Loading...
INSPECTIONS PREPARED 4/24/09, 13:59:28 INSPECTION TICKET PAGE 22 Harnett County INSPECTOR: IVR DATE 4/27/09 ADDRESS . : 191 HAWK LN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - -101 01 4/27/09 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 ci-.7,199 COMMENTS AND NOTES PREPARED 4/27/09, 13:59:36 INSPECTION TICKET PAGE 32 Harnett County INSPECTOR: IVR DATE 4/28/09 ADDRESS 191 HAWK IN SUBDIV: COBxTOCTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 4/27/09 R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule B101 02 14`/288/0099 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001760687 COMMENTS AND NOTES - - - Apr 28 2009 733SAM EGS CHROLINHS 919 861 9911 P.1 - " ECS Carolinas, LLP FIELD REPORT , C Avenue W01 Glenwood RALEIGH, p , RAL NC 27817.7805 Project No. 900 3273992 919 991.9910 (voice) Day/Date T Za L tt AJL0aopaA 919 991-991t ,J(fax) Project 180 NWAlt' rLo- - TempJWeather Location d a rAe , 60061T r g Al(_~ Arrive P P P Al A A V~Q CAVedC~ Depart -_PP~-- p Client 661- 79 4 k On-site Time Travel Time Permits Lab/Office Time Total Time Task Relnapeotlon Time No. of 7Mpa Total Mileage 11 OFGIOE USE ONLY Chargeable Equipment Used Reg. The Overtime i S o it., b ry~,I a ~1 ~s /ZV _Jj r E S a i r^ S eA ~zr VV &'W6 340 " W G ! Lf ~T a-a Cct c7o v r C ! 6" 4o-L, t This report Is preliminary until Wowed by the woneering amfl. Fleld data, IOOROWs, elm!Jons, d depths are eedmetes Copy Received 9y Site Representative ' Prepared By Thwoompeny Bunted Name PREPARED 5/05/09, 13:59:39 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 5/06/09 ADDRESS . : 191 HAWK IN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION - TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - B101 01 4/27/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule B101 02 4/28/09 BS R-BLDG FOOTING / TEMP SVC POLE VRU 001760687 4/28/09 AP Engineering attached. Footing ok to pour, LVL over garage door to be 2-14" w/ 4 studs each end (181) B103 01 5/~ 0 /09 R*BLDG FOUND & TEMP SVC POLE VRU 001764237 - 1`,-- COMMENTS AND NOTES PREPARED 5/12/09, 13:59:45 INSPECTION TICKET PAGE 37 Harnett County INSPECTOR: IVR DATE 5/13/09 - - - - ADDRESS . : 191 HAWK LN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - B101 01 4/27/09 BS R-BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule B101 02 4/28/09 BS R-BLDG FOOTING / TEMP SVC POLE VRU 001760687 4/28/09 AP Engineering attached. Footing ok to pour, LVL over garage door to be 2-14" w/ 4 studs each end (181) B103 01 5106109 KS R*BLDG FOUND & TEMP SVC POLE VRU 001764237 5/06/09 AP B105 01 45/13~/~0~9~ TI_ _ R-OPEN FLOOR VRU 001767083 COMMENTS AND NOTES PREPARED 6/10/09, 13:59:06 INSPECTION TICKET PAGE 16 Harnett County INSPECTOR: IVR DATE 6111109 ADDRESS . : 191 HAWK LN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - -101 01 4/27/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule B101 02 4/28/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760687 4/28/09 AP Engineering attached. Footing ok to pour, LVL over garage door to be 2-14" w/ 4 studs each end (181) B103 01 5/06/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001764237 5/06/09 AP B105 01 5/13/09 BS R*OPEN FLOOR VRU 001767083 5/13/09 AP A814 01 6111109 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001779891 R427 01 6/11/0aA-9~ FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001779883 - - - COMMENTS AND NOTES - PREPARED 6/15/09, 9:54:07 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 6/15/09 - ADDRESS . : 191 HAWK LN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE : (919) 669-7999 OWNER FICK JOHN H PHONE : PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/27/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule 8101 02 4/28/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760687 4/28/09 AP Engineering attached. Footing ok to pour, LVL over garage door to be 2-14" w/ 4 studs each end (18') 8103 01 5/06/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001764237 5/06/09 AP B105 01 5/13/09 BS R*OPEN FLOOR VRU 001767083 5/13/09 AP A814 01 6/11/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001779891 R427 01 6/11/09 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001779883 6/11/09 DA 1. Provide proper uplift on girder and cantilever trusses. 2. Nail girder truss at garage end of house per truss docs. 3. Repair floor joist overnotched at master WC. R427 02 6/15/09 TI FOUR TRADE ROUGH IN >2500 VRU 001781624 1129 01 TI R*INSULATION INSPECTION TIME: 17:00 VRU 001781830 COMMENTS AND NOTES - - PREPARED 7/27/09, 13:58:25 INSPECTION TICKET PAGE 19 Harnett County INSPECTOR: IVR DATE 7/28/09 ADDRESS . : 191 HAWK IN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 4/27/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule B101 02 4/28/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760687 4/28/09 AP Engineering attached. Footing ok to pour, LVL over garage door to be 2-14" w/ 4 studs each end (181) B103 01 5/06/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001764237 5/06/09 AP B105 01 5/13/09 BS R*OPEN FLOOR VRU 001767083 5/13/09 AP A814 01 6/11/09 TW ADDRESS CONFIRMATION TIME: 17:00 VRU 001779891 6/18/09 AP 191 HAWK IN LOT 3 FUQUAY VARINA 27526 R427 01 6/11/09 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001779883 6/11/09 DA 1. Provide proper uplift on girder and cantilever trusses. 2. Nail girder truss at garage end of house per truss docs. 3. Repair floor joist overnotched at master WC. R427 02 6/15/09 BS FOUR TRADE ROUGH IN >2500 VRU 001781624 6/15/09 AP 1129 01 6/15/09 BS R*INSULATION INSPECTION TIME: 17:00 VRU 001781830 6/15/09 AP R431 01 7/1 28/09 09. A kV FOUR TRADE FINAL >2500 VRU 001800697 COMMENTS AND NOTES PREPARED 7/29/09, 14:20:08 INSPECTION TICKET PAGE 12 Harnett County INSPECTOR: IVR DATE 7/30/09 - - - - ADDRESk . : 191 HAWK LN SUBDIV: CONTRACTOR CARROLL LLC, D. PHONE (919) 669-7999 OWNER FICK JOHN H PHONE PARCEL 08-0664- - -0008- -03- APPL NUMBER: 09-50021826 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 401 TOWARD F.V. RIGHT ON CHALYBEATE SPRINGS RD LEFT ON PURFOY RD RD 1/2 MILE ON RIGHT LAST LOT ON LEFT JB STRUCTURE: 000 000 58.6X52.6 3BDR CRAWL. W/ GARAGE FLOOD ZONE . . . . : FLOOD ZONE X / # BEDROOMS . . . . . . . . . PROPOSED USE . . . . . . . SFD SEPTIC - EXISTING? . . . . : EXS WATER SUPPLY . . . . . . . COUNTY PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - -101 01 4/27/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760213 4/27/09 DA Need engineers design on change from front load to side load garage. Need footing sizes (at garage door)and also change of LVL size over garage door. DO NOT POUR. Call to reschedule B101 02 4/28/09 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001760687 4/28/09 AP Engineering attached. Footing ok to pour, LVL over garage door to be 2-14" W/ 4 studs each end (181) B103 01 5/06/09 KS R*BLDG FOUND & TEMP SVC POLE VRU 001764237 5/06/09 AP B105 01 5/13/09 BS R*OPEN FLOOR VRU 001767083 5/13/09 AP A814 01 6/11/09 TW 'ADDRESS CONFIRMATION'i TIME: 17:00 VRU 001779891 6/18/09 AP (-1 1 HAWK LN SHOT '3 FUQUAY VARINA 27526 R427 01 6/11/09 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001779883 6/11/09 DA 1. Provide proper uplift on girder and cantilever trusses. 2. Nail girder truss at garage end of house per truss docs. 3. Repair floor joist overnotched at master WC. R427 02 6/15/09 BS FOUR TRADE ROUGH IN >2500 VRU 001781624 6/15/09 AP 1129 01 6/15/09 BS R*INSULATION INSPECTION TIME: 17:00 VRU 001781830 6/15/09 AP R431 01 7/28/09 BS FOUR TRADE FINAL >2500 VRU 001800697 7/28/09 DA 1. All exterior steps must have max 8 1/4 inch riser at first step. 2. No address posted on structure. 3.A11 non GFCI circuits shall have arc fault protection. 4. Light in master closet too close to storage at ends. 5. Plastic under house must be full coverage, joints lapped 12 inches, cut tight to walls and piers. 6. Where water main shutoff is located under house it must be located within 3 feet of access door. R431 02 7/30/09 T FOUR TRADE FINAL >2500 TIME: 17:00 VRU 001802016 T/S: 07/29/2009 10:50 AM RDCONTE COMMENTS AND NOTES 11711 I&J, III i I., 1 117044 AW 7M COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the fallowing: r ` Use Classification: SFD Conditional Use Permit No.: NA Type of Construction: V Building Permit No.: 09-50021826 Ownerof Building: John H Fick Electrical Permit No.: 09-50021826 Building Address: 191 Hawk Lane Insulation Permit No.: 09-50021826 Zoning District: NA Plumbing Permit No.: 09-50021826 Zoning Permit No.: Nn Mech. Permit No.: 09-50021826 Date: 07-30-09 Envir. C.O. No.: Existing Brad Sutton NA Building Official Zoning Official