, s-
I ~
032102 i I ~
-17 It
~~~nnnnNNP
PARTIAL FOUNDATION PLAN
PFDJECr •E
LAN
Mark Jones, P~ L0C'i°" LOT LOT 3 3 CAMERON PINES
PINES
6125 GLEN DEAN COURT °"IE
7118109
RALEIGH, NC 27603
PHONE; (919) 803.2219 VAE NTS PAM 2 6 2
E 'd 5E6E'~N .~I '3u91390 VIA AdhE:?j 6503 '9,,inr
PREPARED 7/20/09, 13:59:34 INSPECTION TICKET PAGE 11
Harnett County INSPECTOR: IVR DATE 7/21/09
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
B101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
8103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6/16/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP 105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 MR R*OPEN FLOOR VRU 001784974
6/23/09 AP
E207 01 6/25/09 MR R*ELEC TEMP SERVICE POLE TIME: 17:00. VRU 001786011
6/25/09 AP provide a premise #
T/S: 06/25/2009 12:30 PM MREARIC
R427 01 7/14/09 BS FOUR TRADE ROUGH IN >2500 VRU 001793611
7/14/09 DA 1. Need engineer to evaluate structural. Point loads from
LVLS carrying floor loads above sitting in open floor spans
unsupported. 2. Trusses in garage max spacing is 16" o.c.
3. dryer duct too long as installed. 4. Add a receptacle in
front bedroom. Spacing is over 12 Ft. 5. No pressure on gas
test. 6.Deck stairs need proper support at bottom.7. LVL
cut sheet calls for 9.5 LVLS, 9.25 installed. OK TO SIDE/
DO NOT INSULATE
R427 02 7/17/09 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001795996
7/17/09 DA T/S: 07/16/2009 12:41 PM VBROWN
floor truss in garage that was moved have truss plates
that have separated. Need to get repair or have
manufacturer repress truss plates.
T/S: 07/17/2009 12:36 PM
KSLATTUM
I129 01 7/21/09 TI R*INSULATION INSPECTION VRU 001797281
R427 03 7/21/09 T OUR TRADE ROUGH IN >2500 VRU 001797299
z - zi•g
COMMENTS AND NOTES
PRFRRLa3- 8/19/09, 14:00:38 INSPECTION TICKET PAGE 7
Harnett County INSPECTOR: IVR DATE 8/20/09
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOFj:: WY?N CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 60X60 3BDR 2BATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - -
B101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
B103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6/16/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP ,✓105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 MR R*OPEN FLOOR VRU 001764974
6/23/09 AP
E207 01 6/25/09 MR R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001786011
6/25/09 AP provide a premise #
T/S: 06/25/2009 12:30 PM MREARIC
R427 01 7/14/09 BS FOUR TRADE ROUGH IN >2500 VRU 001793611
7/14/09 DA 1. Need engineer to evaluate structural. Point loads from
LVLS carrying floor loads above sitting in open floor spans
unsupported. 2. Trusses in garage max spacing is 16" o.c. -
3. dryer duct too long as installed. 4. Add a receptacle in
front bedroom. Spacing is over 12 Ft. S. No pressure on gas
test. 6.Deck stairs need proper support at bottom.7. LVL
cut sheet calls for 9.5 LVLS, 9.25 installed. OK TO SIDE/
DO NOT INSULATE
R427 02 7/17/09 KS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001795996
7/17/09 DA T/S: 07/16/2009 12:41 PM VBROWN
floor truss in garage that was moved have truss plates
that have separated. Need to get repair or have
manufacturer repress truss plates.
T/S: 07/17/2009 12:36 PM
KSLATTUM
1129 01 7/21/09 MR R*INSULATION INSPECTION VRU 001797281
7/21/09 AP T/S: 07/21/2009 02:27 PM MREARIC
R427 03 7/21/09 MR FOUR TRADE ROUGH IN >2500 VRU 001797299
7/21/09 AP T/S: 07/21/2009 02:27 PM MREARIC
H824 01 8/13/09 JW vENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001809367
CONTINUED ONTO NEXT PAGE
PRIARNUe 8/19/09, 14:00:38 INSPECTION TICKET PAGE 8
Harnett County INSPECTOR: IVR DATE 8120109
- - - - - - - - - - -
ADDRESS . : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR-,. WYTN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- - - - - -
8/13/09 AP T/S: 08/14/2009 11:06 AM SSTEWART
T/S: 08/14/2009 11:07 AM SSTEWART
R431 01 6/20/09 TIn FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001811306
44 A b T/S: 08/19/2009 01:29 PM ROCONTE
- - COMMENTS N TES
~Q Tic 4~-Ot- -Y 1) 1c
Violation Notice
Do Not Remove
Harnett County Inspection Departneent
102 East Front St P.O. Box 65
Lillington, NC 27546
Phone (910) 893-7525 Fax (910) 893-2793
08-50021231 Aug 20, 2009
1. Insulation missing in attic.
2. 2 inch vent not connected in attic.
3. Need screen on upstairs bath vent on gable end wall.
4. Need arc fault breaker on kitchen lights.
$50.00 re-inspection fee
Ken Slattum
PREPARED 6/20/09, 14:36:37 INSPECTION TICKET PAGE 1
Harnett County INSPECTOR: IVR DATE B/21/09
ADDRESS 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR'S WYNN CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: OB-50021231 CP NEW RESIDENTIAL (SFD)
DIRECTIONS : CAMERON PINE DRIVE, CAMERON PINES SUB
DIV #3. 27W, LEFT ON BUFFALO LK RD SUB
DIV 1 MI ON LEFT, ON CAMERON PINE DR
LOT #3.
T/S: 11/12/2008 01:43 PM VBROWN
STRUCTURE: 000 000 6OX60 3BDR 213ATH SFD W GAR CRAWL
FLOOD ZONE . . . . : FLOOD ZONE X
# BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD
SEPTIC - EXISTING? . . . . : SEPTIC WATER SUPPLY . . . . . . . COUNTY
PERMIT: CPSF 00 CP * SFD
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
- -
B101 01 6/11/09 MR R*BLDG FOOTING / TEMP SVC POLE VRU 001780246
6/11/09 AP
B103 01 6/16/09 MR R*BLDG FOUND & TEMP SVC POLE VRU 001782291
6/16/09 AP
A814 01 6/16/09 TW ,DDRESS CONFIRMATION TIME: 17:00 VRU 001782309
6/18/09 AP 105 CAMERON PINES DR LOT 3 SANFORD 27332
B113 01 6/16/09 MR R*BLDG WATER/DAMP PROOFING TIME: 17:00 VRU 001782317
6/16/09 AP
B105 01 6/23/09 MR R*OPEN FLOOR VRU 001764974
6/23/09 AP
E207 01 6/25/09 MR R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001786011
6/25/09 AP provide a premise #
T/S: 06/25/2009 12:30 PM MREARIC
R427 01 7/14/09 BS FOUR TRADE ROUGH IN >2500 VRU 001793611
7/14/09 DA 1. Need engineer to evaluate structural. Point loads from
LVLS carrying floor loads above sitting in open floor spans
unsupported. 2. Trusses in garage max spacing is 16" o.c.
3. dryer duct too long as installed. 4. Add a receptacle in
front bedroom. Spacing is over 12 Ft. 5. No pressure on gas
test. 6.Deck stairs need proper support at bottom.7. LVL
cut sheet calls for 9.5 LVLS, 9.25 installed. OK TO SIDE/
DO NOT INSULATE
R427 02 7/17/09 KS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001795996
7/17/09 DA T/S: 07/16/2009 12:41 PM VBROWN
floor truss in garage that was moved have truss plates
that have separated. Need to get repair or have
manufacturer repress truss plates.
T/S: 07/17/2009 12:36 PM
KSLATTUM
I129 01 7/21/09 MR R*INSULATION INSPECTION VRU 001797281
7/21/09 AP T/S: 07/21/2009 02:27 PM MREARIC
R427 03 7/21/09 MR FOUR TRADE ROUGH IN >2500 VRU 001797299
7/21/09 AP T/S: 07/21/2009 02:27 PM MREARIC
CONTINUED ONTO NEXT PAGE
PREPARED 8/20/09, 14:36:37 INSPECTION TICKET PAGE 2
Harnett County INSPECTOR: IVR DATE 8/21/09
- - - - -
ADDRESS : 105 CAMERON PINES DR SUBDIV: CAMERON PINES 19 LOTS
CONTRACTOR WM CONSTRUCTION, INC. PHONE (919) 528-1347
OWNER WYNN CONSTRUCTION INC PHONE (919) 528-1347
PARCEL 03-9586- - -0024- -41-
APPL NUMBER: 08-50021231 CP NEW RESIDENTIAL (SFD)
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
H824 01 8/13/09 JW ~ ~/E'NVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001809367
8/13/09 AP T/S: 08/14/2009 11:06 AM SSTEWART
T/S: 08/14/2009 11:07 AM SSTEWART
R431 01 8/20/09 FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001811306
8/20/09 DP T/S: 08/19/2009 01:29 PM RDCONTE
1. No attic insulation
2. 2 inch vent not connected in attic -
3. Need screens on upstairs vent on gable end wall -
T/S: 08/20/2009 12:32 PM VBROWN
DISAPPROVED WITH PENT
T/S: 08/20/2009 01:59 PM KSLATTUM
R431 02 8/21/09 TI FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001611650
K,z(, cl' T/S: 08/20/2009 12:39 PM VBROWN
COMMENTS AND NOTES
N p W
w~6r'. ,gyp
imllq s ' onA~1 A((b!r,~$1 ""'fly ~A ~(rRh ' ,ml'~~ Ilf(Mln,~ dAo
„COUNTY OF HARNETT
DEPARTMENT OF BUILDING INSPECTION
AND PLANNING/DEVELOPMENT
CERTIFICATE OF OCCUPANCY
This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building ~~nd
Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in
compliance with the various ordinances of the County of Harnett regulating development and building
_ construction or use. For the following:
Use Classification: 3 PERMIT NUMBERS
c
Owner. it; 21T"1 1 Ic'~ Building Permit No.: ~ - SC,] O Z I Z
t
911 Address: Electrical Permit No.: / r
/ O 5 C n r, c~ Pr t- S Insulation Permit No.: ( t
Ulrp,{t - Plumbing Permit No.: r r
ro State: Zip Code:~ nn / nMach. Permit No.: Al
Date: MFG. Home: ~
Building Official
f
l ,w Zvi w ~ui.40 r_s' ✓ t11 4
A d ~J ~u