INSPECTIONS 2 PREPARED 10/31/07, 14:01:39 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 11/01/07 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E255 01 6/13/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001428614 6/13/07 AP E267 O1 6/20/07 BS C*ELEC TEMP SERVICE POLE VRU 001431535 6/20/07 AP WILL BE FOR THE SITE TRAILER. E259 01 6/27/07 BS C*ELEC UNDER SLAB VRU 001436484 6/27/07 AP for service entry and tele/cable E251 01 7/05/07 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001441286 7/05/07 CA CUSTOMER CALLED IN FOR AN ELECTRICAL INSPECTION ONLY. wrong inspection scheduled E255 02 7/05/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001441583 7/05/07 AP partial feeders (see electrical plan at site) E251 02 7/13/07 TI C*ELEC ROUGH IN TIME: 17:00 VRU 001445832 7/12/07 CA E259 02 7/13/07 LYM C*ELEC UNDER SLAB TIME: 17:00 VRU 001445964 7/13/07 AP E255 03 7/20/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001450790 7/23/07 AP WOULD LIKE THIS INSPECTION AT 9:00 AM. E259 03 8/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001464403 8/10/07 AP E259 04 9/05/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001479765 9/05/07 AP WOULD LIKE THIS IN THE MORNING. area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. E259 05 9/12/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001484708 9/12/07 AP PARTIAL UNDERGROUND. service entrance conduits. E259 06 9/19/07 KS C*ELEC UNDER SLAB TIME: 17:00 VRU 001489202 9/19/07 AP WOULD LIKE THIS IN THE AFTERNOON. E259 07 10/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001502699 10/10/07 AP completed all under slab inspections 10/10/07 E259 08 11/ 1/00'I7 TI C*ELEC UNDER SLAB TIME: 17:00 VRU 001513829 "I~I/7 ASKED FOR AN ELECTRICAL UNDER SLABB RRCUG'HJIN, COMMENTS AND NOTES -E-"-`~' ~J ' PREPARED 11/02/07, 14:03:07 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 11/05/07 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 0800 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 1700 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BE C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GC AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 TI C*PLUMB WATER CONNECTION VRU 001515246 -~~n wg7_ P359 01 11/ /07 C*PLUMB OVERHEAD VRU 001515253 WASTE / VENT CELL BLOCKS A/B/C/D COMMENTS AND NOTES PREPARED 11/06/07, 14:03:17 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 11/07/07 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E255 01 6/13/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001428614 6/13/07 AP E267 01 6/20/07 BE C*ELEC TEMP SERVICE POLE VRU 001431535 6/20/07 AP WILL BE FOR THE SITE TRAILER. E259 01 6/27/07 BS C*ELEC UNDER SLAB VRU 001436484 6/27/07 AP for service entry and tele/cable E251 01 7/05/07 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001441286 7/05/07 CA CUSTOMER CALLED IN FOR AN ELECTRICAL INSPECTION ONLY. wrong inspection scheduled E255 02 7/05/07 BE C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001441583 7/05/07 AP partial feeders (see electrical plan at site) E251 02 7/13/07 TI C*ELEC ROUGH IN TIME: 17:00 VRU 001445832 7/12/07 CA E259 02 7/13/07 LYM C*ELEC UNDER SLAB TIME: 17:00 VRU 001445964 7/13/07 AP E255 03 7/20/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001450790 7/23/07 AP WOULD LIKE THIS INSPECTION AT 9:00 AM. E259 03 8/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001464403 8/10/07 AP E259 04 9/05/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001479765 9/05/07 AP WOULD LIKE THIS IN THE MORNING. area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. E259 05 9/12/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001484708 9/12/07 AP PARTIAL UNDERGROUND. service entrance conduits. E259 06 9/19/07 KS C*ELEC UNDER SLAB TIME: 17:00 VRU 001489202 9/19/07 AP WOULD LIKE THIS IN THE AFTERNOON. E259 07 10/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001502699 10/10/07 AP.9 completed all under slab inspections 10/10/07 E259 08 11/01/07 T,I~., C*ELEC UNDER SLAB TIME: 17:00 VRU 001513829 ,'J/1, iP/~yl-SQ3)~- ASKED FOR AN ELECTRICAL UNDER SLAB ROUGH .IN. E255 04 11/07/07 IT ` C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001516814 1 THIS WILL BE FOR THE OUTSIDE LIGHT POLES. PLEASE GO AS EARLY AS POSSIBLE**********x************************** COMMENTS AND NOTES PREPARED 11/07/07, 15:38:30 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 11/08/07 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNET COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E255 01 6/13/07 BE C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001428614 6/13/07 AP E267 01 6/20/07 BS C*ELEC TEMP SERVICE POLE VRU 001431535 6/20/07 AP WILL BE FOR THE SITE TRAILER. E259 01 6/27/07 BS C*ELEC UNDER SLAB VRU 001436484 6/27/07 AP for service entry and tele/cable E251 01 7/05/07 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001441286 7/05/07 CA CUSTOMER CALLED IN FOR AN ELECTRICAL INSPECTION ONLY. wrong inspection scheduled E255 02 7/05/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001441583 7/05/07 AP partial feeders (see electrical plan at site) E251 02 7/13/07 TI C*ELEC ROUGH IN TIME: 17:00 VRU 001445832 7/12/07 CA E259 02 7/13/07 LYM C*ELEC UNDER SLAB TIME: 17:00 VRU 001445964 7/13/07 AP E255 03 7/20/07 BE C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001450790 7/23/07 AP WOULD LIKE THIS INSPECTION AT 9:00 AM. E259 03 8/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001464403 8/10/07 AP E259 04 9/05/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001479765 9/05/07 AP WOULD LIKE THIS IN THE MORNING. area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. E259 05 9/12/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001484708 9/12/07 AP PARTIAL UNDERGROUND. service entrance conduits. E259 06 9/19/07 KS C*ELEC UNDER SLAB TIME: 17:00 VRU 001489202 9/19/07 AP WOULD LIKE THIS IN THE AFTERNOON. E259 07 10/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001502699 10/10/07 AP completed all under slab inspections 10/10/07 E259 08 11/01/07 BE C*ELEC UNDER SLAB TIME: 17:00 VRU 001513829 11/07/07 AP ASKED FOR AN ELECTRICAL UNDER SLAB ROUGH IN. upstairs slab section a E255 04 11/07/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001516814 11/07/07 AP THIS WILL BE FOR THE OUTSIDE LIGHT POLES. PLEASE GO AS EARLY AS POSSIBLE************************************* parking lot lights north and west side of sight E255 05 11/08/07 TI C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001518083 1t-tLej '4 WILL BE FOR THE POLE BASES. COMMENTS AND NOTES PREPARED 12/06/07, 15:42:44 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 12/07/07 -_____________c________----_______________ ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8/15/07 AP C159 01 8/17/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001469584 8/17/07 AP AREA B area "b" slab C161 01 9/04/07 BS C*MONOLITH SLAB VRU 001478916 9/04/07 AP WOULD LIKE INSPECTION IN THE MORNING patial area "A"slab. See plan for detail C159 03 9/05/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001480417 9/05/07 AP area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. C159 04 9/25/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001492974 9/25/07 AP AREA "C" C159 05 10/10/07 TI C*BLDG SLAB INSP TIME: 17:00 VRU 001502400 10/10/07 CA WILL BE THE ELECTRICAL UNDER THE SLAB. C159 06 10/12/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001503499 10/12/07 AP THIS WILL BE FOR AREA A area "A" final slab ground floor MISC 01 10/19/07 KS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001507615 10/19/07 AP WASTE AND VENT INSPECTION AREAS B,C,D. MISC 02 10/24/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001509942 10/24/07 AP WILL BE A WASTE AND VENT INSPECTION IN AREAS C AND D. C159 07 11/01/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001513936 11/07/07 AP WILL BE FOR A SUSPENDED SLAB AREA "A" OVER THE CELL BLOCK. upstairs slab section a C167 01 12~/0~7/~0f7 TI C *WALL INSPECTION TIME: 17:00 VRU 001532100 WILL BE A WALL INSPECTION FOR AREAS - PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS _ C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 0800 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 1700 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 1700 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND _ PREPARED 12/06/07, 15:42:44 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 12/07/07 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL . 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering mech room P359 01 11/05/07 BS C*PLUMB OVERHEAD VRU 001515253 11/05/07 AP. WASTE / VENT CELL BLOCKS A/B/C/D MISC 01 1l2/07/'07 TI COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001532118 WILL BE A WASTE AND VENT INSPECTION FOR AREA C. COMMENTS AND NOTES PREPARED 1/11/08, 14:01:25 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 1/14/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU#: 001445634 7/13/07 AP . P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME:.17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM' DJOHNSON P357 08- 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering mech room P359 01 11/05/07 BS C*PLUMB OVERHEAD VRU 001515253 11/05/07 AP WASTE / VENT CELL BLOCKS A/B/C/D MISC 01 12/07/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001532118 12/07/07 AP WILL BE A WASTE AND VENT INSPECTION FOR AREA C. plumbing dist in wall pressure tests areas bcd P351 04 1/1 /08 TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001546860 ~ WASTE AND VENT IN AREA C P359 02 1/ 9/08 C*PLUMB OVERHEAD TIME: 17:00 VRU 001546878 OVERHEAD IN AREA D. PREPARED 1/25/08, 8:45:50 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 1/25/08 ADDRESS . : 55409 'UNASSIGNED SUBDIV: COUNTY OF HARNETT_ CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAI L-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8/15/07 AP C159 01 8/17/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001469584 8/17/07 AP AREA B area "b" slab C161 01 9/04/07 BS C*MONOLITH SLAB VRU 001478916 9/04/07 AP WOULD LIKE INSPECTION IN THE MORNING patial area "A"slab. See plan for detail C159 03 9/05/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001480417 9/05/07 AP area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. C159 04 9/25/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001492974 9/25/07 AP AREA "C" C159 05 10/10/07 TI C*BLDG SLAB INSP TIME: 17:00 VRU 001502400 10/10/07 CA WILL BE THE ELECTRICAL UNDER THE SLAB. C159 06 10/12/07 BS -*BLDG SLAB INSP TIME: 17:00 VRU 001503499 10/12/07 AP THIS WILL BE FOR AREA A area "A" final slab ground floor MISC 01 10/19/07 KS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001507615 10/19/07 AP WASTE AND VENT INSPECTION AREAS B,C,D. MISC 02 10/24/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001509942 10/24/07 AP WILL BE A WASTE AND VENT INSPECTION IN AREAS C AND D. C159 07 11/01/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001513936 11/07/07 AP WILL BE FOR A SUSPENDED SLAB AREA "A" OVER THE CELL BLOCK. upstairs slab section a C167 01 12/07/07 BS C*WALL INSPECTION TIME: 17:00 VRU 001532100 12/07/07 CA WILL BE A WALL INSPECTION FOR AREA B wrong inspection called in C159 1/25/08 TI C*BLDG SLAB INSP TIME: 17:00 VRU 00155222 1p p ~3 Og Lyle SUSPENDED FLOOR SLAB FOR AREA A. a W 0 ~~~~L 0 m ~a A-F * c C165 01 1/25/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001552207 1/25 8 CA ROOF DRAIN. PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 0800 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 1700 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 1700 VRU 001451251 7/23/07 AP Warts inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 PREPARED 1/28/08, 14:13:53 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 1/29/08 - - - - ADDRESS • :`55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- `~i (INS APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB i % - - STRUCTURE: 000 000 JAIL/DETENTION K LAN ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : JAIL SEPTIC - EXISTING? . . . . SEWE PERMIT: CBCO 00 CP BUILDING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C151 01 6/07/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001425297 6/07/07 AP partial footing C151 02 6/12/07 BS C*BLDG FOOTING TIME: 08:00 VRU 001427822 6/12/07 AP C151 03 6/18/07 TI C*BLDG FOOTING TIME: 17:00 VRU 001430610 6/18/07 CA WOULD LIKE THIS INSPECTION AROUND 11:00 TO 11:30. C151 04 6/19/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001430909 6/19/07 AP WOULD LIKE THIS INSPECTION AROUND 9:00 OR 9:30. C151 05 6/27/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001436468 6/27/07 AP WOULD LIKE THIS INSPECTION AT 9:00 AM. area A partial C151 06 6/29/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001438399 6/29/07 AP WOULD LIKE THIS INSPECTION AT 9 AM. IT WILL BE FOR AREA A. section a partial C151 07 7/05/07 BS C*BLDG FOOTING TIME: 08:00 VRU 001441294 7/05/07 AP section a/b center area C151 08 7/11/07 LYM C*BLDG FOOTING TIME: 17:00 VRU 001444173 7/11/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. v. C151 09 7/13/07 LYM C*BLDG FOOTING TIME: 17:00 VRU 001445626 7/13/07 AP C151 10 7/18/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001448851 7/18/07 AP WOULD LIKE THIS INSPECTION IN THE MORNING. C151 11 7/19/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001449883 7/23/07 AP prefers AM. C151 12 7/24/07 TI C*BLDG FOOTING TIME: 17:00 VRU 001452473 7/25/07 AP WOULD LIKE THIS AT 9:00 per brad C151 13 7/25/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001453950 7/25/07 CA per contractor C151 14 7/26/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001455229 7/26/07 AP C151 15 7/30/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001456466 7/30/07 AP WOULD LIKE THIS AT 9:00 AM. C151 16 7/31/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001457407 8/01/07 AP WOULD LIKE THIS AT 9:00 AM. C151 17 8/03/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001460062 8/03/07 AP WOULD LIKE THIS AT 9:00 AREA A C159 02 8/05/07 TI C*BLDG SLAB INSP TIME: 17:00 VRU 001480409 9/05/07 CA WILL BE IN AREA D C151 18 8/08/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001462969 8/08/07 AP C151 19 8/09/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001463744 8/09/07 AP WILL BE FOR AREA C. WOULD LIKE YOU TO GO AROUND 9:00. C151 20 8/14/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001466804 8/14/07 AP C151 21 8/15/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001467596 PREPARED 1/28/08, 14:13:53 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 1/29/08 ADDRESS :'55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8/15/07 AP C159 01 8/17/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001469584 8/17/07 AP AREA B area "b" slab C161 01 9/04/07 BS C*MONOLITH SLAB VRU 001478916 9/04/07 AP WOULD LIKE INSPECTION IN THE MORNING patial area "A"slab. See plan for detail C159 03 9/05/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001480417 9/05/07 AP area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. C159 04 9/25/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001492974 9/25/07 AP AREA "C" C159 05 10/10/07 TI C*BLDG SLAB INSP TIME: 17:00 VRU 001502400 10/10/07 CA WILL BE THE ELECTRICAL UNDER THE SLAB. C159 06 10/12/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001503499 10/12/07 AP THIS WILL BE FOR AREA A area "A" final slab ground floor MISC 01 10/19/07 KS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001507615 10/19/07 AP WASTE AND VENT INSPECTION AREAS B,C,D. MISC 02 10/24/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001509942 10/24/07 AP WILL BE A WASTE AND VENT INSPECTION IN AREAS C AND D. C159 07 11/01/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001513936 11/07/07 AP WILL BE FOR A SUSPENDED SLAB AREA "A" OVER THE CELL BLOCK. upstairs slab section a C167 01 12/07/07 BS C*WALL INSPECTION TIME: 17:00 VRU 001532100 12/07/07 CA WILL BE A WALL INSPECTION FOR AREA B wrong inspection called in C159 08 1/25/08 LYM C*BLDG SLAB INSP TIME: 17:00 VRU 001552223 1/25/08 AP SUSPENDED FLOOR SLAB FOR AREA A. FINAL SLAB POUR- 2ND. FLOOR ADMIN. C165 01 1/25/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001552207 1/25/08 CA ROOF DRAIN. C165 02 1/29/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001552934 1Q b WILL BE FOR THE ROOF DRAIN.**************************** - CONTINUED ONTO NEXT PAGE - - - PREPARED 1/28/08, 14:13:53 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 1/29/08 - - - ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : JAIL SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering mech room P359 01 11/05/07 BS C*PLUMB OVERHEAD VRU 001515253 11/05/07 AP WASTE / VENT CELL BLOCKS A/B/C/D MISC 01 12/07/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001532118 12/07/07 AP WILL BE A WASTE AND VENT INSPECTION FOR AREA C. plumbing dist in wall pressure tests areas bcd P351 04 1/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001546860 1/14/08 AP WASTE AND VENT IN AREA C waste and vent tests @ 5 psi air and holding P359 02 1/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001546878 PREPARED 1/28/08, 14:13:53 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 1/29/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER SAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1/14/08 AP OVERHEAD IN AREA D. waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 TC*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 A WILL BE AREA D WASTE AND VENT PIPE.************ COMMENTS AND NOTES PREPARED 1/29/08, 14:00:39 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 1/30/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.************ P359 05 1/~30/~~~~~0,••••ij'''~►►►►8 TI g$ C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 j MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. N,iT COMMENTS AND NOTES PREPARED 2/05/08, 14:01:24 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 2/06/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. 2359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.************ P359 05 1/30/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 1130108 AP MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. NJT P351 05 2/06/08 TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001558659 Q PLUMBING OVERHEAD ROUGH IN AREA D P359 06 2f06/08 T C*PLUMB OVERHEAD TIME: 17:00 VRU 001558642 PLUMBING ROOF DRAIN AREA B********************************* COMMENTS AND NOTES LAURENE & RICKNERa P.C. Cmsuling Slruclral Engineers February 7, 2008 Mr. Dan Mace, AIA Moseley Architects 11430 North Community House Road Suite 225 Charlotte, NC 28277 RE: Harnett County Law Enforcement Center Lillington, NC Dear Dan: Last week while the contractor was pouring the concrete slab on metal deck he called us stating that they were experiencing some steel beam deflection. Immediately upon receiving this call we reviewed our design and analysis of the building. We found that camber to compensate for the dead load deflection (i.e. wet concrete weight) of the beams was not shown on the structural drawings. The beams were fabricated and erected flat. The as-constructed framing exhibits the deflection for which these beams could have been cambered. While this has led to the beams deflecting, the floor (i.e. concrete slab) has been finished to the required flatness and levelness and all beams, columns and connections have the capacity required by the North Carolina State Building Code. The structural integrity of the building has not been compromised by this issue. Please call me with any questions or comments. Sincerely, ueannnerq LAURENE & RICKHER, P.C. `„3 t9 ( 9 '"L e ~ ~ L rt v= Mark S. Rickher, PE 1546(~ Principal V•,F/Y f W a cc: Chris Moore - Moseley Architects (by email only) Duane Sirhal - Moseley Architects (by email only) File Suite 500 1 9701 Red Oak 9eWevard / CludIXt4 ne 28117 Td: Mul5 .Ne5 t F6a: 7N.522.0499 / E-Mar: clWdulle®kpc.nal Page 1 of 2 Lynwood Mcdonald From: Lynwood Mcdonald Sent: Tuesday, February 12, 2008 12:29 PM To: Neil Emory Subject: RE: Harnett Neil, I do not feel totally comfortable concerning the deflection of the steel with just this letter. I understand why it deflected without the camber added to all the beams. It certainly looks worse than it is, however we have additional dead load weight and live load to be added (furniture and employees) on the second floor when the building is completed. I would feel more comfortable if another structural engineer reviewed the drawings and inspected the steel at the site from a separate firm. I expressed to Tony Steve Fleming, from Fayetteville was mighty good. Steve is one of the best structural engineers in this area. Steve does a lot of work for T.A Loving and Campbell U. Thanks, Lynwood -----Original Message----- From: Neil Emory Sent: Tuesday, February 12, 2008 10:34 AM To: Lynwood Mcdonald Subject: FW: Harnett Lynwood, Are you comfortable with this? Neil -----Original Message----- From: Tony Wilder Sent: Monday, February 11, 2008 1:59 PM To: Neil Emory Subject: FW: Harnett Neil, Here's the letter from the Structural Engineer. tw Wm. A. (Tony) Wilder, Asst. County Manager County of Harnett P. O. Box 759 Lillington, NC 27546 910-893-7555 910-814-2662 (fax) Harnett couNrr t111 1ti raagL;5x strong roots • new growth -----Original Message----- From: Sirhal, Duane [mailto:dsirhal@moseleyarchitects.com] Sent: Monday, February 11, 2008 1:54 PM 2/12/2008 Page 2 of 2 To: Tony Wilder Cc: Lynwood Mcdonald; Tom Bordeaux; Milton Boyette; Mace, Dan; Palmieri, Jim; Moore, Chris; Mark Rickher Subject: FW: Harnett Tony, To address any concerns, attached is the letter from Mark Rickher of Laurene & Rickher dated 217108 regarding the structural steel issue and indicating that the structural steel has the capacity required by the North Carolina State Building Code and that the structural integrity of the building has not been compromised. Thanks, Duane A. Sirhal, AIA Construction Administrator MOSELEY ARCHITECTS Architecture. Engineering. Interiors. Planning Gibson Building, Suite 225 11430 North Community House Road Charlotte, NC 28277 704.540.3755 FAX 704:540.3754 W W W. MOSELEYARCHITECTS. COM From: Mark Rickher [mailto:mrickher@lrpc.net] Sent: Monday, February 11, 2008 9:43 AM To: Mace, Dan Cc: Sirhal, Duane; Palmieri, Jim Subject: Harnett Dan: Here is a pdf copy of the letter regarding the slab issue. Regards, Mark S. Rickher, PE Principal LAURENE & RICKHER, P.C. Consulting Structural Enginmrs 8701 Red Oak Boulevard Suite 500 Charlotte, NC 28217 T: 704.522.0495 F: 704.522.D499 Direct: 980-235-2624 E: mrickher@irpc.net 2/12/2008 01 080 3 2703 Harnett County Planning HARNETT CO. PLANNING SERVICES 084225 02 12 2008 3 /8 4arnet;- County 1AbkSUTXON TICKET PAGE INSPECTOR: IVR DATE 2/12 _ ADDRESS 55409 *UNASSIGNED CONTRACTOR BORDEAUX CONSTRUCTION CO INC SUBDIV; COUNTY OF HARNETT OWNER JAIL-HARNETT COUNTY OF PHONE (919) 220-1141 PARCEL 11-0650- - PHONE -0008- -pl- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS ; ADJACENT TO EXISTING COURTHOUSE TB STRUCTURE: 000 000 JAIL D / BTB~IOIi 6, LAN ENPORCBi~T FLOOD ZONE . . . . : FLOOD ZONE X CMMM PROPOSED USE . . . JAIL - SEPTIC - EXISTING? . • SEWER PERlQT: CBCO 00 CP BUILD314G COMMERCIAL - REQUESTED- INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C151 pl. 6/07/07 BS C* BLDG FOOTING ___TIME____:___-17:--00------------------------------------- 6/07/07 AP partial footing VRU 001425297 C151 02 6/12/07 BS C*BLDG FOOTING TIME; 08:00 6/12/07 AP VRU 00I427822 C151 03 6/18/07 TI C*BLDG FOOTING TIME; 17:00 VRU 001430610 6/18/07 CA WOULD LIKE THIS C151 04 6/19/07 BS INSPECTION AROUND 11:00 TO 11:30. C*BLDG FOOTING 6/19/07 TIME: 17:00 VRU 001430909 AP WOULD LIKE THIS INSPECTION AROUND 9:00 OR 9:30. C151 05 6/27/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001436468 6/27/07 AP WOULD LIKE THIS INSPECTION AT 9:00 AM. area A partial 06 6/29/D7 BS C*SLDG FOOTING TIME; 17:00 VRU 001438399 6/29/07 AP WOULD LIKE THIS INSPECTION AT 9 AM. IT WILL BE FOR AREA A. 0151 07 7 section a partial /05/07 BS C*BLDG FOOTING TIME: 08:00 7/05/07 AP section a/b center area VRU 001441294 C151 08 7/11/07 LYM C*BLDG FOOTING TIME: 17:00 VRU 001444173 7/11/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. C151 09 7/13/07 LYN C*BLDG FOOTING TIME: 17;00 VRU 001445626 7/13/07 AP C151 10 7/18/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001448851 7/18/07 AP WOULD LIKE THIS INSPECTION IN THE MORNING. C151 ll 7/19/07 BS C*BLDG FOOTING TIME: 17:00 VRU 7/23/07 AP 001449883 P 0151 12 7/24/07 TI prefers AM. C *BLDG FOOTING TIME: 17:00 VRU 001452473 7/25/07 AP WOULD LIKE THIS AT 9:00 Per brad CZ51 13 7/25/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001453950 7/25/07 CA per contractor C151 14 7/26/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001455229 7/26/07 AP C151 15 7/30/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001456466 7/30/07 AP WOULD LIKE THIS AT 9:00 AM. (7151 16 7/31/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001457407 8/01/07 AP WOULD LIKE THIS AT 9:00 AM. C151 17 8/03/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001460062 8/03/07 AP WOULD LIKE THIS AT 9:00 AREA A C159 02 8/05/07 TI C*BLDG SLAB INSP TIME: 17:00 VRU 001480409 9/05/07 CA WILL BE IN AREA D C151 18 8/08/07 BS C*BLDG FOOTING TIME: 17:00 8/08/07 AP VRU 001462969 i 7151 19 8/09/07 BS C*BLDG FOOTING TIME: 17:00 VRU 001463744 8/09/07 AP WILL BE FOR AREA C. WOULD LIKE YOU TO GO AROUND 9:00. '151 20 8/14/07 85 C*BLDG FOOTING TIME: 17:00 8/14/07 AP YRU 001466604 '151 21 8/15/07 BS C*BLDG FOOTING TIME: 17;00 VRtt @- nm ncoc- PREPARED 2/12/08, 10:33:27 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/12/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 SS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering mech room P359 01 11/05/07 BE C*PLUMB OVERHEAD VRU 001515253 11/05/07 AP WASTE / VENT CELL BLOCKS A/B/C/D MISC 01 12/07/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001532118 12/07/07 AP WILL BE A WASTE AND VENT INSPECTION FOR AREA C. plumbing dist in wall pressure tests areas bcd P351 04 1/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001546860 1/14/08 AP WASTE AND VENT IN AREA C waste and vent tests @ 5 osi air and holding P359 02 1/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001546878 0108032703 Harnett County Planning HARNETT CO. PLANNING SERVICES 0843:10 02 12 2008•. Vy 4 /8 E Harnett County INSPECTOR: IVR DATE E ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SO COMPLETED RESULT RESULTS/COMMENTS 8/15/07 AP C159 01 8/17/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001469584 8/17/07 AP AREA B area "b" slab C161 01 9/04/07 BS C*MONOLITH SLAB VRU 001478916 9/04/07 AP WOULD LIKE INSPECTION IN THE MORNING patial area "A"slab. See plan for detail C159 03 9/05/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001480417 9/05/07 AP area "d" slab. Inspection also called for underalab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. C159 04 9/25/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001492974 9/25/07 AP AREA "C" C159 05 10/10/07 TI C•BLDO SLAB INSP TIME: 17:00 VRU 001502400 10/10/07 CA WILL BE THE ELECTRICAL UNDER THE SLAB. C159 06 10/12/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001503499 10/12/07 AP THIS WILL BE FOR AREA A area "A" final slab ground floor \ MISC 01 10/19/07 KS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001507615 10/19/07 AP WASTE AND VENT INSPECTION AREAS B,C,D.~ MISC 02 10/24/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001509942 10/24/07 AP WILL BE A WASTE AND VENT INSPECTION IN AREAS C AND D. C159 07 11/01/07 BS C*BLDG SLAB INSP TIME: 17:00 VRU 001513936 11/07/07 AP WILL BE FOR A SUSPENDED SLAB AREA "A" OVER THE CELL BLOCK. upstairs slab section a C167 01 12/07/07 BS C*WALL INSPECTION TIME: 17:00 VRU 001532100 12/07/07 CA WILL BE A WALL INSPECTION FOR AREA B wrong inspection called in 0159 08 1/25/08 LYN C-BLDG SLAB INSP TIME: 17:00 VRU 001552223 1/25/08 AP SUSPENDED FLOOR SLAB FOR AREA A. FINAL SLAB POUR- 2ND. FLOOR ADMIN. C165 01 1/25/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001552207 \ 1/25/08 CA ROOF DRAIN. C165 02 1/29/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001552934 1/29/08 AP WILL BE FOR THE ROOF DRAIN.****++t++**++++++********+*♦ C165 03 1/31/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001555705 1/31/08 CA WILL BE FOR A ROOF DRAIN IN AREA B. C165 04 2/12/08 TI C-OVERHEAD FOR BUILDING VRU 001561646 building A overhead CONTINUED ONTO NEXT PAGE 1~~ PREPARED 2/12/08, 10:33:27 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 2/12/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1/14/08 AP OVERHEAD IN AREA D. waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.******'***** P359 05 1/30/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 1/30/08 AP MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. NJT P351 05 2/06/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001558659 2/06/08 AP PLUMBING OVERHEAD ROUGH IN AREA D ************x*******F**** P359 06 2/06/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001558642 2/06/08 AP PLUMBING ROOF DRAIN AREA B********************************* MISC 02 2 12108 TI COMMERCIAL MISCELLANEOUS VRU 001561638 D. ? roof drains in area D (didnt know what to schedule) P359 07 2/12/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001562156 COMMENTS AND NOTES PREPARED 2/13/08, 15:57:45 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/14/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : 'JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION &LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 - / 1- ✓ C*MECH DUCT TIME: 17:00 VRU 001563378 ~J PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering mech room P359 01 11/05/07 BS C*PLUMB OVERHEAD VRU 001515253 11/05/07 AP WASTE / VENT CELL BLOCKS A/B/C/D PREPARED 2/13/08, 15:57:45 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 2/14/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS MISC 01 12/07/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001532118 12/07/07 AP WILL BE A WASTE AND VENT INSPECTION FOR AREA C. plumbing dist in wall pressure tests areas bcd P351 04 1/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001546860 1/14/08 AP WASTE AND VENT IN AREA C waste and vent tests @ 5 psi air and holding P359 02 1/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001546878 1/14/08 AP OVERHEAD IN AREA D. waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.************ P359 05 1/30/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 1/30/08 AP MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. NJT P351 05 2/06/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001558659 2/06/08 AP PLUMBING OVERHEAD ROUGH IN AREA D P359 06 2/06/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001558642 2/06/08 AP PLUMBING ROOF DRAIN AREA B********************************* MISC 02 2/12/08 BS COMMERCIAL MISCELLANEOUS VRU 001561638 2/12/08 AP roof drains in area D (didnt know what to schedule) P359 07 2/12/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001562156 2/12/08 AP P351 06 2/14/08 TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001563360 /~LtAl WILL BE A VENT PIPING AND OVERHEAD AREA C rN~~ 4 ✓A-ul~yi1 774 c P359 08 2/34/08 Tj, C*PLUMB OVERHEAD TIME: 17:00 VRU 00g156q33 -Z t~ -i/-'LIBLi < - j ue.2/1 c a.cz~6./~as COMMENTS AND NOTES //2-z4,-5 Page 1 of l Lynwood Mcdonald From: Tony Wilder Sent: Monday, February 18, 2008 9:13 AM To: Sirhal, Duane Cc: Lynwood Mcdonald; Neil Emory Subject: Structural Evaluation Duane, Please proceed with contacting Steve Fleming, Structural Engineer in Fayetteville, for a second opinion concerning the deflection of the steel beams supporting the second floor at the Detention Center under construction. It is my understanding that Mr. Fleming will provide an opinion based on NC Building code and costs will not exceed $2,500. Wm. A. (Pony) Wilder, Asst. County Manager County of Harnett P. O. Box 759 Lillington, NC 27546 910-893-7555 910-814-2662(fax) Harnett COA N T Y +oFni CAIctu. strong roots • new growth 2/18/2008 PREPARED 3/11/08, 15:32:42 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 3/12/08 ADDRESS . :_'55409-*UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE :'(919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1/14/08 AP OVERHEAD IN AREA D. waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.************ P359 05 1/30/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 1/30/08 AP MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. NJT P351 05 2/06/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001558659 2/06/08 AP PLUMBING OVERHEAD ROUGH IN AREA D *****"*******x********** P359 06 2/06/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001558642 2/06/08 AP PLUMBING ROOF DRAIN AREA B************'*******x*********~*° N,ISC 02 2/12/08 BS COMMERCIAL MISCELLANEOUS VRU 001561638 2/12/08 AP roof drains in area D (didnt know what to schedule) P359 07 2/12/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001562156 2/12/08 AP P351 06 2/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001563360 2/14/08 CA WILL BE A VENT PIPING AND OVERHEAD AREA C P359 08 2/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001563352 2/14/08 AP ?~.b P351 07 3/12/08 TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001576016 3- • ofd A ROOF DRAIN AREA D. P359 10 3/12/08 TI .rGsn. &*PLUMB OVERHEAD TIME: 17:00 VRU 001576032 3-1.2-o$ LX l WILL BE FOR THE PLUMBING ABOVE THE CEILING IN THE KITCHEN. P359 09 3/12/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001575729 3/11/08 CA -s ec-f 4 COMMENTS AND NOTES L o ,Z3 ~m A/? °Eo s ~ ® k a J !G P n) -y OV 1lru N-~ ! 13 '7v'0, `7 " W 07/-b ~j GL rFb ~ 1 ~ 3 ~h(~JdV,~?~uat sJ•JYs ~,~~7~.✓G ~nkp p PREPARED 3/13/08, 14:16:31 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 3/14/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 T~ _ C*MECH DUCT TIME: 17:00 VRU 001577162 fL Cp~1/JI~dLT]5 WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA -------------------------------1~-" PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00_ partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BE C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BE C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering meth room P359 01 11/05/07 BS C"PLUMB OVERHEAD VRU 001515253 PREPARED 3/13/08, 14:16:31 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 3/14/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER . . . J`i L-HARNETT COUNTY OF PHONE PARCEL . . : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 11/05/07 AP WASTE / VENT CELL BLOCKS A/B/C/D MISC 01 12/07/07 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001532118 12/07/07 AP WILL BE A WASTE AND VENT INSPECTION FOR AREA C. plumbing dist in wall pressure tests areas bcd P351 04 1/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001546860 1/14/08 AP WASTE AND VENT IN AREA C waste and vent tests @ 5 psi air and holding P359 02 1/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001546878 1/14/08 AP OVERHEAD IN AREA D. waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.*******-**** P359 05 1/30/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 1/30/08 AP MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. NJT 2351 05 2/06/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001558659 2/06/08 AP PLUMBING OVERHEAD ROUGH IN AREA D P359 06 2/06/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001558642 2/06/08 AP PLUMBING ROOF DRAIN AREA B********************************* MISC 02 2/12/08 BS COMMERCIAL MISCELLANEOUS VRU 001561638 2/12/08 AP roof drains in area D (didnt know what to schedule) P359 07 2/12/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001562156 2/12/08 AP P351 06 2/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001563360 2/14/08 CA WILL BE A VENT PIPING AND OVERHEAD AREA C P359 08 2/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001563352 2/14/08 AP P351 07 3/12/08 LYM C*PLUMB ROUGH IN TIME: 17:00 VRU 001576016 3/12/08 AP ROOF DRAIN AREA D. P359 10 3/12/08 LYM C*PLUMB OVERHEAD TIME: 17:00 VRU 001576032 3/12/08 AP WILL BE FOR THE PLUMBING ABOVE THE CEILING IN THE KITCHEN. TESTED PER LYM. 03/12/08 KITCHEN AND SHOWER SECTION "D" *100 PSI 2 AREARS IN KITCHEN EVERYTHING EXCEPT MAIN PIPING WATER DISTRIBUTION. -ROOF DRAIN MENS 40 BED AREA AND MECHANICAL ROOM. ROOF TEST WATER FILLED AND BOTTOM SIDE. *INDIVUDUAL SINKS VENTING AREA "D" P359 09 3/12/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001575729 3/11/08 CA MISC 03 3/14/08 TI COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001577154 (('b4 RgS WILL BE FOR THE WASTE AND VENT DRAINS IN AREA C. P359 11 /1 /08 TI, C*PLUMB OVERHEAD TIME: 17:00 VRU 001577147 COMMENTS AND NOTES PREPARED 3/17/08, 14:51:59 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 3/18/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1/14/08 AP OVERHEAD IN AREA D. waste vent and distribution for kitchen area / laundry area tested at 5 psi for dwv, 100 psi and above for dist. P359 03 1/25/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001552215 1/25/08 CA AREA D WASTE AND VENT PIPE. P359 04 1/29/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001552959 1/29/08 AP WILL BE AREA D WASTE AND VENT PIPE.************ P359 05 1/30/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001554609 1/30/08 AP MILTON WANTS 3 OVERHEAD PLUMBING INSPECTIONS IN AREA B FOR WEDNESDAY AM. NJT P351 05 2/06/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001558659 2/06/08 AP PLUMBING OVERHEAD ROUGH IN AREA D P359 06 2/06/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001558642 2/06/08 AP PLUMBING ROOF DRAIN AREA B********************************* MISC 02 2/12/08 BS COMMERCIAL MISCELLANEOUS VRU 001561638 2/12/08 AP roof drains in area D (didnt know what to schedule) P359 07 2/12/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001562156 2/12/08 AP P351 06 2/14/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001563360 2/14/08 CA WILL BE A VENT PIPING AND OVERHEAD AREA C P359 08 2/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001563352 2/14/08 AP P351 07 3/12108 LYM C*PLUMB ROUGH IN TIME: 17:00 VRU 001576016 3/12/08 AP ROOF DRAIN AREA D. P359 10 3/12/08 LYM C*PLUMB OVERHEAD TIME: 17:00 VRU 001576032 3/12/08 AP WILL BE FOR THE PLUMBING ABOVE THE CEILING IN THE KITCHEN. TESTED PER LYM. 03/12/08 KITCHEN AND SHOWER SECTION "D" *100 PSI 2 AREARS IN KITCHEN EVERYTHING EXCEPT MAIN PIPING WATER DISTRIBUTION. *ROOF DRAIN MENS 40 BED AREA AND MECHANICAL ROOM. ROOF TEST WATER FILLED AND BOTTOM SIDE. *INDIVUDUAL SINKS VENTING AREA "D" P359 09 3/12/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001575729 3/11/08 CA MISC 03 3/14/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001577154 3/14/08 AP WILL BE FOR THE WASTE AND VENT DRAINS IN AREA C. P359 11 3/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001577147 3/14/08 AP P359 12 3/18/08 TINS & C*PLUMB OVERHEAD TIME: 17:00 VRU 001578921 ~3J_OQ oifVJ WILL BE A ROOF DRAIN INSPECTION FOR AREAS "C" AND "D". COMMENTS AND NOTES PREPARED 3/19/08, 14:06:59 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 3/20/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 TI SS C*MECH DUCT TIME: 17:00 VRU 001580455 WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". ,E PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BE C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 PREPARED 3/19/08, 14:06:59 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 3/20/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY CF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYF/SQ COMPLETED RESULT RESULTS/COMMENTS 3/14/08 AP P359 12 3/18/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001578921 3/18/08 AP WILL BE A ROOF DRAIN INSPECTION FOR AREAS "C" AND "D". P359 13 3/20/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001580653 SQS WILL BE FOR A PLUMBING RCCF DRAIN INSPECTICN FOR ARFA "C". COMMENTS AND NOTES PREPARED 3/25/08, 14:00:51 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 3/26/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BE C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 IR~ C*MECH DUCT TIME: 17:00 VRU 001582964 A14010 WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BE C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER'SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 PREPARED 3/25/08, 14:00:51 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 3/26/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HP.RNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS MISC 03 3/14/08 BE COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001577154 3/14/08 AT WILL BE FOR THE WASTE AND VENT DRAINS IN AREA C. P359 11 3/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001577147 3/14/08 AP P359 12 3/18/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001578921 3/18/08 AP WILL BE A ROOF DRAIN INSPECTION FOR AREAS "C" AND "D". P359 13 3/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001580653 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 / 26 / 08 TI C*PLUMB OVERHEAD TIME: VENT VRU 001582931 ~L'Lfj/1~ WILL BE A CEILING WASTE AND VENT AND A ROOF OOF DRAIN INSPECTION IN AREA "A". COMMENTS AND NOTES PREPARED 3/27/08, 16:05:38 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 3/28/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER FAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M457 05 3 8/08 TI C*MECH DUCT TIME: 17:00 VRU 001584739 -WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING./- ` PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS~L 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 00143 7 - 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 0800 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 1700 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 1700 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BE C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. PREPARED 3/27/08, 16:05:38 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 3/28/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER BAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS *ROOF DRAIN MENS 40 BED AREA AND MECHANICAL ROOM. ROOF TEST WATER FILLED AND BOTTOM SIDE. *INDIVUDUAL SINKS VENTING AREA "D" P359 09 3/12/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001575729 3/11/08 CA MISC 03 3/14/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001577154 3/14/08 AP WILL BE FOR THE WASTE AND VENT DRAINS IN AREA C. P359 11 3/14/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001577147 3/14/08 AP P359 12 3/18/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001578921 3/18/08 AP WILL BE A ROOF DRAIN INSPECTION FOR AREAS "C" AND "D". P359 13 3/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001580653 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26108 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/~0~8i C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 'Alt &kE WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" COMMENTS AND NOTES PREPARED 3/28/08, 11:38:11 INSPECTION TICKET PAGE I Harnett County INSPECTOR: IVR DATE 3/28/08 - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 ,/2U/08 T,//~II~~ C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 M457 05 3/28/08 ~S~r C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D COMMENTS AND NOTES PREPARED 3/31/08, 14:34:10 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 4/01/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY CF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 ,4//20( TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 41/b08 WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/0 /08 7/I C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 WILL BE A OVERHEAD WATER PIPING. COMMENTS AND NOTES c. ~ PREPARED 4/01/08, 16:24:04 INSPECTION TICKET PAGE 1 Harnett County - INSPECTOR: IVR DATE 4/02/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDC/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection N,457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayrcom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WCULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 TI C*MECH CHIL ER PIPING TIME: 17:00 VRU 001587146 y aY I ~C C*MEC T MSUCT TIME: M.457 06 4 2/08 T J 1y#: (9587138 l ^J COMMENTS AN✓DGNOTES CJ PREPARED 4/08/08, 15:08:39 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 4/09/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRNCTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNEk'4 JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 T C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 ROOF DRAINS AREA "A" P359 17 4/ /08 T C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 OVERHEAD WATER IN AREAS "B" AND "D" - COMMENTS AND NOTES - I Laur naR i ckherSor - 1 7046220499 04/02/06 10440am P. 001 j i Q ry - / I/oZ t a MRENE RICKHER Br EORRELL, P C WmWtlry 9butluFl EnplnaerF I Post4e Fax Note 7671 mole Z 1vag"► 2 To 164 poY±RI,C.-Art- April 2, 2008 C e t. Co. phDn o Phone N Mr. Jim Palmieri, AIA Pox n Fax k••~: i.r Moseley Architects 11430 Norlh Conlnumity House Road Suite 225 `:'c- I Charlotte, NC 28277 111* RE: Harnett County Law Enforcement Center Lilengton, NC ! Dear Jim: We have received the review letter written by Mr. Stephen Fleming with Fleming & Aiiociates, P.A. dated March 18, 2008. We have the following comments regarding his analysis. j Mr: Fleming notes that his office used the Allowable Streas Design (ASD) method to review oui desigti. I Our design was completed using the Load and Resistance Factor Design (LRFD) method as allowed in Section 2205.1 in the North Carolina State Building Code (NCSBC). LRFD allows more ecoiwii biral 1 members than allowed by ASD. Therefore, inspecting beams designed by LRFD will not be viiid noting le ~ ASD inothod. I . We are in agreement with the loading applied to the beams used by Mr. Fleming Milt the exception of applying the live load reduction permitted by the code. Live load is permitted to be reduced based on the area the member supports. Section. 1607.5 of the NCSBC requires that a "live load" of 20 psf for partitions be included in office buildings where the design live load is less than 80 psf. Our design live load is 50 psf as required in Table 1607.1 phis the required 20 paf for a total live load of 70 psf which is reducible per Section 1607.9 of the NCSBC. Mr. Fleming reduced the 50 psf live load only. Mr. Fleming's analysis thus I has both higher total load and utilizes the ASD design method. We have reviewed and analyzed the structure using the actual concrete thickness provided by the contractor, reducible live load of 70 psf and using the LRFD approach. We hive found all of the beams, girders and columns to have sufficient strength for the loading noted above. We have also reviewed the connections in this portion of the building and found all but two that are acceptable for the loads: the W1605 at cohtmn B-10.9 and the W 16x26 at column C-11. The connection at B-10.9 will require welds in lieu of the bolts currently in place and the connection at C-1 I will require a .I stiffener plate be added to the seat connection currently in place. Sketches for this correction will sent to your office. j 3044600 10701 RM Oak BWI1 4 I Chaft* NC 20211 TN: 704.522a495 I FM 704.5=04W t E4MC tJlMa *rapc.Ml Lar ereRiakher-Sorrol 7046220499 04/02/09 10:40am P. 002 I i r Mr. Jim Palmieri, AIA April 2, 2008 Page 2 i It remains our opinion o»r design methods meet all code requirements and gives your client the design live { load capacity needed for his occupancy. ! Please call me with any questions or comments. pNNUpte/p N CARO a' Sincerely, QE I,AURENE, RICKHER & SORRELL P.C. nI ~ 546 1'rI Q ~ Mark S. Rickhea, PE IN Principal EVEN d• MNNIIItN~ cc: Duane Sirhal -Moseley Architcus (by email only) File i i I i l j i i i i f FLEMING & ASSOCIATES, P.A. Consulting Engineers 1004'Hay Street (910) 433-2825 Fayetteville, NC 28305 ' Fax: (910) 433-2604 !5 R Stephen Fleming, RE. Principal March 18, 2008 J. Ben Rogers; RE, Principal MAR 2 4?p~ Moseley Architects 11430 N Community House Road rrF~`7s Gibson Building, Suite 225 Charlotte, NC 28277 Attention: Jim Palmieri Re: Harnett Co. Detention Center Our Job No. 08-06 i Dear Mr. Palmieri:. As requested by you Fleming & Associates,.PA has completed a limited structural analysis to f determine in general if the existing.2" i floor composite steel-concrete floor framing can safely support the required live loads. It is our understanding that the unshored steel beams in question deflected downward during. the pouring of the floor slabs resulting in thicker slabs and greater dead loads. This apparently created concern regarding the adequacy of the beams to support the required floor live loads. Eight, members. were. selected for analysis based on member size, - tributary area, and span length. Allowable Stress Design was used. for our analysis. The following material strengths were provided by you for our analysis: I Light Weight Concrete Strength fc = 5290 psi (117 pct) Steel Strength Fy 51 ksi The revised live loads-and corresponding dead loads used in our analysis are listed in the Moseley Field Clarification FC#kl l/Sl: dated February 26, 2008. Essentially the field clarification reduces the live load capacity. in most.areas from 100 psf to 70 psf to include wall partitions. For. our calculations live load reductions were not takea.for the 20 psf partition load: The listed dead load of 5 psf was used in our analysis ;but should be field verified All revised loads should be listed on die as-built drawings so that they become a part of the permanent record and are not i exceeded. The actual thickness of the in-place concrete slabs was provided by you_in eight locations. Some assumptions of slab:thickness were made by our office using data from similar bays where no data was available and also where the slab thickness varied along the length of the beam. Five. beams and three girders were analyzed. At two girders. and at two beams the combined bending stress in the steel exceeded the maximum of 0.9 Fy. The. stresses ranged. from. 15% to 35%,greater than 0.9 Fy. This requirement is to preclude permanent deformation at service loads Page l of 2 and does not represent the ultimate moment capacity of the members. It is our opinion however that the. percentage of overstress. is significant and should be reduced:. At two.of the above mentioned girders the bending stress for the steel in the transformed sections exceeded the maximum allowable stress of 0.66 Fyby 4% and 21%. At these locations.the girders fail both , the tequirement for serviceability and strength. In some locations where the ` live load requirement is highei"the thicker slabs actually increased the strength of the original. design.. In other. locations it ieduced the live load capacity. More accurate slab depth information at these overstressed members could. possibly reduce the percentage of overstress. Also, in a discussion . withMark Rickhei, the engineer-0f-record; he stated that their office used the LRFD design approach instead of the Allowable Stress approach that we used to analyze the members. Both approaches are accepted by the American. Institute of Steel Construction. They also interpreted the NCSBC to allow live load reductions on the'20-psf partition icads..The LRFD .approach and the. additional live load reduction would reduce the,amountof overstress and could eliminate it in some members. - We recommend that the engineer-of-record obtain the actual slab: thickness. data and re-analyze the adequacy 'of the floor framing as our analysis was general m nature and did not include all floor members or connection design. We can provide specific, information at your request regarding the beams that we analyzed as overstressed. We also recommend that the 'engineer-of- record recalculate the.bearri shears to include the additional concrete weight and provide this data. to the connection design engineer in order to verify that the connections can carry . the additional concrete weight: The connection of the W 18x65 to the HSS column on cohunn line 11 has only. four bolts: - This does not appear adequate. Any. instructions for strengthening should be provided by the engineer-of-record.. It should be noted that Fleming & Associates, PA used information contained in the`contract documents and the steel shop drawings. for analysis. We did not visit#he site or field verify the . accuracy of these documents related to actual field conditions. i If we can be of further assistance please let me know. Sincerely,. Fleming & Associates, PA JN C O8 SEAL 9 Stephen Fleming, P.E.. t1278 Fk F1Ea ova row, Page 2 of 2 PREPARED 4/08/08, 15:08:39 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/09/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTR/1.TOi.*: BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 1 1-0650 - - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BE C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587138 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate m457 07 4/09/08 TI C*MECH DUCT TIME: 17:00 VRU 001589878 Lt- q -OW 4(g( WILL DE IN CHASE "C" 138 AND CHASE "F" 139. PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT' RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME- 17.00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b CONTINUED ONTO NEXT PAGE PREPARED 4/09/08, 15:32:50 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/10/08 ADDRE'SS : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". N.457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech.room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:.00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ck to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587138 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 08 4/10/08 T,j,r„ C*MECH DUCT TIME: 17:00 VRU 001591577 WILL BE A MECHANICAL DUCT INSPECTION FOR "F-138" PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - P357 01 6/20/07 BS C*PLUMS UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 - CONTINUED ONTO NEXT PAGE PREPARED 4/09/08, 15:32:50 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 4/10/08 ADDR.ESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/096/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/I/10/08_ ~7/~(~J~ C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 -lb-LnI-( Jfl' 3s WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". COMMENTS AND NOTES FLEMING & ASSOCIATES, P.A. Consulting Engineers 1004 Hay Street (910) 4332825 Fayetteville, NC 28305 ' Fax: (910) 4332604 D 2 Stephen Fleming, P.E. Principal March 18, 2008 (h, Li Q J~ J. Ben Rogers, EE. Principal U ~ MAR 2 9200 u ~ . Moseley Architects 8 11430 N Community House Road ~cHent a A~UPit rs Gibson Building, Suite 225 ~`v n'4 Charlotte, NC 28277 Attention: Jim Palmieri i Re: Hamett Co. Detention Center Our Job No. 08-05 Dear Mr. Palmieri: As requested by you Fleming & Associates, PA has completed a limited structural analysis. to determine in general if the existing.2"d floor composite steel-concrete floor framing can safely support the required live loads. It is our understanding that the unshored steel beams in question deflected downward during the pouring of the floor slabs resulting in thicker slabs and greater dead loads. This apparently created concern regarding the adequacy of the beams to support the required floor live loads. Eight members. were. selected for analysis based on member size, . tributary area, and span length. Allowable Stress Design was used for our analysis. , The following material strengths were provided by you for our analysis: i Light Weight Concrete Strength fc = 9290 psi (117 pcf) Steel StrengthFy 51 ksi i The revised live loads and corresponding dead loads used in our analysis are listed in the Moseley Field Clarification FC#11IS1 dated February 26, 2008. Essentially the field clarification reduces the live !oad.capacity inmost. areas from 100 psf to 70 psf to include wall partitions. For our calculations live load reductions were not taken.for the 20 psf partition load. The listed dead load of 5 psf was used in our analysis but should be field verified. All revised loads should be listed on the as-built drawings so that they become a part of the permanent record and are not exceeded. The actual thickness of the in-place concrete slabs was provided by you,in eight . I locations. Some assumptions of slab: thickness were made by our office using data from similar bays where no data was available and also where the slab thickness varied along the length of the i beam. Five. beams and three girders were analyzed. At two girders and at two beams the combined . bending stress in the steel exceeded the maximum of 0.9 Fy. The stresses ranged from 15% to 35%,greater than 0.9 Fy. This requirement is to preclude permanent deformation at service loads Page I of 2 . and does not represent the ultimate moment capacity of the members. It is our opinion however that the, percentage of overstress. is significant and should be reduced. At two of the above mentioned girders the bending stress for the steel in the transformed sections exceeded the maximum allowable stress of 0.66 Fyby 4% and 21%. At these locations the girders fail both the requirement for serviceability and strength. In some locations where the live load requirement is higher the thicker slabs actually increased the strength of the original design. In other, locations it reduced the live load capacity. More accurate slab depth information at these overstressed members could possibly reduce the.percentage of overstress. Also, in a discussion with.. Mark Rickhei, the engineer-of-record, he. stated that their office used the LRFD design approach instead of the Allowable Stress approach that we used to.analyze the members. Both approaches are accepted by the American Institute of Steel Construction. They also interpreted . the I}TCSBC to allow live load reductions on the 20 psf partition icads, The LRFD approach, and the, additional live load reduction would reduce the.amount of overstress and could eliminate it in some members. We recommend-that the engineer-of-record obtain the actual slab: thickness data and re-analyze the adequacyof the. floor framing as our analysis was general in nature and did not include all floor members or connection design. We can provide specific. information at your request regarding the beams that we analyzed as overstressed. We also recommend that the engineer-of- record recalculate the beam shears to include the additional concrete weight and provide this data to the connection design engineer in order to verify that the connections can carry the additional concrete weight: The connection of the W 18x65 to the HSS column on column line I 1 has only four bolts. This does not appear adequate... Any, instructions for strengthening should , be provided by the engineer-of-record. It should be noted that Fleming & Associates, PA used information contained in the,contract documents and the steel shop drawings:for analysis.. We did not visit4he site or field verify the accuracy of these documents related to actual field conditions; i If we can be of further assistanceplease let me know. Sincerely, Fleming & Associates, PA CI ti9 SEAL Stephen Fleming, P.E. 1278, •a FpQ P ~~Y ~ pyFN. F~~~ar . Page 2 of 2 i \I PREPARED 4/15/08, 9:23:09 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 4/15/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 TC*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 COMMENTS AND NOTES PREPARED. 4/18/08, 805:37 INSPECTION TICKET PAGE 3 "Harnett County INSPECTOR: IVR DATE 4/17/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT_ COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/C8 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 J Lf•I ' AO&AREAS C & A COMMENTS AND NOTES PREPARED 4/21/08, 15:25:54 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 4/22/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/2.0/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BE C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BE C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". ?353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4~~//{{{22/08 T~I~,~~ C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 ffYIC] 1 WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. COMMENTS AND NOTES PREPARED 4/22/08, 16:24:31 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 4/23/08 - - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE. 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : JAIL SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or i tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587138 4/02/08 DA Area "Cl- Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 08 4/10/08 BS C*MECH DUCT TIME: 17:00 VRU 001591577 4/10/08 AP WILL BE A MECHANICAL DUCT INSPECTION FOR "F-138" M457 09 4/23/0 T C*MECH DUCT TIME: 17:00 VRU 001597947 Q ~hydronic pipe for area a1& duct seal for area a as well as 2nd phase of area b ) J - - COMMENTS AND NOTES - - _WORENE K RICKHER. P .C. Cansulting Strudraal E gingers February 7, 2008 Mr. Dan Mace, AIA Moseley Architects 11430 North Community House Road Suite 225 Charlotte, NC 28277 RE: Harnett County Law Enforcement Center Lillington, NC Dear Dan: Last week while the contractor was pouring the concrete stab on metal deck he called us stating that they were experiencing some steel beam deflection. Immediately upon receiving this call we reviewed our design and analysis of the building] We found that camber to compensate for the dead load deflection (i.e. wet concrete weight) of the beams was not shown on the structural drawings. The beams were fabricated and erected flat. The as-constructed framing exhibits the deflection for which these beams could have been cambered. While this has led to the beams deflecting, the floor (i.e. concrete slab) has been finished to the required flatness and levelness and all beams, columns and connections have the capacity required by the North Carolina State Building Code. The stmctural integrity of the building has not been compromised by this issue. Please call me with any questions or comments. Sincerely. CAR~ ee ya LAAU/R~ ENE &~RICKHER, P.C. `Td°~+aq E °°°lQ tf 9 ( C/~ L Mark S. Rickher, PIR 1546 Principal ~e°asjEVEN ~~o+°++ eoe9eavecvvva1'° cc: Chris Moore - Moseley Architects (by email only) Duane Sirhal - Moseley Architects (by email only) File sulle 800 1 8701 Red Oak ft~d / Ckaeona HC 19117 TO: 104.M.N98 ! Fax: 704.522,0499 1 6Mal: chaMBe®kpe.nel ' i i LAURENE RICKHER & SORRELL RM Co Nft ftxkv l EKw i CONSTRUCTION MEMORANDUM: CM-006 LRSPC Project 05850 ! i Date: 02-28-08 Transmitted By. Email only j i To: DuaneSirhal,AIA- MoseleyArchitects Cc: Tom Bordeaux-Bordeaux Construction Co. From: Mark S. Rickher, PE RE: Harnett County Detention Center i I During my visit on February 27, 20081 noted a couple of connections that I wanted to review. I have reviewed those connections today and the foilowing connections do not provide the required capacity that is listed on our structural drawings. I They are as follows: Piece Mark 27B6 (W 12x14 along Line C between Lines 12 and 14) requires a 40 kip reaction at Column C-12. The connection as shown on the shop drawings does not provide this reaction. The connection will have to be modified to provide this reaction. i Piece Mark 11 B5 (W 16x26 along Line 11 between Lines C and D) requires a 44 kip reacton at Column C-11. The connection as shown on the shop drawings does not provide this reaction. The connection will have to be modified to provide this reaction. Piece Mark 8B1 (W 18x65 along Line 11 between Lines F and the CMU wall) requires a 43 kip reaction at Column F-11. The connection as shown on the shop drawings does not provide this reaction. The connection will have to be modified to provide this reaction. Please call with any questions. i i End of CM-006 i I i. II I, I I CM,I9tN, NC 25211 9Wm 500 ! 8704 ReE BON" I 791: 'f01b72.0/95 I Fart 7W 00 F.lAall: tl,vldte®YywnM r I LAURERF, RICKNER & SORRELL, P.C. Ca My SVeoWnl Enpl e CONSTRUCTION MEMORANDUM: CM-007 LR8PC Project 05aso I Date: 04-03-08 Transmitted By: Email only i To: Duane Sirhal, AIA - Moseley Architects Cc: Tom Bordeaux - Bordeaux Construction Co. From: Theresa F. Giles, PE RE: Harnett County Detention Center i The letter sent from our office by Mark Rickher dated April 2, 2008 mentioned two connections that need to be modified for the current loads. They on the second floor of Area A in the following locations: Connection of W1605 to column at grids B.1 & 10.9. Weld the existing single connection plate to the web of the beam with 'A" fillet. Remove bolts after welding is complete. Refer to attached sketch CM007-SKI. Connection of W1 6x26 to column at grids C & 11. Add 3/8° stiffener plate to existing angle seat at bottom of beam. Refer to attached sketch CM007-SK2. i During our connection review process It was determined that the connection of the W1 4x22 to the column at grids B.1 & 9 was not adequately designed. The connection provided on the shop drawings has a 12 kip capacity and the reaction indicated on the drawings is 14 kips. The steel fabricator should provide a repair detail to be reviewed by LRSPC. l Please let us know if futher clarification is required on any of the above items. End of CM-007 i i i I k Baukv allbVa, HC2B1T -MMOS IO Oa SW M I Tel: 70VSA / Fm .c To/,5mA FM / I Chw e, NC bryc~wl i LAURENE & RICKNER, RC. Gmsuldng SUv=ml Enjne DATE PROJECT SHEET NO. OF ENOR SUBJECT JOB NO. 6 5?A_ 1 q I 1sT- llN Al IG , Q.~iMQ+~~ _ ~pii7S A-FTE(C WELDiN~ I j ' ! i k IS Cpm (JL~TR ~K~SS I I ~ ~w.sr. w~(~f4s CoUUAn1 N ! f„ 1 y 3° v~~vw~ TZ 4- POT ~l ELD Fl X FofL wi Ce 66NN, CO 6.1- IM i i. i I i J i i I i GMoa-J- Sic2 i - i I i 4-71 f f- t- 1 j I ~ -t- .I (L V i f ! i s• f - iF-4 i I 450320 OSELEYARCHITECTS A P R O F S S$10 N A L C O R P O R A T I O N 11430 North Connnunr Houo Rwd.Gtuur Bu1IdrQ - Suite 226 ChWeffe,North Coroatw 26277. (704) 540.9756 • FAX (704)(540W54 I FIELD CLARIFICATION Project: Hamett County Detention Center FC Number: 013 To: Bordeaux Construction Company, Inc. Date: 17-Apr-08 Attention: Tom Bordeaux Project No.: 450320 Specification No.: N/A Drawing No.: S2.2A Subject: Clarifications to Structural Steel Connections You are hereby directed to promptly execute this Field Clarification, which interprets the Contract Documents or orders minor changes in the Work without change in the Contract Slim or Contract Time. If you consider that a change in Contract Sum or Contract Time is required, please submit your itemized claim to the Architect immediately and before proceeding with this Work. If your claim is found to be justified and in proper order, this Field Clarification will be incorporated into a Change Order. Description: Clarifications to structural steel connections between columns and beams per attached Laurene, Rickher & Sorrell CM-006 dated 2/28/08; and Gira Steel NFC#2 with SK2, NFC#3 with SK3, and NFC#4 with SK4 all dated 2/29/08. Encl.: As Stated Cc w/encl.: Tony Wilder, Harnett County j Mark Rickher, LRS Theresa Giles, LRS i By: Duane A. Sirhal, AIA Construction Administrator ;t i File Cade: Q FC - l V i i i 450320 M®SELEYARCHITECTS A PROF69$10NAt CORPORATION 11630 Narlh CorrmurNr Holm Rwd. GRSan B&dtdng- Silo 716 Garotte, North Camino 28277 a M) U"766 • FAX (700164M760 FIELD CLARIFICATION Project: Harnett County Detention Center FC Number: 014 To: Bordeaux Construction Company, Inc. Date: 17-Apr-08 Attention: Tom Bordeaux Project No.: 450320 Specification No.: N/A Drawing No.: S2.2A Subject: Clarifications to Structural Steel Connections You are hereby directed to promptly execute this Field Clarification, which interprets the Contract Documents or orders minor changes in the Work without change in the Contract Sum or Contract Time. If you consider that a change in Contract Sum or Contract Time is required, please submit your itemized claim to the Architect immediately and before proceeding with this Work. If your claim is found to be justified and in proper order, this Field Clarification will be incorporated into a Change Order. Description: Clarifications to structural steel connections between columns and beams per attached Lauren, Rickher & Sorrell CM-007 with SKI and SK2 all dated 4/3/08. Encl.: As Stated Cc w/encl.: Tony Wilder, Harnett County Mark Rickher, LRS Theresa Giles, LRS A4L~) By: Duane A. Sirhal, AIA Construction Administrator Me Cade: 0 fC - I (OMMEt1-t5 f5~ C1kER~A CaVt65 t,AV~EtJEdr R1 LkbFE~ 3.S C8 Form 18.1 Gin Immm S T E E L t'AMUCATORS OFTIRUC URALM91®CRINiBO[/S 9M AawriryAftwim BuAnMEhavpd" 841 Vfti mn Sheet • W. COunbia, SC 29169 NOTICE OF FIELD CORRECTION TFJaphm ' (803) 796-9495 • Fu: (803) 796.9496 NFC NUMBER :REV: JOB NUMBER SEQUENCE: TE 2 07=106 A 2129/2008 ERECTION DRAWING NUMBER DETAIL DRAWING NUMBER - j Et 27,38 LOCATION OF CORRECTION MEMBER TO CORRECT: LOCATION: - CONNECTING MEMBER: 2786 Column Lines 121C 3802 . DESCRIPTION OF PROBLEM: I i i Feld review by Engineer of Record found that the South side connection of column 38C2 to beam 2786 was not detailed fore 40 kip reaction. NOTIFICATION PARTY NOTIFIED: COMPANY: Milton Boyette Bordeaux Construction Company - PHONE;' TW F MAIL,• DATE: SUBMITTED BY: COMPANY: X 2129/2006 Milton Boyette Bordeaux CORRECTIVE PROCEDURE: Feld weld shear tab to web of beam 3 sides (total of 141/2') with a 3/18" fillet weld 3 sides. Add new to underside of beam, with a 1/4" fillet weld. Fleld well new angle to column with a flare j~X )e 1'Z weld each aide of angle.. Remove bolts from shear tab connection. FIELD WORK'DRAWING NUMBER DATE: APPROVED BY: SK2 2/2912008 DISTRIBUTION ERECTOR CUSTORMER: ENGINEER - i Bordeaux COnstructlon Co. v- 1 - OTHERS: NFCO ISIGNm: DATE: = ORIGINATOR DEPARTMENT OR COMPANY: 2I2gI0b twcac ` E RIO R S O U R C E: emlling.(Lafance) CHARGES FOR EXTRA WORK SUBMITTED WTTHOUTAN NFC NUMBER WILL NOT BE ACCEPTED ! PAGE OF i S T E E L 1"WANIS gem no== M mzffcrB41, am 1M1'9]ltl M sm • vas a~ W. + mft"v 8!1 Ut%ms St- • West Columbia, SC 88189 Telephone: (899)798-8496 • Fay (803) 798-8499 Date: Lai Lob . YUL fob No. 0 -106 Shetoh No. 4 i i 4-11 Imp tip 4iak5 , ! I t F j_ i I, i I_ 1 ' r i i , I 1 I I I I S T E E L ra = m69 An s OF smom" um N MUNEW JIM - Yi+uM1Y • Ioamfl B/nalw EnGrprW . 04! "Same St west Columbia, Oc i9189 . 7aleoho= (803) 796-6496 • Fax: (803) 798-0490 Job No. cam- ate Sketch N& 2~5 Date: Fill r a I 1_ ~ I __i -I 1 T- 17 I 7 --I 1 T-1 F PREPARED 4/03/08, 8:59:32 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 4/03/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT - CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4 03,/00 TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 5 WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/ /08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". COMMENTS AND NOTES ! Form 18.1 5 T E E L - FAMCATM OPMULT[ALALANDMf3C IUANBOUS SMM - 14&kw yBmwpri -Wovaan 9w au &vs prt¢ - - - 841 WiIliama Shcd.• W Columbia, SC29169 . NOTICE OF FIELD CORRECTION 7tlephooe: ")796-9495-F=(803)796-9496 NFC NUMBER: REV: JOB NUMBER: SEQUENCE: TE: 3 07-106 A 2/20008 ERECTION DRAWING NUMBER: DETAIL DRAWING NUMBER Et 11, 41 LOCATION OF CORRECTION . . . MEMSERTO CORRECT: LOCATION: CONNECTING MEMBER: ` i 11B5 Column Lines 11/C 41C1 DESCRIPTION OF PROBLEM:. - Field review by Engineer of Record found that the West side connection of column 41C1 to beam 1185 eras not detailed for a 44 kip reaction. NOTIFICATION PARTYNO FIED: COMPANY: Milton Boyette Bordeaux Construction Company' PHONE: FAX: MAIL DATE SUBMITTED BY: COMPANY: X 2128/2008 Milton.Boyette Bordeaux CORRECTIVE PROCEDURE: Field weld shear tab to web of beam 3 sides (total of 1 a') with a 3/16" fillet weld 3 sides. Add new ag@Mpto underside Of beam with a 114" fillet weld. Field weld new angle to column with a flare q ;/g y weld each side of angle. Remove bolts from shear tab connection. FIELD WORK DRAWING NUMBER: DATE APPROVED BY: SK3 2128/2008 DISTRIBUTION ERECTOR CUSTORMER: ENGINEER: Bordeaux Construction Co. OTHERS: . NFCO GINATOR SIGNED: DATE: ORIGINATOR DEPARTMENT OR COMPANY[ - - ! *dk1O& QA/4C ERROR SOURCE: tailing ranee) CHARGES FOR EXTRA WORK SUBMITTED WITHOUT AN NFC NUMBER WILL NOT BE ACCEPTED - I PAGE OF i i S T E E L rrrao.rty saery.w • vaemn amw.. 861 Man SL • lest Columbia, SC 29189 Tobpkm: (899) 796-OM • Fm (e89) 79e-9698 • ~ I rob No. 01' IOLo - mm ah N. en" Date: I i I I ~ I I _I~-a-- , i I I ~ E t a I z_„- i l i' I I I I ! 1 L__t_1_J.._..:__i_i_._._.t_... L__:__t-.l_..._!.. i I I i Form 18.1 on wmr 'M 5 T E E L FAWCAT RS0FMXC1VMANDMNCSL1NfiO aMIL . - Mlmorhyt.Mery+Lre"Bbmm~Budrw~Erutrynre . i ' 841 WMhw Street" W. Columbia. SC29169 NOTICE OF " F I E L D C O R R E C T I O N Tdgbmm (803) 796-9495"F= (803 79B 9496 NFC NUMBER: 'REV: 108 NUMBER: SEQUENCE: DATE: - 4 07-108 A 2129/2008 ERECTION DRAWING NUMBER DETAIL DRAWING NUMBER: Et 8. A3 LOCATION OF CORRECTION MEMBER TO CORRECT: LOCATION: CONNECTING MEMBER " i i 8131 Column Lines 11/F 43C1 DESCRIPTION OF PROBLEM: i Field review by Engineer of Renard found that the West side connection of column 43C1 "to beam 881 was not detailed for a 43 kip reaction. NOTIFICATION PARTY NOTIFIED: - COMPANY: Milton Boyette Bordeaux Construction Company - j . PHONE: J-- F MAIL• DATE: SUBMITTED BY: COMPANY: X 2129&08 Milton Boyette Bordeaux CORRECTIVE PROCEDURE: Reid weld shear tab to web of beam 3 side's (total of I w j with a 3116" fillet weld 3 sides. Add new underside of beam with a 114" fillet weld. Field weld new angle to column with a flare 3 weld eadl side of angle. Remove bolts from shear tab cbnneetion. Ll 4 FIELDWORK DRAWING NUMBER DATE APPROVED BY: SK4 2129/2008 DISTRIB TION ERECTOR:. _ CUSTORMER _ ENGINEER . Bordeaux Construction Co. " OTHERS:. i' NFCO`INATORSIGNED: DATE: T ORIOIWITOR DEPARTMENT OR COMPANY: uuulr~ ►~Y yZgl ~a QA/QC E R O R S O U R C E: falling (t.afancel CHARGES FOR EXTRA WORK SUBMITTED WITHOUT AN NFC NUMBER WILL NOT BE ACCEPTED PAGE OF Y Page 1 of 2 Lynwood Mcdonald From: Palmieri, Jim 5palmieri@moseleyarchitecls.wm) Sent: Thursday, April 17, 2008 4:00 PM To: Tony Wilder; Mace, Dan; Moore, Chds; Sirhal, Duane Cc: Neil Emory; Lynwood Mcdonald; Brad Sutton; Tom Bordeaux; mridaher@lrpc.net Subject: RE: Steel Deflection--Hamelt Detention Center Tony, In response to your request, attached are Field Clarifications #13 and #14. FC #13 addresses connections that were not designed/detailed by Gira (structural fabricator/detailer) per the requirements of the construction documents. FC #14 revises two connections do to the additional concrete load. In addition we have attached the original letter from Mark Rickher (Lauren, Rickher & Sorrell, P.C.) and the follow-up letter responding to the analysis performed by Fleming & Associates. Please let us know if you require any additional information or documentation. Thank you. Jim Palmieri, Ala, CSI Senior Associate MOSELEY ARCHITECTS Architecture. Engineering. Interiors. Planning Suite 225 11430 North Community House Road Charlotte, NC 28277 704.540.3755 FAX 704.540.3754 CELL 704.995.4020 W W IN.MOSE LEYARCH ITECTS.COM From: Tony Wilder [mailto:twilder@harnett.org] Sent: Thursday, April 17, 2008 9:58 AM To: Palmieri, Jim; Mace, Dan; Moore, Chris; Slrhal, Duane Cc: Neil Emory; Lynwood Mcdonald; Brad Sutton; Tom Bordeaux Subject: RE: Steel Deflection--Harnett Detention Center 1 know Jim has been out, Any word from the structural engineer conceming the below? I know Bordeaux will be ready to hang sheetrock soon....... Wm. A. (Tony) Wilder, Asst. County Manager County of Harnett P. O. Box 759 l.illington,NC 27546 910-893-7555 910-814-2662 (fax) Harnett b;y C0 u NTy strong roots • new growth -----Original Message----- From: Tony Wilder Sent: Tuesday, April 08, 2008 4:25 PM To: 'Palmieri, Jim' Cc: Dan Mace (dmace@moseleyarchitects.com); Chris Moore (cmoore@moseleyarchitects.com); Simal, Duane; Neil Emory; Lynwood Mcdonald; Brad Sutton Subject: Steel Deflection--Harnett Detention Center 4/17/2008 Page 2 of 2 Jim, We have read the letters from Steve Fleming and Mark Rickher concerning the deflection of the steel beams at the Harnett Detention Center. Based on the different approaches we request the following documents: 1-Our Inspections Department would like a full report on any changes made or will be made from the specifications because of the deflection. 2-A letter of record for our files that so states that Lauren, Rickher & Sorrell, P.C. warrants that the building meets all building codes on structural design and that they take full responsibility that the facility will be structurally sound based on its design and construction according to design. Call me should you have questions. We are ready to move on so that the contractor can install sheetrock when ready. tw Wm. A. (Cony) Wilder, Asst. County Manager County of Harnett P. O. Box 759 Ullington,NC 27546 910-893-7555 910-814-2662 (fax) Harnett CD uNrr strong roots • new growth 4/17/2008 i 450320 ®SELEYARCHITECTS A P R OF E R $ 1 ON AL CC R P O R AT I ON 11430 Norm CunvnunaV Home Road. GNson BuIdN - Su le 226 CharW e.Naft Com&w 28277• (104)50,17,56- FAX (704) 640.3754 i FIELD CLARIFICATION Project: Harnett County Detention Center FC Number: 013 To: Bordeaux Construction Company, htc. Date: 17-Apr-08 Attention: Tom Bordeaux Project No.: 450320 Specification No.: N/A Drawing No.: S2.2A Subject: Clarifications to Structural Steel Connections You are hereby directed to promptly execute this Field Clarification, which interprets the Contract Documents or orders minor changes in the Work without change in the Contract Sum or Contract Time. If you consider that a change in Contract Sum or Contract Time is required, please submit your itemized claim to the Architect immediately and before proceeding with this Work. If your claim is found to be justified and in proper order, this Field Clarification will be incorporated into a Change Order. Description: Clarifications to structural steel connections between columns and beams per attached Lauren, Rickher & Sorrell CM-006 dated 2/28/08; and Gira Steel NFC#2 with SK2, NFC#3 with SK3, and NFC#4 with SK4 all dated 2/29/08. Encl.: As Stated Cc w/encl.: Tony Wilder, Harnett County Mark Rickher, LRS Theresa Giles, LRS i By: Duane A. Sirhal, AIA Construction Administrator I file Code., 0 k / i i i LAURENE, RtCKHER 8r SORRELL, P.C. Cm Wq em *W r+girces - I CONSTRUCTION MEMORANDUM: CM-006 tR$PC Project: 058M I Date: 02-28-08 Transmitted By: Email only i To: Duane Sirhal, AIA - Moseley Architects Cc: Tom Bordeaux-Bordeaux Construction Co. From: Mark S. Rickher, PE RE: Harnett County Detention Center I During my visit on February 27,2008 1 noted a couple of connections that I wanted to review. I have reviewed those connections today and the following connections do not provide the required capacity that is listed on our structural drawings. They are as follows: Piece Mark 2786 (W12x14 along LineC between Lines 12 and 14) requires a 40 kip: reaction at Column C-12. The connection as shown on the shop drawings does not provide this reaction. The connection will have to be modified to provide this reaction. Piece Mark 11B5 (W1 6x26 along Line 11 between Lines C and. 0) requires a 44 kip reacton at Column 'C-11. The connection as shown on the shop drawings does not provide this reaction. The connection will have to be modified to provide this reaction. Place Mark 8B1' (W 18x65 along tine 11 between Lines F and the CMU wall) requires a 43 kip reaction at Column F-11. The connection as shown on the shop drawings does not provide this reaction. The connection will have to be modified to provide this reaction. Please call with any questions. I End of CM-006 I i i 'I I i SWb600/ FR,eoakeWN I E2CMd. m.na& dGU TM: T01.W21NY5 1 F. 7U6.473b®I1.pc„w I i (,erY~ r►TETJTS ~i~ 'l'k~~R.C-5 A GIBS I.AUP ~N~~ W Gk bFt✓~2 3•. C Fom1 18.1 a ,I MIA 4 T E B L FABRICATORS OF MRUCnMAL AM MLSCMIANKXX STEM Mbwdfy Ewgrlsr• W6 BuAnwEM,pk. 941098i~ Sheaf • W. CoLwtia, SC 79169 NOTICE O F FIELD C O R RE C T 10 N°ph=' (8021) 796-9495 - Fa; (sm) 796-9496 NFC NUMBER .REV:. JOB NU BER SEQUENCE TE 2 07 ~oB A WkObB ERECTION DRAWING NUMBER DETAIL DRAWING NUMBER j; E1 27,38 LOCATION OF CORRECTION MEMBER TO CORRECT: LOCATION: CONNECTING MEMBER I 2768 Column Lines 12/C 38C2 . DESCRIPTION OF PROBLEM: I Field review by Engineer of Record found that the South side connection of column 3802 to beam 27BG was not detailed for a 40 kip reaction. i I i NOTIFICATION PARTY NOTIFIED: COMPANY: I Milton Boyette Bordeaux Construction Company PHONE:' F MAIL DATE: SUBMITTED BY: COMPANY: X 229!2008 Milton Boyette Bordeaux CORRECTIVE PROCEDURE:' " Feld weld shear tab to web of beam 3 sides (total of 1412') with a 3/18" filet weld 3 sides. Add new to undersida of beam.wUh a 1/4" fillet weld. Field weld new angle to column with a flare +JL weld each side of angle.. Remove bolts from shear tab connection. FIELD WORKDRAWING NUMBER DATE: APPROVED BY: SK2 212912008 DISTRIBUTION ERECTOR CUSTORMER: ENGINEER Bordeaux Construction Co. OTHERS: - NFCO GINATOR SIGNED: DATE: ORIGWATOR DEPARTMENT OR COMPANY: j 2~2q,pg QA/QC ERROR 9 0 U R C E stalling (Lafance) CHARGES FOR EXTRA WORK SUBMITTED WITHOUT AN NFC NUMBER WILL NOT BE ACCEPTED _ PAGE OF J~ i Gira. S F E E L asesleamas M MZMM M a RIfL7'ORI AM MMMLA IoM 81M 841 inwama 8L • Teat Columbia, SC 79196 Telephone: (803).796-8498 - Paz: (803) 796-9498 I'll Ne. O?- 0 SkO h No. - Date: i lty- J! ;-i- - ( _ '~--i I I t i .t~._ -._a 7 7-- L ,-'-i- 4 fi j ; r I l I { Form 18.1 i S T H E L - - ! FABECATM OFSMUCNRA LAND NUSC&]ANBOU551}]9. - . M1wdryBQeryrire•FAmian Burineir HnMprirc 841 VMHi St • R_ Cabmbi4 SC 29169 NOTICE OF FIELD CORRECTION 'klephom: (863)796-9495- Fax: (SOS) 796,9496 NFC NUMBER REV. JOB NUMBER: SEQUENCE: DATE: 3 07-106 A 2/29/2008 ERECTION DRAWING NUMBER: DETAIL DRAWING NUMBER: El " 11,41 LOCATION OF CORRECTION MEMBER TO CORRECT: LOCATION: CONNECTING MEMBER: i 1185 Column tines 11JC 4101 DESCRIPTION OF PROBLEM:. - Field review by Engineer of Record found that the West side connection of column 41C1 to beam 1185 was not detailed for a 44 kip reaction. i i 7- NOTIFICATION PARTY NOTIFIED: COMPANY: Milton Boyette Bordeaux Construction Company PHONE: FAX: MAIL' DATE SUBMITTED BY: "COMPANY: X 2J28l2008 Mllton Boyette Bordeaux CORRECTIVE PROCEDURE: Field weld shear tab to web of beam 3 sides (total of 18") with a 3116" fillet weld 3 sides- Add new to underside Of beam with a 174" fillet weld. Field weld new angle to column with a flare weld each side of angle. Remove bolts from shear tab connection.. i FIELD WORK DRAWING NUMBER DATE APPROVED BY: SK3 2@8/2008 DISTRIBUTION ERECTOR CUSTORMER: ENGINEER i Bordeaux Construction Co. OTHERS: NFCO INATOR SIGNED: DATE: ORIGINATOR DEPARTMENT OR COMPANY: - i- . .9(06 0A/OC f ERROR SOURCE: teilln Afance) { CHARGES FOR EXTRA WORK SUBMITTED WRHOUTAN NFC NUMBER WILL NOT BE ACCEPTED - i PAGE OF V 1 i S T E E L FiBfOMBS AM WC= OF SFB9MMC W SOS ate, "I nu ma SL • lest Colmmma. 9C 29189 . Telephone: "(843) 799-9498 Fa7c (999) 798-9198 l06 No. 01-106 91oeMh No. Date: r- { I Y_ L , AIJI L-L-,-__a.._ j-~ -f - 7-1 4 I i I I Form 18.1 >o I 5 T E E L PARMCATORS OPSTRUCnIRAL AND MISCE LANS0 1 STIM - M1WftFAftryriw- W6 Busb jEnkryrist ' 841 R4• wu; Stmt • W. CNaIDhia, SC29169 NOT 1 C E 0 F FIELD CORRECTION 1a qh= (803) 796-9495"Fax: (Bai 7 96A496 NFC NUMBER REV: _ JOB NUM R SEQUENCE: DATE: A 2129!2008 4 ERECTION DRAWING NU BEEROT-106 DETAIL DRAWING NUMBER - E7 8.43 LOCATION OF CORRECTION MEMBER "TO CORRECT: LOCATION: CONNECTING MEMBER 881 Column Lines 111F 43C1 DESCRIPTION OF PROBLEM: I Field review by Engineer df Record found that the West side connection of column 43C1.to beam 8B1 was not detailed for a 43 kip reaction. i NOTIFICATION PARTY-NOTIFIED:COMPANY: Milton Boyette ' Bordeaux Construction Company PHONE: F MAIL: . DATE SUSMITTEDBY: COMPANY: X 2/29/2008 Milton Soyette Bordeaux CORRECTIVE PROCEDURE! Field weld shear tab to web of beam 3 sides (total of 18') with a 3116" flliet weld 3 sides. Add new underside of beam with a 1'/4" fillet weld. Field weld new angle to column with a flare L~ 3 weld each side of angle. Remove bolts from shear tab connection. FIELDWORK DRAWING NUMBER: GATE: • APPROVED BY: 3K4 2129/20DB DISTRIBUTION . E _ ERECTOR. _ CUSTORMEFt Bordeaux COn6RUCtlon Co. OTHERS:" - . OR SIGNED: DATE: ORIOINA70R DEPARTMENT OR COMPANY: NF O INAT 2l'L1lab QA/QC E R 0 R S O U R C.E: pelialfing (Lefancel j CHARGES FOR EXTRA WORK SUBMITTED WITHOUTAN MFG NUMBER WILL NOT BE ACCEPTED I PAGE OF J ~ Gwo S T E E L PIBW- = AM 9►BCM OF BMUMM4L 49e MUXM XM HM e . ram¢a B=f- aNNorp to 84t WDHame 8t • Heat CoWmble, 8C 29!89 Telephone: (809) 798-9498 • Fa= (909) 799-9498 - t lob No. 01- (OLp ffieteh No. r Date: i 1 ~ E ~ I I~ i 1 I _ ! l r- _ [ k 1 ) I i I r t i I , I ! 1 1 ! i__ I- f ' I I ~ 11 I l i i , i l l! I 1 I! j i ~I I I y 4 1 1 1 1 -I•--. I ~ I I---i j`.. I i f I I~ I 1 I ! i I i t ! I I J_ -i I. i I 450320 MOSELEYARCHITECTS A P R O F E S S I O N A L C O R P O R A T I O N 11480 Nadh Cortft Molex Road. GExan Ultling- Salo 226 Ctarloft North Comino 28277 • (700) 540 3766 • FAX (7006403754 FIELD CLARIFICATION Project: Harnett County Detention Center FC Number: 014 To: Bordeaux Construction Company, Inc. Date: 17-Apr-08 Attention: Tom Bordeaux Project No.: 450320 Specification No.: N/A Drawing No.: S2.2A Subject: Clarifications to Structural Steel Connections You are hereby directed to promptly execute this Field Clarification, which interprets the Contract Documents or orders minor changes in the Work without change in the Contract Sum or Commct'rime. If you consider that a change in Contract Sum or Contract Time is required, please submit your itemized claim to the Architect immediately and before proceeding with this Work If your claim is found to be justified and in proper order, this Field Clarification will be incorporated into a Change Order. Description: Clarifications to structural steel connections between columns and beams per attached Laurene, Rickher & Sorrell CM-007 with SKI and SK2 all dated 4/3/08. Encl.: As Stated Cc w/encl.: Tony Wilder, Harnett County Mark Rickher, LRS Theresa Giles, LRS *At i' By: Duane A. Sirhal, AIA Construction Administrator I i i File Code. © FC r I LAUREHEa RICKHER & SORRELL P.C. CmauWa rn"m i CONSTRUCTION MEMORANDUM: CM-007 LRSPC Project: 0.5850 ' Date: 04-03-08 Transmitted 8y: Email only i To: Duane Slrhal, ALA - Moseley Architects Cc: Tom Bordeaux - Bordeaux Construction Co. From: Theresa F. Giles, PE RE: Hamett County Detention Center I The Lettensent from our office by Mark Rickherdated-April 2; 2008'mehtlohed two connections _ thatneed to be modified for the current loads. They on the second floor of AreaA in the following locations:, Connection of W 16x45 to column at grids B.1 & 10.9. Weld the existing single connection plate to the web of the beam with'/." fillet. Remove bolts after welding is complete: Refer to attached sketch CM007-SKI _ Connection of W1 6x26 to column at grids C & 11. Add 318-bliffanerplate to existing angle seat at bottom of beam. Refer to attached sketch CM007-SK2. During our connection review process It was determined that the connection of the W 14x22 to'the column at grids' 8:1 &9,wawrrot adequatefTd&igried: The connection provided on the shop' drawings has a 12 kip capacity and the' reaction indicated on the drawings is 14 kips. The'steel fabricator should provide a repair detail to be reviewed by LRSPC. Please let us know tf futher clarification is required on any of the above items. i I I End of CM-007 i I i Sdk 5001 Pea Oak UWmrd l ChaaWa. NC=17 - Tm; 104.SM0465 I Fx T04,=0485I F MWI: WdWS®Inar:nal 1 j t LAURENE & RICKHER, P.C. Con%tdng Sb w ml Engineers DATE PROJECT HM11) Ir' T C PL SHEET NO. OF i ENGR ~Gl 8UBIECT JOB NO. ( SfSS~ j i i €1GSi: Gew a 1'~ t 26n~E Bp~'tS A-F-CF~2 wEtuiu~ I I i ~ tS Cpm AV~'Te RtST III A-( Zw"i FL ~~s L (OLINh r.) t o +I to t V f o t «.V: 3 Nr t ~L~ X FOfL LAJ Ce (bNNQt b Ge.l,v w1 N ~T >3.1- 1b.~i v J 1 I i i GMoa~- SkZ i t 1 ; I r'~'` -~}--~----I- i - 4 tt- 44 1, 1 j LAURENE & RICKHER P.C. Cv Imq swN.a Fs6ln. February 7, 2008 Mr. Dan Mace, AIA Moseley Architects 11430 North Community House Road Suite 225 Charlotte, NC 28277 RE: Harnett County Law Enforcement Center Lillington, NC Dear Dan: Last week while the contractor was pouring the concrete slab on metal deck he called us stating that they were experiencing some steel beam deflection. Immediately upon receiving this call we reviewed our design and analysis of the building. We'found that camber to compensate for the dead load deflection (i.e, wet concrete weight) of the beams was not shown on the structural drawings., The beans were fabricated and erected' flit. The as-constructed framing exhibits the deflection for which these beams could have been cambered. While-this has led to the beams deflecting, the floor (i.e. concrete slab) has been finished to the required flatness and levelness and all beams, columns and connections have the capacity required by the North Carolina State Building Code. The structural integrity of the building has not been compromised by this issue. Please call me with any questions or comments. Sincerely, 4ktee4aeaneeePPa ~e4~4RH CAR LAURENE & RICKHER, P.C. .`~r~~gR°e'F IQ 9 °^y Mark S. Rickher, PE -it 1546 Principal pd l~ YN\G` qa °~oy Jf V E N R c>~° FOPaDOPY6Pi4°M1y0 cc: Chris Moore - Moseley Architects (by email only) Duane Sirhal - Moseley Architects (by email only) File 8u6e 500 1 8701 Red Oak BNNvard I Ckedatm. NC 29277 Tel: 704A .%95 1 Fax: 704.522.0469 1 Edael: chalWeakpc.net LaurenaiRickherSor el 7046220499 04!02!08 10a4elam P. 001 , 1 LAURENE RICKHER & SORRELL P.C. C..111.9 ft.W lEnelaeers f i Post-iC Fax Note 7671 male 2 pag-0. To Fro p t<- April-2; 2008 0 $ "+AL cO' Rrone 8 Phwle e Mr. Jim Palmeri, AIA - Fax d Fer s Moseley Architects 11430 North Community House Road _r Suite 225 Charlotte, NC 28277 I RE: Harnett County Law Enforcement Center 1411ington, NC I Dear Jim - i We have received the review letter written by Mr. Stephen Fleming with Fleming & Associates, P.A. dated March 18, 2008. We have the following comments regarding his analysis. Mi.'Fleming notes that his office used the Allowable Stress Design (ASD) method to review our design. Our design was completed using the Load and Resistance Factor Design (LRFD) method as allowed in ' Section 2205.1 in the North Carolina State Building Code (NCSBC). LRFD allows more ecortemical members than allowed by ASD. Therefore, inspecting beams designed. by LRFD will not be valid using the ASD method. We are in agreement with the loading applied to the beams used by Mr. Fleming -with the exception of applying the live load reduction permitted by the code. Live load is permitted to be reduced based on the j area the member supports. Section 1607.5 of the NCSBC requires that a "live load" of 20 psf for partitions be included in office buildings where the design live load is less than 80 psf. Our design live load is 50 psf as required in Table 1607.1 phis the tequired 20 psf fora total live load of 70 psf which is reducible per Section 1607.9 of the NCSBC. Mr. Fleming reduced the 50 psf live load only. Mr. Fleming's analysis thus. .h$aboth higher total load and utilizes the ASD design method. We have reviewed and analyzed the structure using the actual concrete thickness provided by the ICI contractor, reducible live load of 70 paf and using the-LRFD approach. We have found all of the beams, girders and columns to have sufficient strength-for. the. loading noted above. - We have also reviewed the connections in this portion of the building and found all but two that are acceptable for the loads: the W 16x45 at column B-10.9 and the W 16x26 at column C-1 1: Th.e connection atB-10.9 will require welds .inben of the bolts currently in place and the connection at C-11 will require a stiffener plate be added to the seat connection currently in place, Sketches for this correction will sent to your office. j. I I Suits 500 w 8701 Pe Oak awls rd I CWcae, NC 29217 Tel: 7N 522.0485 r F=. 704.622A4all I E-Mail: G WeVh .Ml LaureneRi kherSor l 7046220999 04/02/08 10:40am P. 002 i 1 i I Mr. Jim Palmieri, AIA - 1 April 2, 2008 - Page 2 1 It remains our opinion our design methods meet all code requirements and gives your client the design live f load capacity needed for his occupancy. - Please call me with any questions or comments. tH~CARp~ Sincerely, LAURENE, RICIUMR & SORRELL, P.C. dj 546 Mark S. Rick-her, PE 9P,fs N6W Principal, 06II1#11160 - cc: Duane Sirhal-Moseley Architects (by email only) File i i I i i i . 4 i I f PREPARED 4/30/08, 14:05:02 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 5/01/08 ADDRESS . ----55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR .'BO]FiEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BE C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BE C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587138 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 08 4/10/08 BS C*MECH DUCT TIME: 17:00 VRU 001591577 4/10/08 AP WILL BE A MECHANICAL DUCT INSPECTION FOR "F-138" M457 09 4/23/08 BE C*MECH DUCT TIME: 17:00 VRU 001597947 4/23/08 AP hydronic pipe for area a & duct seal for area a as well as 2nd phase of area b M457 10 5/01/0 TI C*MECH DUCT TIME: 17:00 VRU 001601939 S- 1 -J A// / WILL BE A DUCT SEAL INSPECTION IN AREA "C". PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED TNSP 'DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS CONTINUED ONTO NEXT PAGE PREPARED 4/30/08, 14:05:02 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 5/01/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR '":BONIEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER:. 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P351 C9 4/01/08 BS C *PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A.ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BE C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/GS AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 `5,101/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 cJ" 'O '47p,5 WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D" COMMENTS AND NOTES PREPARED 5/01/08, 14:00:54 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 5/02/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLCOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete, DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BE C*MECH DUCT TIME: 17:00 VRU 001587138 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 08 4/10/08 BS C*MECH DUCT TIME: 17:00 VRU 001591577 4/10/08 AP WILL BE A MECHANICAL DUCT INSPECTION FOR "F-138" M457 09 4/23/08 BS C*MECH DUCT TIME: 17:00 VRU 001597947 4/23/08 AP hydronic pipe for area a & duct seal for area a as well as 2nd phase of area b M457 10 5/01/08 BS C*MECH DUCT TIME: 17:00 VRU 001601939 5/01/08 AP WILL BE A DUCT SEAL INSPECTION IN AREA "C". M463 01 5/5- 02/08 TT C*MECH OVERHEAD VRU 001602689 M457 11 5/ 2/08 T~ C*MECH DUCT TIME: 17:00 VRU 001602747 1-3;p O AND /NOTES PREPARED 5/06/08, 14:09:09 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/07/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND."D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B" P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252,-,fhGa✓ 24 - - C COMMENT NOTES ES PREPARED 5/14/08, 16:56:57 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/15/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA W. P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA - PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P339 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252 5/07/08 AP P351 13 5/15/08 TI ppp C*PLUMB ROUGH IN TIME: 17:00 VRU 001609965 S.~ WILL BE A WASTE AND VENT 2ND FLOOR AND THEY ALSO NEED AN ELEVATOR SHAFT INSPECTION FOR PLUMBING LINES. P359 23 5/1 08 TC*PLUMB OVERHEAD TIME: 17:00 VRU 001609957 WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" COMMENTS AND NOTES PREPARED 5/19/08, 15:45:21 INSPECTION TICKET PAGE 2 Harnett .County INSPECTOR: IVR DATE 5/20/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR:; BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER .4 J1i!fN-HARNETT COUNTY OF PHONE PARCEL . : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS parking lot lights south and east of site E257 01 5/20/088 TI C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 WILL BE THE E?.3CTPiCAL OVERHEAD SECOND FLOOR AREA "A". PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NOT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase P353 01 11/05/07 BS C*PLUMB WATER CONNECTION VRU 001515246 11/05/07 AP Ductile iron service pipe entering mech room P359 01 11/05/07 BS C*PLUMB OVERHEAD VRU 001515253 11/05/07 AP WASTE / VENT ~J LZ ~ CONTINUED ONTO NEXT PAGE --^U--L~------~---'V-/ PREPARED 5/19/08, 15:45:21 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 5/20/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER r: .JSeI--HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- ABEL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P359 12 3/18/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001578921 3/18/08 AP WILL BE A ROOF DRAIN INSPECTION FOR AREAS "C" AND "D". P359 13 3/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001580653 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252 5/07/08 AP P351 13 5/15/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001609965 5/15/08 AP WILL BE A WASTE AND VENT 2ND FLOOR AND THEY ALSO NEED AN ELEVATOR SHAFT INSPECTION FOR PLUMBING LINES. P359 23 5/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001609957 5/15/08 AP WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" ?359 24 5/20/08 ~TpI. C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 O-og bib WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". COMMENTS AND NOTES PREPARED 5/21/08, 16:25:24 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/22/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - 3/20/08 AP WILL BE FOR A PLUMBING ROOF DRAIN INSPECTION FOR AREA "C". P359 14 3/26/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001582931 3/26/08 AP WILL BE A CEILING WASTE AND VENT AND A ROOF DRAIN INSPECTION IN AREA "A". P351 08 3/28/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001584747 3/28/08 CA WILL BE A METAL WATERPIPE INSPECTION IN AREA "B" P351 09 4/01/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001586437 4/01/08 AP WILL BE A ROOF DRAIN INSPECTION AREA "A" P359 15 4/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001586445 4/01/08 AP WILL BE A, OVERHEAD WATER PIPING. P351 10 4/03/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001587997 4/03/08 AP WILL BE A ROOF DRAIN INSPECTION IN AREA "C". P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252 5/07/08 AP P351 13 5/15/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001609965 5/15/08 AP WILL BE X WASTE AND VENT 2ND FLOOR AND THEY ALSO NEED AN ELEVATOR SHAFT INSPECTION FOR PLUMBING LINES. P359 23 5/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001609957 5/15/08 AP WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" P359 24 5/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 5/20/08 CA WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". per curtis P359 25 5/2 08 C *PLUMB OVERHEAD TIME: 17:00 VRU 001613785 S'~ (lK WILL BE FOR THE OVERHEAD WATER SERVI COMMENTS AND NOTES PREPARED 5/22/08, 14:36:02 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/22/08 ADDRESS 55419 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR 'y BOItEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER , JAI -HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C169 01 4/18/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 A/22/06 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 ILD-- COMMENTS AND NOTES PREPARED 5/22/08, 14:04:24 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 5/23/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER r,JAI ~HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A". overhead for the max security cells upstairs only E257 02 5/23108 T~~J~j C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 1 -D 'YT l7\ ELECTRICAL ABOVE CEILING AREA "B". - - - COMMENTS AND NOTES PREPARED 5/28/08, 15:48:20 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 5/29/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A". overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/~/OQI COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 JIB MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". - - - COMMENTS AND NOTES PREPARED- 5/27/08, 14:19:33 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 5/28/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR :.BORDELUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER 'JAIL-11ARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - C169 01 4/18/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5 T~ y, C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615796 - c nLX~/J~~ YAPy IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials,.see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 6/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 8/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE GO AROUND 9:00. area "b" DWV test in chase CONTINUED ONTO NEXT PAGE - PREPARED 5/27/08, 14:19:33 INSPECTION TICKET PAGE 6 Harnett County. INSPECTOR: IVR DATE 5/28/08 - - - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER ::JAILNIARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - P359 24 5/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 5/20/08 CA WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". per curtis P359 25 5/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001613785 5/22/08 AP WILL BE FOR THE OVERHEAD WATER SERVICE P353 03 2 '08 I C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001615806 WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. ,VJ'lDJ - COMMENTS AND NOTES PREPARED 6/03/08, 14:53:24 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 6/04/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 5/28/08 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 07~/OS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 WILL BE A ROOF DRAIN INSPECTION TOWER "A" COMMENTS AND NOTES - PREPARED 6/04/08, 14:49:20 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 6/05/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR;-: Fx-'<DEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 10/10/07 AP completed all under slab inspections 10/10/07 E259 08 11/01/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001513829 11/07/07 AP ASKED FOR AN ELECTRICAL UNDER SLAB ROUGH IN. upstairs slab section a E255 04 11/07/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001516814 11/07/07 AP THIS WILL BE FOR THE OUTSIDE LIGHT POLES. PLEASE GO AS EARLY AS POSSIBLE*"*******************************"*** parking lot lights north and west side of sight E255 05 11/08/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001518083 11/08/07 AP WILL BE FOR THE POLE BASES. parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A" overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section h MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done, E257 03 6/05/08 C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. - - COMMENTS AND NOTES - PREPARED 6109108, 14:00:38 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 6/10/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAI0HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/0 TI C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 - ---2ND FLOOR WALL FRAMING PERMIT: CPEC 00 CP ELECTRICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - E255 01 6/13/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001428614 6/13/07 AP E267 01 6/20/07 BS C*ELEC TEMP SERVICE POLE VRU 001431535 6/20/07 AP WILL BE FOR THE SITE TRAILER. E259 01 6/27/07 BS C*ELEC UNDER SLAB VRU 001436484 6/27/07 AP for service entry and tele/cable E251 01 7/05/07 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001441286 7/05/07 CA CUSTOMER CALLED IN FOR AN ELECTRICAL INSPECTION ONLY. wrong inspection scheduled E255 02 7/05/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001441583 7/05/07 AP partial feeders (see electrical plan at site) E251 02 7/13/07 TI C*ELEC ROUGH IN TIME: 17:00 VRU 001445832 7/12/07 CA E259 02 7/13/07 LYM C*ELEC UNDER SLAB TIME: 17:00 VRU 001445964 7/13/07 AP E255 03 7/20/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001450790 7/23/07 AP WOULD LIKE THIS INSPECTION AT 9:00 AM. E259 03 8/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001464403 8/10/07 AP E259 04 9/05/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001479765 9/05/07 AP WOULD LIKE THIS IN THE MORNING. area "d" slab. Inspection also called for underslab electrical. Talked to electrical contractor about this, inspection must be done before slab prep. He said it wouldnt happen again. E259 05 9/12/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001484708 9/12/07 AP PARTIAL UNDERGROUND. service entrance conduits. E259 06 9/19/07 KS C*ELEC UNDER SLAB TIME: 17:00 VRU 001489202 9/19/07 AP WOULD LIKE THIS IN THE AFTERNOON. CONTINUED ONTO NEXT PAGE PREPARED 6/09/08, 14:00:38 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 6/10/08 ADDRESS : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR :.BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAILiHARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E259 07 10/10/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001502699 10/10/07 AP completed all under slab inspections 10/10/07 E259 08 11/01/07 BS C*ELEC UNDER SLAB TIME: 17:00 VRU 001513829 11/07/07 AP ASKED FOR AN ELECTRICAL UNDER SLAB ROUGH IN. upstairs slab section a E255 04 11/07/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001516814 11/07/07 AP THIS WILL BE FOR THE OUTSIDE LIGHT POLES. PLEASE GO AS EARLY AS POSSIBLE***********«************************* parking lot lights north and west side of sight E255 05 11/08/07 BS C*ELECTRICAL UNDERGROUND TIME: 17:00 VRU 001518083 11/08/07 AP WILL BE FOR THE POLE BASES. parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A" overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 /¢0 10 T C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - -457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/06 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". CONTINUED ONTO NEXT PAGE .`PREPARED 6/09/08, 14:00:38 INSPECTION TICKET PAGE 11 Harnett County INSPECTOR: IVR DATE 6110108 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL=HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B" second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587136 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 08 4/10/08 BS C*MECH DUCT TIME: 17:00 VRU 001591577 4/10/08 AP WILL BE A, MECHANICAL DUCT INSPECTION FOR "F-138" M457 09 4/23/08 BS C*MECH DUCT TIME: 17:00 VRU 001597947 4/23/08 AP hydronic pipe for area a & duct seal for area a as well as 2nd phase of area b M457 10 5/01/08 BS C*MECH DUCT TIME: 17:00 VRU 001601939 5/01/08 AP WILL BE A DUCT SEAL INSPECTION IN AREA "C". M463 01 5/02/08 BS C*MECH OVERHEAD VRU 001602689 5/02/08 AP M457 11 5/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001602747 5/02/08 AP M463 03 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622521 I0• 9 WILL BE FOR THE MECHANICAL CHASE "143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b - - CONTINUED ONTO NEXT PAGE - PREPARED 6/09/08, 14:00:38 INSPECTION TICKET PAGE 14 Harnett County INSPECTOR: IVR DATE 6/10/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR :.BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL=HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P359 16 4/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001587989 4/03/08 AP WILL BE THE OVERHEAD WATER IN AREAS "B" AND "D". P351 11 4/09/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001590629 4/09/08 AP ROOF DRAINS AREA "A" P359 17 4/09/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001590645 4/09/08 AP OVERHEAD WATER IN AREAS "B" AND "D" P351 12 4/10/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001591585 4/10/08 AP WILL BE FOR A PLUMBING ROUGH IN IN AREA "B". P353 02 4/15/08 TI C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001593557 4/15/08 CA PER MILTON, NEEDS WATER SERVICE ABOVE CEILING IN AREA "A". T/S: 04/14/2008 01:03 PM DJOHNSON P359 18 4/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001593896 4/15/08 AP overhead water distribution for the first floor in area "A" P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252 5/07/08 AP P351 13 5/15/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001609965 5/15/08 AP WILL BE A WASTE AND VENT 2ND FLOOR AND THEY ALSO NEED AN ELEVATOR SHAFT INSPECTION FOR PLUMBING LINES. P359 23 5/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001609957 5/15/08 AP WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" P359 24 5/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 5/20/08 CA WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". per curtis P359 25 5/22/08 BS C*PLUME OVERHEAD TIME: 17:00 VRU 001613785 5/22/08 AP WILL BE FOR THE OVERHEAD WATER SERVICE P353 03 5/28/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001615806 5/28/08 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 6/04/08 AP WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 6/04/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 6/04/08 AP WILL BE A ROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 T,,,,I~~~~,,,,//// hhhh C*PLUMB OVERHEAD TIME: 17:00 VRU 001622448 I/ WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.******************************* COMMENTS AND NOTES PREPARED 6/13/08, 14:01:14 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 6/16/08 - - - - - - - ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTP,ACTOP: a: BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6/16/08 _ T C*OVERHEAD ELE, MECH, PLB VRU 001625714 a ov WMrCTS ln; . < r' cS ~In ~I psi PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP - DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/06 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587138 CONTINUED ONTO NEXT PAGE PREPARED 6/13/08, 14:01:14 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 6/16/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOFBORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER!' JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 06 4/10/08 BS C*MECH DUCT TIME: 17:00 VRU 001591577 4/10/08 AP WILL BE A MECHANICAL DUCT INSPECTION FOR "F-138" M457 09 4/23/08 BS C*MECH DUCT TIME: 17:00 VRU 001597947 4/23/08 AP hydronic pipe for area a & duct seal for area a as well as 2nd phase of area b M457 10 5/01/08 BS C*MECH DUCT TIME: 17:00 VRU 001601939 5/01/08 AP WILL BE A DUCT SEAL INSPECTION IN AREA "C". M463 01 5/02/08 BS C*MECH OVERHEAD VRU 001602689 5/02/08 AP M457 11 5/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001602747 5/02/08 AP M463 03 6/10/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/1//6--/0 TI C*MECH ROUGH IN VRU 001625722 COMMENTS AND NOTES - PREPARED 6116108, 16:36:55 INSPECTION TICKET PAGE 2 Harnett Countt" INSPECTOR: IVR DATE 6/17/08 - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER `JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS parking lot lights south and east Of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A". . overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU#: 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/ /0~ TI, _ C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 PERMIT: CPIIC 0~0 CP INSULATION COMMMCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - I185 01 7/13/07 TI C *INSULATION INSPECTION VRU 001444603 7/11/07 CA 1185 02 6/17/08 TI C*INSULATION INSPECTION TIME: 17:00 VRU 001626654 '(7'D EXTERIOR WALL INSULATION. - COMMENTS AND NOTES FROM :ces FAX NO. :17046721121 Jun. 12 2008 03:32PM P1 =1 i Consultant Engineering Service, Inc. 8720 Red Oak Blvd. Suite 101 Tel: 704-672-1121 Charlotte, North Carolina 28217 Fax: 704-672-1556 FAX TRANSMITTAL SHEET TO: Brad Sutton FROM: Terry Davis FAX: 910-814-8277 FAX: 704672-1556 PHONE: PHONE: 704672-1121 SUB]EC!"; DATE: 6/12/08 REMARKS: I've enclosed the ground resistance test report for the grid ground at the Harnett County Detention Center. The resistance to ground was measured near the standby generator which is connected to the main 4/0 grid ground. The result of the test was under 2 ohms which is satisfactory to us. Please contact me if you have any questions. Thank you for your help. Terry Davis Consultant Engineering Service, Inc. e-mail: terry@ceseng.net ELECTRICAL HEATING & AIR CONDITIONING PLUMBING FROM :ceS FAX NO. :17046721121 Sun. 12 2008 03:32PM P2 uliraw LLYY ur. dr JL JYL JYUCL 11NML111 L1U1'111`111YU rNl~ UL E QUALM LIGHTIVWG PROTECTION, INC. June 6, 2008 NAME OF STRUCTURE OR BUILDING: Harnett Coun v 0ltention Center CONTRACT NUMBER: N/A DESCRIPTION QF SYSTEM BEING TEST GROUND LOOP TEST FOR OHMS READING: LIGHTNING PROTECTION SYSTEM INSPECTION: N/A ffia=s OE GROUNDING: 1.61 OHS hec ed 0 Grounding La Near h LIGHTNING PROTECTION SYSTEM INSPECTION: ALA. MME AND TITLE OF PERSON 1N CH Q3E OFQERFORMING TEST NAME: F d TITLE Pro eet Superintendent SIGNATURE~d~ F0 Bm 162 , RAlelok NC 77602 (ft9) an-9899 Faa (9191 W-8072 ry~v~yon "pr'n' ~ ,nr •'rx r. ,..,y,rv ...ra,'M1'^nP",~yt ro-kzp ,.n. q-ro-•':'~".p~'nytY{~F XPx'Y e.^~~d>tn ry,~:eria ti". ' e EXPIRE DATE / T 5117 TEMPORARY POWER CERTIFICATE JOB NAME ~(Ar nlf ~f~ f?'~ 1 1'l /1 OWNER ADDRESS 7S S -V) l PHONE LOCATION l , r °2u The power company shall'not'be required to terinate electric service supplied to the premises described above on or after („the" expiration date/.$pecified in-;this certificate, unless and until it is notified in writing by the Harnett County Electrical Inspector to do so. I'.the undersigned understand that this certificate is for Temporary Power only and that a final inspection is required before permanent power will be approved. I shall also comply with any 'special requirement, requested by the Harnett County Inspection Department. v Q ny o. , jar i r fro E <j~i C Co . Date ` / C 1 d0 r~'Ofi Owner or Authorized Signature This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code certifying at the time of issuance this structure was in temporary compliance.. with the.various ordinances`of the County of Harnett regulating building construction or use. Date ~P 7 Building Official 7 Cr' PRL!2ARED' 6/18/08, 16:17:45 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 6/19/08 - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M463 03 6/10/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6116108 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 I C*GAS PIPING TIME: 17:00 VRU 001628767 PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP P357 09 8/15/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001467604 6/15/07 AP WILL BE IN AREA A & C. P357 10 8/17/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001469592 8/17/07 AP FOR AREA A P351 01 9/27/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001494830 9/27/07 AP area d kitchen in wall dwv tests P351 02 10/10/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001502426 10/10/07 AP WILL BE THE PLUMBING IN THE WALL. various in wall dwv in all 4 areas P351 03 10/12/07 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001503507 10/12/07 AP WILL BE FOR THE WASTING VENT. AREA B. PLEASE JGO AROUND 9:00. CONTINUED ONTO NEXT PAGE PRSPREE' 6/18/08, 16:17:45 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 6/19/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - _ _ _ _ 5/15/08 AP WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" P359 24 5/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 5/20/08 CA WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". per curtis P359 25 5/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001613785 5/22/08 AP WILL BE FOR THE OVERHEAD WATER SERVICE P353 03 5/28/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001615806 5/28/08 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 6/04/08 AP WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 6/04/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 6/04/08 AP WILL BE A ROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001622446 6/10/08 AP WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.******************************* P353 05 /5 /1 /08 T,~~~~I~~~~jjjj! C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001628742 C7 WATER SERVICE AREA "A" CHASE. - - COMMENTS AND NOTES - - PREPARED 6/19/08, 15:52:28 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 6/20/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRAC 0R, :~AORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M463 03 6/10/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6/19/08 AP from meter through kitchen to firewall M457 12 6/20/08 C*MECH DUCT TIME: 17:00 VRU 001629617 ,V 0. DUCT INSPECTION CHASE 144. COMMENTS AND NOTES - PREPARED 6/19/08, 15:52:28 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 6/20/08 ADDRESS . :55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR :BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION 6 LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection M457 02 3/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001577162 3/14/08 DA WILL BE FOR THE MECHANICAL DUCT SEAL IN AREA "D" ALSO IN AREA "B" THEY HAVE 1 CHASE READY IN AREA B. End chase in area "B" for cells ok to insulate. Area "D" ductwork seal is incomplete. DO NOT INSULATE All area "B" dayrooms ok to insulate M457 03 3/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001580455 3/20/08 AP WOULD LIKE A DUCT CEILING INSPECTION IN AREA "D". M457 04 3/26/08 BS C*MECH DUCT TIME: 17:00 VRU 001582964 3/26/08 AP WILL BE FOR THE 2ND CHASE DUCT INSPECTION IN AREA "B". second chase in area B, upper portion only. M455 01 3/28/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001585116 3/28/08 AP Chiller pipe test for chiller/boiler mains in B/D corridor back to mech room and extending into last area B dayroom.(towards area A) Other 2 dayrooms not piped or tested. M457 05 3/28/08 BS C*MECH DUCT TIME: 17:00 VRU 001584739 3/28/08 AP WILL BE A'DUCT INSPECTION IN THE SECURE CORRIDOR. WOULD LIKE THIS IN THE MORNING. Duct in cooridor between areas A/D M455 02 4/02/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001587146 4/02/08 AP 100 PSI from boiler room through corridor and all of area " B" ok to insulate M457 06 4/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001587138 4/02/08 DA Area "C" Ductwork incomplete. Do not insulate M457 07 4/09/08 BS C*MECH.DUCT TIME: 17:00 VRU 001589878 4/09/08 AP WILL BE IN CHASE "C" 138 AND CHASE "F" 139. M457 08 4/10/08 BS C*MECH DUCT TIME: 17:00 VRU 001591577 4/10/08 AP WILL BE A MECHANICAL DUCT INSPECTION FOR "F-138" M457 09 4/23/08 BS C*MECH DUCT TIME: 17:00 VRU 001597947 4/23/08 AP hydronic pipe for area a & duct seal for area a as well as 2nd phase of area b M457 10 5/01/08 BS C*MECH DUCT TIME: 17:00 VRU 001601939 5/01/08 AP WILL BE A DUCT SEAL INSPECTION IN AREA "C". M463 01 5/02/08 BS C*MECH OVERHEAD VRU 001602689 5/02/08 AP M457 11 5/02/08 BS C*MECH DUCT TIME: 17:00 VRU 001602747 5/02/08 AP - - CONTINUED ONTO NEXT PAGE - - PREPARED 6/24*08, 14:11:50 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 6/24/08 - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P359 19 4/17/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001596030 4/18/08 AP AREAS C & A roof drains and vent stacks area a and c P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252 5/07/08 AP P351 13 5/15/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001609965 5/15/08 AP WILL BE A WASTE AND VENT 2ND FLOOR AND THEY ALSO NEED AN ELEVATOR SHAFT INSPECTION FOR PLUMBING LINES. P359 23 5/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001609957 5/15/08 AP WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" P359 24 5/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 5/20/08 CA WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". per curtis P359 25 5/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001613785 5/22/08 AP WILL BE FOR THE OVERHEAD WATER SERVICE P353 03 5/28/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001615806 5/28/08 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 'dS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 6/04/08 AP WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 6/04/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 6/04/08 AP WILL BE A ROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001622448 6/10/08 AP WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.******************************* P353 05 6/19/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001628742 6/19/08 AP WATER SERVICE AREA "A" CHASE. P351 14 -6/24/08 TI C*PLUMB ROUGH IN TIME: 17:00 VRU 001631084 deR<' MILTON SAID THAT THIS WOULD BE FOR A PLUMBING CHANGE ORDER ROUGH IN FOR THE 2ND FLOOR. IF I DID NOT RUN THIS CORRECTLY LET ME KNOW. NJT COMMENTS AND NOTES PREPARED _6/24108, 14:11:50 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 6/24/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/17/08 BS C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 6/17/08 AP temp power cert attached as well as GEC resistance test E251 04 6/24/08 TI C*ELEC ROUGH IN TIME: 17:00 VRU 001631076 4-.N-4 zWX - WILL BE AN ELECTRICAL IN WALL AND A METAL STUD FRAMING FOR THE FIRST FLOOR. PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND CONTINUED ONTO NEXT PAGE PREPARED 6/27/08, 14:00:15 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 6/30/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6116108 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6/16/08 AP above ceiling ducts in kitchen. C167 02 6~/~3~j0//008 T~,I//~~ / C*WALL INSPECTION TIME: 17:00 VRU 001633999 ~2 Q~ WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx - - - - - - - _ - COMMENTS AND NOTES PREPARED 6/30/08, 14:16:24 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 7/01/08 - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A" C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6/16/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6/16/08 AP above ceiling ducts in kitchen. C167 02 6/30/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001633999 6/30/08 AP WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx C167 03 7.01/08 C*WALL INSPECTION TIME: 17:00 VRU 001634500 '~T COMMENTS AND NOTES 1 PREPAR 7/02/08, 14:31:32 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: BRAD SUTTON DATE 7/03/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-4ARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 11/08/07 AP WILL BE FOR THE POLE BASES. parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/06 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A" overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/06 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/17/08 BS C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 6/17/08 AP temp power cert attached as well as GEC resistance test E251 04 6/24/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001631076 6/24/08 AP WILL BE AN ELECTRICAL IN WALL AND A METAL STUD FRAMING FOR THE FIRST FLOOR. inwall downstairs section A E251 05 7/03/08 B/g/yJ~ C*ELEC ROUGH IN TIME: 17:00 VRU 001636174 7•~ Ok J ELE UP IN AREA C PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP CONTINUED ONTO NEXT PAGE PRIMP, 7/02/06, 14:31:32 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: BRAD SUTTON DATE 7/03/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-11ARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P359 28 7/03/08 B$ ter,. C*PLUMB OVERHEAD TIME: 17:00 VRU 001636331 ~111`IJ9$1 H-A LOCATION COMMENTS AND NOTES PRIPARH'1 7/07/08, 14:04:58 INSPECTION TICKET PAGE 6 Harriett County INSPECTOR: IVR DATE 7/08/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M463 03 6/10/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE "143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6/19/08 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143 lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 ~17/p0~8/08 TI C*MECH DUCT VRU 001637834 ('Q O ~~S DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D COMMENTS AND NOTES - - PREPARED 7/09/08, 16:46:40 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 7/10/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE PARCEL :,11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPIC 00 CP INSULATION COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS I185 01 7/13/07 TI C*INSULATION INSPECTION VRU 001444603 7/11/07 CA 1185 02 6/17/08 BS C*INSULATION INSPECTION TIME: 17:00 VRU 001626654 6/17/08 AP EXTERIOR WALL INSULATION. exterior stud walls on second floor only 1185 03 3./10/08 TI C*INSULATION INSPECTION TIME: 17:00 VRU 001639863 0' RE NEEDS INSULATION IN AREA C, AND AREA A FIRST FLOOR. COMMENTS AND NOTES - PREPARED 7/14/08, 14:03:35 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 7/15/08 - - - - - - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTPR .ORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P359 20 4/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001597228 4/22/08 AP WILL BE FOR THE WATER OVERHEAD AREA "B" 3RD CHASE. also overhead for kitchen area P359 21 5/01/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001601913 5/01/08 AP WILL BE FOR A ROUGH IN WATER OVERHEAD.AREAS "B" AND "D". P359 22 5/07/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001605252 5/07/08 AP P351 13 5/15/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001609965 5/15/08 AP WILL BE A WASTE AND VENT 2ND FLOOR AND THEY ALSO NEED AN ELEVATOR SHAFT INSPECTION FOR PLUMBING LINES. P359 23 5/15/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001609957 5/15/08 AP WILL BE A ROOF DRAIN UPSTAIRS. 2ND FLOOR AREA "A" P359 24 5/20/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001612282 5/20/08 CA WANTS A PLUMBING ROOF DRAIN IN AREA "A" AND A OVERHEAD WATER CONNECTION AREA "C". per curtis P359 25 5/22/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001613785 5/22/08 AP WILL BE FOR THE OVERHEAD WATER SERVICE P353 03 5/28/08 BS C*PLUMBWATER CONNECTION TIME: 17:00 VRU 001615806 5/28/08 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 6/04/08 AP WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 6/04/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 6/04/08 AP WILL BE AROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001622448 6/10/08 AP WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.******************************* P353 05 6/19/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001628742 6/19/08 AP WATER SERVICE AREA "A" CHASE. P351 14 6/24/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001631084 6/24/08 AP MILTON SAID THAT THIS WOULD BE FOR A PLUMBING CHANGE ORDER ROUGH IN FOR THE 2ND FLOOR. IF I DID NOT RUN THIS CORRECTLY LET ME KNOW. NJT added a sink in upstairs breakroom P359 28 7/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001636331 7/03/08 AP B-A LOCATION pressure test on main and all areas of a-b P353 06 7 15/_08 TI,,//,~, C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001641588 ~f O {~yi WILL BE FOR THE WATER LINE IN AREA /"9A" \ eeO - - COMMENTS AND NOTES PREPARED 7/14/08, 14:03:35 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 7/15/08 - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR ,70RDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6119108 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143 lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 7/08/08 BS C*MECH DUCT VRU 001637834 7/08/08 AP DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D M455 03 7/15/08 T~In C*MECH CHILLER PIPING TIME: 17:00 VRU 001641315 WOULD ALSO LIKE THE HOT WATER LINE INSPECTED ALSO. WILL BE AREA "A". PERMIT: CPPC 00 CP PLUMBING COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS P357 01 6/20/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001432178 6/20/07 AP AREA B WOULD LIKE INSPECTION AROUND 11:00. partials, see plumbers plan for info P357 02 6/25/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001434414 6/25/07 AP WOULD LIKE THIS INSPECTION FIRST THING IN THE MORNING. partial area b P357 03 7/06/07 BS C*PLUMB UNDER SLAB TIME: 08:00 VRU 001441328 7/12/07 AP P357 04 7/13/07 LYM C*PLUMB UNDER SLAB TIME: 17:00 VRU 001445634 7/13/07 AP P357 05 7/23/07 KS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001451251 7/23/07 AP Wants inspection around 9:00. Highlighted and initialed plumbers plan. P363 01 7/24/07 TI C*PLUMB GREASE TRAP TIME: 17:00 VRU 001452481 7/25/07 AP per brad P357 06 8/07/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001460948 8/07/07 AP THIS INSPECTION WILL BE FOR AREA C. NJT P357 07 8/08/07 BS C*PLUMB-UNDER SLAB TIME: 17:00 VRU 001462977 8/08/07 AP MITLON ASKED FOR A PLUMBING UNDERGROUND T/S: 08/07/2007 03:47 PM DJOHNSON P357 08 8/09/07 BS C*PLUMB UNDER SLAB TIME: 17:00 VRU 001463769 8/09/07 AP - - CONTINUED ONTO NEXT PAGE PREPARED 7/16/08, 16:10:24 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 7/17/08 - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC, PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - M463 03 6110108 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6119108 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6/19/08 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143 lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 7/08/08 BS C*MECH DUCT VRU 001637834 7/08/08 AP DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D M455 03 7/15/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001641315 7/15/08 AP WOULD ALSO LIKE THE HOT WATER LINE INSPECTED ALSO. WILL BE AREA "A". M455 04 7/16/08 TI C*MECH CHILLER PIPING TIME: 17:00 VRU 001644129 ?'~~t'D ~g CHILLER PIPING AREA C M457 15 7/17/~08~ I C*MECH DUCT TIME: 17:00 VRU 001644137 L95 WILL HE FOR THE DUCT SEAL INSPECTION IN CHASE - COMMENTS AND NOTES PREPARED 7/21/08, 14:59:08 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 7/22/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C169 01 4/18/08 BS C-OVERHEAD ELE, MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6/16/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6116108 AP above ceiling ducts in kitchen. C167 02 6/30/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001633999 6/30/08 AP WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx C167 03 7/01/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001634500 7/01/08 DA dispatch not insulated C153 03 7/22/08 TI C*BLDG ROUGH IN TIME: 17:00 VRU 001646512 7 •Q WILL BE IN AREA C. COMMBRCrnr• PERMIT: CPIC 00 CP INTR REQU TED DESCRIPTION TYP/SQ COMP ETED RESULTS/COMMENTS ------I185 01 7/ 3/07 C*INSULATION INSPECTION VRU 001444603 7/ 1/07 I185 02 6/ 7/08 C*INSULATION INSPE CTION TIME: 17:00 VRU 001626654 6 17/08 EXTERIOR WALL INSULATION. exterior stud walls on second floor only 1185 03 7 10/08 S C*INSULATION INSPECTION TIME: 17:00 VRU 001639863 7 10/08 NEEDS INSULATION IN AREA C, AND AREA A FIRST FLOOR. insulation in dispatch area ok...area "c" ok except above entry windows, this will be insulated and inspected at a later date 1185 04 7 22/08 I C-INSULATION INSPECTION TIME: 17:00 VRU#: 001646520 - - - COMMENTS AND NOTES - 1 - PREPARED 7/23/08, 12:12:20 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 7/23/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 6/04/08 AP WILL BE A ROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001622448 6/10/08 AP WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.******************************* P353 05 6/19/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001628742 6/19/08 AP WATER SERVICE AREA "A" CHASE. P351 14 6/24/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001631084 6/24/08 AP MILTON SAID THAT THIS WOULD BE FOR A PLUMBING CHANGE ORDER ROUGH IN FOR THE 2ND FLOOR. IF I DID NOT RUN THIS CORRECTLY LET ME KNOW. NJT added a sink in upstairs breakroom P359 28 7/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001636331 7/03/08 AP B-A LOCATION pressure test on main and all areas of a-b P353 06 7/15/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001641588 7/15/08 AP WILL BE FOR THE WATER LINE IN AREA "A" P359 29 7/23/08 lwI~~l C*PLUMB OVERHEAD TIME: 17:00 VRU 001647718 7 -A-09 COMMENTS AND NOTES PREPARED 7/23/08, 14:00:29 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 7/24/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS _ C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6/19/08 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143 lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 7/08/08 BS C*MECH DUCT VRU 001637834 7/08/08 AP DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D M455 03 7/15/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001641315 7/15/08 AP WOULD ALSO LIKE THE HOT WATER LINE INSPECTED ALSO. WILL BE AREA "A". M455 04 7/16/08 TI C*MECH CHILLER PIPING TIME: 17:00 VRU 001644129 7/23/08 CA CHILLER PIPING AREA C M457 15 7/17/06 BS C*MECH DUCT TIME: 17:00 VRU 001644137 7/17/08 DA WILL BE FOR THE DUCT SEAL INSPECTION IN CHASE kitchen.hood duct welds to like swiss cheese. M457 16 7/23/08 TI "C*MECH-DUCT TIME: 17:00 VRU 001647403 7/23/08 CA KITCHEN EXHAUST INSPECTION. M457 17 7 24/08 C*MECH DUCT TIME: 17:00 VRU 001647742 0 COMMENTS AND NOTES - v ~l V\ll PREPARED 7/28/08, 14:04:08 INSPECTION TICKET PAGE 3 1Harn&tt County INSPECTOR: IVR DATE 7/29/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A" overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/17/08 BS C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 6/17/08 AP temp power cert.attached as well as GEC resistance test E251 04 6/24/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001631076 6/24/08 AP WILL BE AN ELECTRICAL IN WALL AND A METAL STUD FRAMING FOR THE FIRST FLOOR. inwall downstairs section A E251 05 7/03/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001636174 7/03/08 AP ELE UP IN AREA C area c metal stud in wall rough in E257 04 7/29/08 TI C*ELEC OVERHEAD TIME: 17:00 VRU 001650647 AREA C ABOVE CEILING COMMENTS AND NOTES PREPARED 8/01/08, 7:57:51 INSPECTION TICKET PAGE 2 Harnett (_)unty INSPECTOR: IVR DATE 8/01/08 r` ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 11/08/07 AP WILL BE FOR THE POLE BASES. parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A" overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B" dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/17/08 BS C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 6/17/08 AP temp power cert attached as well as GEC resistance test E251 04 6/24/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001631076 6/24/08 AP WILL BE AN ELECTRICAL IN WALL AND A METAL STUD FRAMING FOR THE FIRST FLOOR. inwall downstairs section A E251 05 7/03/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001636174 7/03/08 AP ELE UP IN AREA C area c metal stud in wall rough in E257 04 7/29/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001650647 7/29/08 AP AREA C ABOVE CEILING E251 06 .8/01/08 C*ELEC ROUGH IN TIME: 17:00 VRU 001654268 , 1~ff CONTROL ROOM AND BATHROON INSPECTION T/S: 07/31/2008 03:58 PM DJOHNSON CONTINUED ONTO NEXT PAGE - PREPARED 8/01/08, 7:57:51 INSPECTION TICKET PAGE 4 Harnett ('~unty INSPECTOR: IVR DATE 8/01/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M463 03 6/10/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6110108 AP WILL BE FOR THE MECHANICAL CHASE "143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6/19/08 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143 lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 7/08/08 BS C*MECH DUCT VRU 4: 001637834 7/08/08 AP DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D M455 03 7/15/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001641315 7/15/08 AP WOULD ALSO LIKE THE HOT WATER LINE INSPECTED ALSO. WILL BE AREA "A". M455 04 7/16/08 TI C*MECH CHILLER PIPING TIME: 17:00 VRU 001644129 7/23/08 CA CHILLER PIPING AREA C M457 15 7/17/08 BS C*MECH DUCT TIME: 17:00 VRU 001644137 7/17/08 DA WILL BE FOR THE DUCT SEAL INSPECTION IN CHASE kitchen hood duct welds to like swiss cheese. M457 16 7/23/08 TI C*MECH DUCT TIME: 17:00 VRU 001647403 7/23/08 CA KITCHEN EXHAUST INSPECTION. M457 17 7/24/08 BS C*MECH DUCT TIME: 17:00 VRU 001647742 7/24/08 DP still holes in kitchen exhaust. Close off roof fans, close off duct and fill with smoke. Once all the holes are fixed, reschedule and have duct closed and ready to be smoked for inspection. $50 re fee this was trip #3 M455 05 /01/08 TI C*MECH CHILLER PIPING TIME: 17:00 VRU 001654433 'j l7 g5 above ceiling piping on second floor ~~r T/S: 08/01/2008 07:57 AM DJOHNSON M457 18 8/ /08 TJ/ C*MECH DUCT TIME: 17:00 VRU 001654243 III,/~~ CHASE 144 AND VESTIBULE COMMENTS AND NOTES PREPARED 8/04/08, 13:59:50 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 8/05/08 ADDRESS 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR -ORDEitj;X CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 6/19/08 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT 'TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143~lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 7/08/08 BS C*MECH DUCT' VRU 001637834 7/08/08 AP DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D M455 03 7/15/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001641315 7/15/08 AP WOULD ALSO LIKE.THE HOT WATER LINE INSPECTED-ALSO. WILL BE AREA "A". M455 04 7/16/08 TI C*MECH CHILLER PIPING TIME: 17:00 VRU 001644129 7/23/08 CA CHILLER PIPING AREA C M457 15 7/17/08 BS C*MECH DUCT TIME: 17:00 VRU 001644137 7/17/08 DA WILL BE FOR THE DUCT SEAL INSPECTION IN CHASE kitchen hood duct welds to like swiss cheese. M457 16 7/23/08 TI C*MECH DUCT TIME: 17:00 VRU 001647403 7/23/08 CA KITCHEN EXHAUST INSPECTION. M457 17 7/24/08 BS C*MECH DUCT TIME: 17:00 VRU 001647742 7/24/08 DP still holes in kitchen exhaust. Close off roof fans, close off duct and fill with smoke. Once all the holes are fixed, reschedule and have duct closed and ready to be smoked for inspection. $50 re fee this was trip #3 M455 05 8/01/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001654433 8/01/08 AP above ceiling piping on second floor T/S: 08/01/2008 07:57 AM DJOHNSON chiller piping completed M457 18 8/01/08 BS C*MECH DUCT TIME: 17:00 VRU 001654243 8/01/08 AP CHASE 144 AND VESTIBULE chiller piping completed M457 19 fl 05/08 T C*MECH DUCT TIME: 17:00 VRU 001655869 C D WILL BE FOR A MECHANICAL DUCT INSPECTION ON THE 2ND FLOOR. M463 04 8/ 5/OB T C*MECH OVERHEAD TIME: 17:00 VRU 001655968 WILL BE FOR THE KITCHEN HOOD DUCT INSPECTION.HTE WOULD NOT LET ME SCHEDULE THIS ANY OTHER WAY. - COMMENTS AND NOTES - - - PREPARED 8/04/08, 13:59:50 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR; IVR DATE 8/05/08 - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDETjUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER ; JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A". overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL'ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building-and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/17/08 BS C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 6/17/08 AP temp power cert attached as well as GEC resistance test E251 04 6/24/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001631076 6/24/08 AP WILL BE AN ELECTRICAL IN WALL AND A METAL STUD FRAMING FOR THE FIRST FLOOR. inwall downstairs section A E251 05 7/03/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001636174 7/03/08 AP ELE UP IN AREA C area c metal stud in wall rough in E257 04 7/29/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001650647 7/29/08 AP AREA C ABOVE CEILING E251 06 8/01/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001654268 8/04/08 AP CONTROL ROOM AND BATHROON INSPECTION T/S: 07/31/2008 03:58 PM DJOHNSON controll room for max security E257 05 8/05/08 TI C*ELEC OVERHEAD TIME: 17:00 VRU 001655851 $-S o~ WILL BE AN ELECTRICAL ABOVE CEILING ROUGH IN THE KITCHEN. PERMIT: CPMC 00 CP MECHANICAL COMMERCIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - M457 01 2/14/08 BS C*MECH DUCT TIME: 17:00 VRU 001563378 2/15/08 AP area b overhead duct inspection - CONTINUED ONTO NEXT PAGE PREPARED 8/18/08, 16:26:48 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 8/19/08 - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C169 01 4/18/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6/16/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6/16/08 AP above ceiling ducts in kitchen. C167 02 6/30/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001633999 6130108 AP WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. xxxxxxxxxxxx*xxxxxxxxxxxxxxxxxxxxxxxxxxxxx C167 03 7/01/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001634500 7/01/08 DA dispatch not insulated C153 03 7/22/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001646512 7/22/08 AP WILL BE IN AREA C. framing over entrance to area c C165 07 7/23/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001647395 7/23/08 CA WANTS A ROUGH IN ABOVE CEILING & WASTE AND VENT. AREA "A" MISC 04 8/19/08 TI COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001664317 MILTON ASKED FOR A PLUMBING GAS LINE INSPECTION FOR THE WHOLE BUILDING, IN THE MORNING. _`_4'----------------- COMMENTS AND NOTES PREPARED 8/19/08, 15:09:03 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 8/20/08 - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS M463 03 6/10/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001622521 6/10/08 AP WILL BE FOR THE MECHANICAL CHASE 11143" DUCT INSPECTION AND THE MAIN QUARTER DUCT INSPECTION. M463 02 6/10/08 TI C*MECH OVERHEAD TIME: 17:00 VRU 001622513 6/09/08 CA M459 01 6/16/08 BS C*MECH ROUGH IN VRU 001625722 6/16/08 AP duct chase 143 in section a. M451 01 6/19/08 BS C*GAS PIPING TIME: 17:00 VRU 001628767 6119106 AP from meter through kitchen to firewall M457 12 6/20/08 BS C*MECH DUCT TIME: 17:00 VRU 001629617 6/20/08 AP DUCT INSPECTION CHASE 144. chase 143 lower M457 13 6/25/08 BS C*MECH DUCT TIME: 17:00 VRU 001631910 6/25/08 CA KITCHEN HOOD DUCT. IN THE MORNING. per milton (kitchen hood) M457 14 7/08/08 BS C*MECH DUCT VRU 001637834 7/08/08 AP DUCT 1ST FLOOR / DUCT CHASE 143 / DISHWASHER DUCT IN KIC. AREA D M455 03 7/15/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001641315 7/15/08 AP WOULD ALSO LIKE THE HOT WATER LINE INSPECTED ALSO. WILL BE AREA "A". M455 04 7/16/08 TI C*MECH CHILLER PIPING TIME: 17:00 VRU 001644129 7/23/08 CA CHILLER PIPING AREA C M457 15 7/17/08 BS C*MECH DUCT TIME: 17:00 VRU 001644137 7/17/08 DA WILL BE FOR THE DUCT SEAL INSPECTION IN CHASE kitchen hood duct welds to like swiss cheese. M457 16 7/23/08 TI C*MECH DUCT TIME: 17:00 VRU 001647403 7/23/08 CA KITCHEN EXHAUST INSPECTION. M457 17 7/24/08 BS C*MECH DUCT TIME: 17:00 VRU 001647742 7/24/08 DP still holes in kitchen exhaust. Close off roof fans, close off duct and fill with smoke. Once all the holes are fixed, reschedule and have duct closed and ready to be smoked for inspection. $50 re fee this was trip #3 M455 05 8/01/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001654433 8/01/08 AP above ceiling piping on second floor T/S: 08/01/2008 07:57 AM DJOHNSON chiller piping completed M457 18 8/01/08 BS C*MECH DUCT TIME: 17:00 VRU 001654243 8/01/08 AP CHASE 144 AND VESTIBULE chiller piping completed M457 19 8/05/08 BS C*MECH DUCT TIME: 17:00 VRU 001655869 8/05/08 AP WILL BE FOR A MECHANICAL DUCT INSPECTION ON THE 2ND FLOOR. M463 04 8/05/08 BS C*MECH OVERHEAD TIME: 17:00 VRU 001655968 8/05/08 AP WILL BE FOR THE KITCHEN HOOD DUCT INSPECTION.HTE WOULD NOT LET ME SCHEDULE THIS ANY OTHER WAY. M457 20 8/.~2~ 0/~09 8 TI C*MECH DUCT TIME: 17:00 VRU 001665256 ~p ERs WILL BE FOR THE FRONT LOBBY DUCT INSPECTION. COMMENTS AND NOTES - PREPARED 8/22/08, 13:59:55 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 8/25/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ceiling supply boots in lobby M455 06 8/25/08 TI,,,,}}}}~~~~yyyy C*MECH CHILLER PIPING TIME: 17:00 VRU 001666965 .12~pf MILTON ASKED FOR A CHILLER WATER INSPECTION AND A "VAV" BOX INSPECTION IN AREA C. COMMENTS AND NOTES PREPARED 10/01/08, 14:02:58 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 10/02/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8/20/08 AP WILL BE FOR THE FRONT LOBBY DUCT INSPECTION. ceiling supply boots in lobby M455 06 8/25/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001666965 8/25/08 AP MILTON ASKED FOR A CHILLER WATER INSPECTION AND A "VAV" BOX INSPECTION IN AREA C. M451 02 10 0 T,T.,,~~, C*GAS PIPING TIME: 17:00 VRU 001685700 1-4 ' ~Ja WANTS GAS PIPING FOR PLUMBING. COMMENTS AND NOTES PREPARED 10/15/08, 15:57:49 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 10/16/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 3/11/08 CA ABOVE CEILING IN THE KITCHEN. C169 01 4/18/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEA) FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR,WALL FRAMING. second floor wall framing C169 02 6/16/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6/16/08 AP above ceiling ducts in kitchen. C167 02 6/30/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001633999 6/30/08 AP WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx C167 03 7/01/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001634500 7/01/08 DA dispatch not insulated C153 03 7/22/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001646512 7/22/08 AP WILL BE IN AREA C. framing over entrance to area c C165 07 7/23/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001647395 7/23/08 CA WANTS A ROUGH IN ABOVE CEILING & WASTE AND VENT. AREA "A" MISC 04 8/19/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001664317 8/19/08 AP MILTON ASKED FOR A PLUMBING GAS LINE INSPECTION FOR THE WHOLE BUILDING, IN THE MORNING. Entire line from mech room to meter. 60 PSI held for 3 days C169 03 10/16/08 TI_T„ C*OVERHEAD ELE, MECH, PLB TIME: 17:00 VRU 001693274 - - COMMENTS AND NOTES - - - ~I PREPARED fi 1/24/,08, 16:38:47 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: BRAD SUTTON DATE 11/25/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - P353 03 5/28/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001615806 5/28/06 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 6/04/08 AP WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 6/04/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 6/04/08 AP WILL BE A ROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001622448 6/10/08 AP WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.*+****************+************ P353 05 6/19/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001628742 6/19/08 AP WATER SERVICE AREA "A" CHASE. P351 14 6/24/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001631084 6/24/08 AP MILTON SAID THAT THIS WOULD BE FOR A PLUMBING CHANGE ORDER ROUGH IN FOR THE 2ND FLOOR. IF I DID NOT RUN THIS CORRECTLY LET ME KNOW. NJT added a sink in upstairs breakroom P359 28 7/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001636331 7/03/08 AP B-A LOCATION pressure test on main and all areas of a-b P353 06 7/15/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001641588 7/15/08 AP WILL BE FOR THE WATER LINE IN AREA "A" P359 29 7/23/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001647718 7/23/08 AP all rough ins complete P359 30 8/01/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001654250 8/01/08 CA ABOVE CEILING PIPING ON SECOND FLOOR T/S: 07/31/2008 03:58 PM DJOHNSON P361 01 11/21/08 BS C*PLUMB FINAL TIME: 17:00 VRU 001708536 11/21/08 AP PLUMBING FINALS DONE IN SECTIONS: AREA B AND SECURE CORRIDOR cell block "B" P361 02 11/ 08 BS C*PLUMB FINAL TIME: 17:00 VRU 001710318 Q dles PLUMBING FINAL FOR AREA C AND D T/S: 11/24/2008 04:38 PM DJOHNSON COMMENTS AND NOTES - PREPARED 12/08/08, 13:59:15 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 12/09/08 - - - - - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - C169 01 4/18/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "Au C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6/16/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6/16/08 AP above ceiling ducts in kitchen. C167 02 6/30/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001633999 6/30/08 AP WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. C167 03 7/01/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001634500 7/01/08 DA dispatch not insulated C153 03 7/22/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001646512 7/22/08 AP WILL BE IN AREA C. framing over entrance to area c C165 07 7/23/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001647395 7/23/08 CA WANTS A ROUGH IN ABOVE CEILING & WASTE AND VENT. AREA "A" MISC 04 8/19/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001664317 8/19/08 AP MILTON ASKED FOR A PLUMBING GAS LINE INSPECTION FOR THE WHOLE BUILDING, IN THE MORNING. Entire line from mech room to meter. 60 PSI held for 3 days C169 03 10/16/08 BS C*OVERHEAD ELE, MECH, PLB TIME: 17:00 VRU 001693274 10/16/08 AP C169 04 12/09/08 TI C*OVERHEAD ELE, MECH, PLB TIME: 17:00 VRU 001714484 .I?-s0-9~ _W WILL BE AREA "A" FOR THE SECURE CORRIDOR. - COMMENTS AND NOTES PREPARED 12/10/08, 14:00:36 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 12/11/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - 8/20/08 AP WILL BE FOR THE FRONT LOBBY DUCT INSPECTION. ceiling supply boots in lobby M455 06 8/25/08 BS C*MECH CHILLER PIPING TIME: 17:00 VRU 001666965 8/25/08 AP MILTON ASKED FOR A CHILLER WATER INSPECTION AND A "VAV" BOX INSPECTION IN AREA C. M451 02 10/02/08 BS C*GAS PIPING TIME: 17:00 VRU 001685700 10/02/08 AP WANTS GAS.PIPING FOR PLUMBING. entire gas system tested under 50 psi, except regulator connections and meter connection. Will test these after gas is applied using a gas leak detection method M459 02 10/21/08 BS C*MECH ROUGH IN TIME: 17:00 VRU 001695170 10/21/08 AP WILL BE FOR THE ROOF TOP UNIT. rooft M465 01 12/11/08 T~ C*MECH FINAL TIME: 17:00 VRU 001715861 DOSI A~/1pJc- - - - - COMMENTS AND NOTES - - PREPAR9D 12/16/08, 16:18:11 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 12/17/08 - - - - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - 5/28/08 AP WATER SERVICE ABOVE CEILING AND IN WALL AREA A 2ND FLOOR AND ABOVE CEILING WATER SERVICE AREA C. P353 04 6/04/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001619717 6/04/08 AP WILL BE FOR A WATER SERVICE SECTION 1 AREA "A" P359 26 6/04/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001619725 6/04/08 AP WILL BE A ROOF DRAIN INSPECTION TOWER "A" P359 27 6/10/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001622448 6/10/08 AP WILL BE THE PLUMBING ROOF DRAIN IN AREA "A" AND "C". THIS WILL BE THE FINAL ON THIS.*************************+***+* P353 05 6/19/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001628742 6/19/08 AP WATER SERVICE AREA "A" CHASE. P351 14 6/24/08 BS C*PLUMB ROUGH IN TIME: 17:00 VRU 001631084 6/24/08 AP MILTON SAID THAT THIS WOULD BE FOR A PLUMBING CHANGE ORDER ROUGH IN FOR THE 2ND FLOOR. IF I DID NOT RUN THIS CORRECTLY LET ME KNOW. NJT added a sink in upstairs breakroom P359 28 7/03/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001636331 7/03/08 AP B-A LOCATION pressure test on main and all areas of a-b P353 06 7/15/08 BS C*PLUMB WATER CONNECTION TIME: 17:00 VRU 001641588 7/15/08 AP WILL BE FOR THE WATER LINE IN AREA "A" P359 29 7/23/08 BS C*PLUMB OVERHEAD TIME: 17:00 VRU 001647718 7/23/08 AP all rough ins complete P359 30 8/01/08 TI C*PLUMB OVERHEAD TIME: 17:00 VRU 001654250 8/01/08 CA ABOVE CEILING PIPING ON SECOND FLOOR T/S: 07/31/2008 03:58 PM DJOHNSON P361 01 11/21/08 BS C*PLUMB FINAL TIME: 17:00 VRU 001708536 11/21/08 AP PLUMBING FINALS DONE IN SECTIONS: AREA H AND SECURE CORRIDOR cell block "B" P361 02 11/25/08 BS C*PLUMB FINAL TIME: 17:00 VRU 001710318 11/25/08 AP PLUMBING FINAL FOR AREA C AND D T/S: 11/24/2008 04:38 PM DJOHNSON P361 03 12L17/08 TI `C*PLUMB FINAL TIME: 17:00 VRU 001717974 MILTON IS REQUESTING A FINAIPLUMBING ON SEC A 1ST AND 2ND FLOOR AND A GAS FINAL. T/S: 12/16/2008 04:17 PM DJOHNSON - - COMMENTS AND NOTES - PREPARED 12/16/08, 16:18:11 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 12/17/08 - - ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 11/08/07 AP WILL BE FOR THE POLE BASES. parking lot lights south and east of site E257 01 5/20/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001612092 5/20/08 AP WILL BE THE ELECTRICAL OVERHEAD SECOND FLOOR AREA "A". overhead for the max security cells upstairs only E257 02 5/23/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001614403 5/22/08 AP ELECTRICAL ABOVE CEILING AREA "B". dayroom areas in section b MISC 01 5/29/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001616846 5/29/08 DA MAIN ELECTRICAL SERVICE TRANSFORMERS AREA "D". service equipment for building and chillers ok, grounding electrode system is incomplete. Cannot release power until grounding system is complete and resistance testing has been done E257 03 6/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001620624 6/05/08 AP WILL BE AN ABOVE CEILING FOR THE "F" DORM AND THE "A" MAIXIMUM SECURITY. E251 03 6/10/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001622463 6/10/08 AP THIS WILL BE FOR THE 2ND FLOOR ELECTRICAL IN WALL ROUGH. ALSO NEED THE MAIN TRANSFORMER INSPECTED FOR AN ADDITIONAL WIRE PER ELECTRIC COMPANY. second floor in wall and overhead in dayroom cells on female side E253 01 6/17/08 BS C*ELEC TEMP POWER CERT TIME: 17:00 VRU 001627116 6/17/08 AP temp power cert attached as well as GEC resistance test E251 04 6/24/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001631076 6/24/08 AP WILL BE AN ELECTRICAL IN WALL AND A METAL STUD FRAMING FOR THE FIRST FLOOR. inwall downstairs section A E251 05 7/03/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001636174 7/03/08 AP ELE UP IN AREA C area c metal stud in wall rough in E257 04 7/29/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001650647 7/29/08 AP AREA C ABOVE CEILING E251 06 8/01/08 BS C*ELEC ROUGH IN TIME: 17:00 VRU 001654268 8/04/08 AP CONTROL ROOM AND BATHROON INSPECTION T/S: 07/31/2008 03:58 PM DJOHNSON controll room for max security E257 05 8/05/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001655851 8/05/08 AP WILL BE AN ELECTRICAL ABOVE CEILING ROUGH IN THE KITCHEN. E251 07 10/21/08 BS C*ELEC ROUGH IN TIME: 17:00. VRU 001695188 10/21/08 DA WILL BE FOR ALL THE ELECTRICAL PANELS IN THE BUILDING. 1 Switch breakers in panel dpl. 2. HLS1B- change trans primary to #1 CU 3. LS1B- Change 3 pole breaker to 2 pole E257 06 12/17/08 TI C*ELEC OVERHEAD TIME: 17:00 VRU 001717982 CONTINUED ONTO NEXT PAGE PREPARED 12/16/08, 16:18:11 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 12/17/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ~+r MILTON IS REQUESTING AN ELECTRICAL ABOVE CEILING IN AREA C T/S: 12/16/2008 04:17 PM DJOHNSON - CONTINUED ONTO NEXT PAGE PREPARED 12/18/08, 14:05:11 INSPECTION TICKET PAGE 7 Harnett County INSPECTOR: IVR DATE 12/19/08 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS T/S: 12/16/2008 04:17 PM DJOHNSON not ready E257 07 12/19/08 T~I~ C*ELEC OVERHEAD TIME: 17:00 VRU 001719400 -O nFj_L WILL BE THE ABOVE CEILING ELECTRICAL IN AREA "C". - - COMMENTS AND NOTES PREPARED 1/05/09, 13:59:58 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 1/06/09 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - T/S: 12/16/2008 04:17 PM DJOHNSON not ready E257 07 12/19/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001719400 12/19/08 AP WILL BE THE ABOVE CEILING ELECTRICAL IN AREA "C". E265 01 1/06/09 TI C*ELEC FINAL TIME: 17:00 VRU 001722891 / , (o-OQ ik-S tg f.442x~,4t COMMENTS AND NOTES - - PREPARED 1/09/09, 8:13:16 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 1/09/09 ADDRESS . : 55409 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE : PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 12/17/08 DA MILTON IS REQUESTING AN ELECTRICAL ABOVE CEILING IN AREA C T/S: 12/16/2008 04:17 PM DJOHNSON not.ready E257 07 12/19/08 BS C*ELEC OVERHEAD TIME: 17:00 VRU 001719400 12/19/08 AP WILL BE THE ABOVE CEILING ELECTRICAL IN AREA "C". E265 01 1/06/09 BS C*ELEC FINAL TIME: 17:00 VRU 001722891 1/06/09 AP all electrical finalled except under canopy lights at entrys and generator tests E265 02 1/09/09 T^I~ C*ELEC FINAL TIME: 17:00 VRU 001724483 1-I -Q GENERATOR AND EMERGENCY LIGHTING. COMMENTS AND NOTES PREPARED 1/26/09, 15:12:07 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 1/27/09 I I ADDRESS . : 554:09 *UNASSIGNED SUBDIV: COUNTY OF HARNETT CONTRACTOR BORDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS entrys and generator tests E265 02 1/09/09 BS C*ELEC FINAL TIME: 17:00 VRU 001724483 1/13/09 AP GENERATOR AND EMERGENCY LIGHTING. Generator transfered properly, all emergency lighting was uninterupted. E265 03 1/27/09 C*ELEC FINAL TIME: 17:00 VRU 001729003 COMMENTS AND NOTES - Page 1 of 1 Lynwood Mcdonald From: Tony Wilder Sent: Wednesday, January 28, 2009 9:30 AM To: Lynwood Mcdonald Cc: Gary McNeill; 'Tom Bordeaux'; Tim McNeill - outside; Dan B. Andrews - outside; Gary House - outside; Jim Burgin - outside; 'Scott Sauer; Larry Rollins Subject: Detention Center Lynwood, Per our discussion, I understand the building is ready to be finaled for the Certificate of Occupancy. I also understand the situation with the external efface not being received by Bordeaux Construction due to Bordeaux refusing to accept a flawed product. It is my understanding that the efface is not a functional product but is for aesthetics only. It is also my understanding that the final product should be received and installed prior to the Sheriff's Department move and occupancy. Therefore, I recommend that the building be approved for a Certificate of Occupancy whenever it is in compliance with all North Carolina Building Codes. This will allow Bordeaux to get the state inspections on the detention area in a timely manner. I also do not want our Sheriffs Department staff to occupy the facility prior to the product being accepted and installed. tw Wm. A. (Tony) Wilder, Interim County Manager County of Harnett P. O. Box 759 Lillington, NC 27546 910-893-7555 910-814-2662 (fax) Harnett COUNTY wn¢,r ra s:=t~.:F strong roots • new growth 1/28/2009 COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF COMPLIANCE This certificate issued pursuant to the requirements of Section 307of the North Carolina Administration ' Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Use Classification: 1-3 condition 4 Det. Cent egonditionalUse Permit No.: Type of Construction: I Building Permd No.: 07-50017124 Owner of Building: Harnett County Electrical Permit No.: 07-50017124 Building Address: 175 Bain Street Insulation Permit No.: 07-50017124 Zoning District: NA Plumbing Permit No.: 07 -50017124 Zoning Permit No.: NA Mach. Permit No.: 07-50017124 Date: 02/02/2009 Envir. C.C. No.: NA Brad Sutton NA Building Official Zoning Official 01111, -Ab .41 Q~S ~ ~ al~ XS. PREPARED 1/30/09, 13:59:53 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 2/02/09 ---------I; - - ADDRESS . : 175 BAIN ST SUBDIV: COUNTY OF HARNETT CONTRACTOR: ZO,RDEAUX CONSTRUCTION CO INC PHONE (919) 220-1141 OWNER JAIL-HARNETT COUNTY OF PHONE PARCEL 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS C169 01 4/16/08 BS C*OVERHEAD ELE MECH, PLB VRU 001595750 4/18/08 CA PLUMBING ONLY. AREA D. cancelled per contractor C165 05 5/22/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001614460 5/22/08 AP dayroom areas in section b C165 06 5/28/08 BS C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001615798 5/28/08 CA IN WALL AND ABOVE CEILING WASTE AND VENT 2ND FLOOR AREA A C153 01 6/05/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001620632 6/05/08 CA WILL BE A METAL STUD FRAMING FOR THE 2ND FLOOR AREA "A". C153 02 6/10/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001622471 6/10/08 AP 2ND FLOOR WALL FRAMING. second floor wall framing C169 02 6/16/08 BS C*OVERHEAD ELE, MECH, PLB VRU 001625714 6/16/08 AP above ceiling ducts in kitchen. C167 02 6/30/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001633999 6/30/06 AP WILL BE FOR THE EXTERIOR WALL INSPECTION FOR THE 1ST FLOOR. WANTS THIS FIRST THING. xxxxxxxxxxxxxxxxxxxxxxxxxxx«xxxxxxx««xxxxx C167 03 7/01/08 BS C*WALL INSPECTION TIME: 17:00 VRU 001634500 7/01/08 DA dispatch not insulated C153 03 7/22/08 BS C*BLDG ROUGH IN TIME: 17:00 VRU 001646512 7/22/08 AP WILL BE IN AREA C. framing over entrance to area c C165 07 7/23/08 TI C*OVERHEAD FOR BUILDING TIME: 17:00 VRU 001647395 7/23/08 CA WANTS A ROUGH IN ABOVE CEILING & WASTE AND VENT. AREA "A" MISC 04 8/19/08 BS COMMERCIAL MISCELLANEOUS TIME: 17:00 VRU 001664317 8/19/08 AP MILTON ASKED FOR A PLUMBING GAS LINE INSPECTION FOR THE WHOLE BUILDING, IN THE MORNING. Entire line from mech room to meter. 60 PSI held for 3 days C169 03 10/16/08 BS C*OVERHEAD ELE, MECH, PLB TIME: 17:00 VRU 001693274 10/16/08 AP C169 04 12/09/08 KS C*OVERHEAD ELE, MECH, PLB TIME: 17:00 VRU 001714484 12/09/08 AP WILL BE AREA "A" FOR THE SECURE CORRIDOR. F854 01 1/14/09 TM FM*FINAL INSPECTION TIME: 17:00 VRU 001728971 1/14/09 AP SIGNED OFF PER TJ-NTART A814 01 1/27/09 TI ADDRESS CONFIRMATION TIME: 17:00 VRU 001728989 1/26/09 AP 175 RAIN ST C179 01 1/27/09 BS C*BLDG FINAL TIME: 17:00 VRU 001728997 1/27/09 CA exterior facade incomplete in some areas. I am awaiting instruction from the county before issueing the CO H822 01 1/30/09 GG ENVIR. HLTH/SANITATION FINAL TIME: 17:00 VRU 001726587 1/14/09 AP Permit not issued per Gale Greene for H/S final. C179 02 2/02/09 C*BLDG FINAL TIME: 17:00 VRU 001730464 c4 bg - COMMENTS AND NOTES - - - - - MW t COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF COMPLIANCE This certificate issued pursuant to the requirements of Section 307of the North Carolina Administration Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: UseClassificatrom 1-3 Condition 4 Dee. Cent egonditionalUse Permit No.: Type of Construction: II B Building Permit NO.: 07-50017124 Owner of Building: Harnett County Electrical Permit No.: 07-50017124 Building Address: 175 Bain Street Insulation Permit No.: 07-50017124 Zoning District: NA Plumbing Permit No.: 07-50017124 Zoning Permit No.: NA Mech. Permit No.: 07-50017124 02/02/2009 Envlr. C.O. No.: NA s~Date: Brad Sutton NA Building Official Zoning Official i3 4 This Certificate of compliance allows partial occupancy Per NC General Statute 153A-363.The area allowed for occupancy shall be the sheriffs offices and the E-911 center. shall make periodic inspections as specified in may be obtained by applying to the Inspection General Statute 153A-364 for counties and Department and supplying the information and data 160A-424 for cities. necessary to determine compliance with the technical codes for the occupancy intended. Where necessary, 306.14 Required Public School Inspections. detailed drawings and inspections may be required. Inspections of schools for fire hazards shall be in When, upon examination and inspection, it is found accordance with General Statute 115C-525(b). that the building conforms to the provisions of the technical codes and other applicable laws and ordinances for such occupancy, a Certificate of 307 CERTIFICATE OF COMPLIANCE Occupancy shall be issued. The Certificate of Occupancy shall state the occupancy which may be 307.1 Building Occupancy. A new building shall not safely occupied. be occupied or a change made in the occupancy, nature or use of a building or part of a building until after the 308 SERVICE UTILITIES Inspection Department has issued a Certificate of Compliance. The Certificate of Compliance shall not 308.1 Connection of Service Utilities. No person be issued until all required service systems have been shall make connections from a utility, source of energy, inspected for compliance with the technical codes and fuel or power to any building or system which is other applicable laws and ordinances and released by regulated by the technical codes until approved by the the Inspection Department (General Statutes 153A-363 Inspection Department and a Certificate of Compliance and 160A-423). is issued (General Statute 143-143.2). 307.2 Certificate of Compliance. Upon satisfactory 308.2 Authority to Disconnect Service Utilities. The completion of a building, plumbing, mechanical, Inspection Department shall have the authority to electrical, fire protection or gas system, or portion require disconnecting a utility service to the thereof, a Certificate of Compliance shall be issued. building, structure or system regulated by the The Certificate of Compliance represents that a technical codes, in case of emergency or where structure or system is complete and for certain types necessary to eliminate an imminent hazard to life or of permits is permission granted for connection to a property. The Inspection Department shall have the utility system. The Certificate of Compliance shall not authority to disconnect a utility service when a be construed to grant authority to occupy a building building has been illegally occupied and entry into (General Statutes 153A-363 and 160A423). the building for purposes of making inspections cannot be readily granted. The Inspection Department 307.3 Temporary/Partial Occupancy. A shall notify the serving utility, and whenever possible temporary/partial Certificate of Compliance may be the owner and/or occupant of the building, structure issued permitting occupancy for a stated period for or service system of the decision to disconnect prior specific portions of a building or service system that to taking such action. If not notified prior to the inspector finds may safely be occupied prior to disconnecting, the owner or occupant shall be final completion of the entire building or system notified in writing within eight (8) working hours (General Statutes 153A-363 and 160A-423). (General Statutes 143-143.2, 153A-365, 153A-366, 16OA-425 and 160A-426). 301.4 Issuing Certificate of Occupancy. Upon satisfactory completion of a building and after the 308.3 Temporary Connection. The Inspection final inspection, the Inspection Department may Department may authorize the temporary connection issue a Certificate of Occupancy. The Certificate of of the building or system to the utility source of Occupancy shall state the occupancy which may be energy, fuel or power for the purpose of testing safely occupied. building service systems (General Statutes 153A-363 and 160A-423). 307.5 Existing Building Certificate of Occupancy. A Certificate of Occupancy for any existing building ® 11 NC Administration & Enforcement PREPARED 3/24/09, 15:40:40 INSPECTION TICKET PAGE 1 'Harnett County INSPECTOR: IVR DATE 3/25/09 ADDRESS . : 175 BAIN ST SUBDIV: COUNTY OF HARNETT CONTRACTOR : BORDEAUX CONSTRUCTION CO INC PHONE : (919) 220-1141 OWNER : JAIL-HARNETT COUNTY OF PHONE : PARCEL : 11-0650- - -0008- -01- APPL NUMBER: 07-50017124 CP NEW COMMERCIAL BLDG/ENTERPRISE - - - DIRECTIONS : ADJACENT TO EXISTING COURTHOUSE JB STRUCTURE: 000 000 JAIL/DETENTION & .LAW ENFORCEMENT CENTER FLOOD ZONE . . . . : FLOOD ZONE X PROPOSED USE . . . . . . . : JAIL SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPEC 01 CP ELECTRICAL COMMERCIAL- REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - E265 01 3/25/09 T C*ELEC FINAL TIME: 17:00 VRU 001747500 NEW METAL POLE BURIED IN BACK LEFT CORNER OF PROPERTY. CONTACT PERSON - DALE COSBINN CELL 919 77633-2434 COMMENTS AND NOTES -v-`°i<~Cr'd- a g € COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this stricture was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: Use Classification: 1-3 cond. a Detention Cent eUronditlonalUsePermit No.: NA Type of Construction: II $ Building Permd No.: 07-50017124 Owner of Building: Harnett County Electrical Permit No.: 07-50017124 Building Address: 175 Bain St Insulation Permit No.: 07-50017124 Zoning District: NA PlumbingPerrnitNo.: 07-50017124 Zoning Permit No.: NA Mech. Permit No.: 07-s0o17124 i EnVir. C.O. No.: NA Date: 0412B/09 Brad Sutton NA Building Official Zoning Official Y M M Y } I r i I ®SELEYARCH ITECTS A P R O F E S S I O N A L C O R P O R A T I O N CHARLOTTE April 27, 2009 HARRISONBURG 1 RALEIGH-DURHAM Harnett County I RICHMOND 102 East Front Street VIRGINIA BEACH Lillington, NC 27548 WARRENTON i Re: Harnett County Jail and Detention Center 1 Mr. Wilder, It is the position of Moseley Architects and our engineers that the Harnett County Jail and 1 Detention Center was designed to meet the intent of the North Carolina building code. We believe that the issues raised by NCDHHS have been addressed either via additional work added to the project or that the item is not a requirement of the building code. I have again attached the original comments from NCDHSR and below we have provided the status of the issues. 1. Fan shut down time. Addressed by Moseley letter on March 17, 2009 - Accepted by NCDHHS 2. Smoke detectors in Janitors closets and Storage rooms. Addressed by Moseley letter on March 17, 2009 - Accepted by NCDHHS 3. Reprogramming of FACP silence control. Issue handled in the field - Accepted by NCDHHS 4. Visual alarm in Dry storage room. Work installed - Accepted by NCDHHS 5. Smoke control. We have designed the facility with 2 smoke compartments that meet 1 the NC building code requirement for smoke control. This issue was also discussed during a meeting on April 22, 2009 with NCDHHS It is understood that the county would still like to add some lighting in the cells to the emergency circuits. We have the pricing from the contractor and can break it out separately from the issue with the smoke control. It is our position that the smoke control issue can stand as designed in the original documents. We have also attached a letter from our Engineer for this project that also summarizes the fact that the project was designed to the intent of the INC building code. i As always, if you have any questions please feel free to contact us with any questions. I Sincerely i f f Daniel R. Mace, AIA Vice President Cc: Major McNeill, Harnett County Sheriffs Office Enct: attachments 11430 NORTH COMMUNITY HOUSE ROAD SUITE 225 CHARLOTTE, NO 28277 704,540.3755 704.540 3754 MOSELEYARCH ITECTS,COM j i I Cnrlr. R. s,n..ys. t•.K Consultant Engineering Service, Inc. Phone (336) 724-0139 81 1 West 501 St.. Suite 101 Wmston,Salem. N,C. 27101-2551 Fax 13361724-1812 i E-mail: ces(iD eseng.net i 3 April 27, 2009 Mr. James Stockwell Moseley Architects 1405 Ballantyne Corp Place Charlotte, NC 28277 I Re: Harnett County Jail and Detention Center Lillington, NC i Dear Mr. Stockwell i The plumbing, mechanical, electrical, and fire protection systems were designed in accordance with the applicable codes. The project was submitted to the appropriate State agencies as well as local authorities for their review and comments. The final drawings and specifications were approved and released for construction. During construction, the local authorities spent a lot of time at the site reviewing and inspecting the workmanship. The facility was approved by the local authorities. i It was also reviewed by the DHSR Construction Division. All of their comments and concerns have been addressed and discussed with the local authorities. We understand that the local authorities have the ability to accept the facility and move in at any time they choose. The finished product is an excellent facility that the County can utilize and occupy for many years. Please let us know if we may be of further assistance. Sincerely, I Chris R. Stroupe, PE o`'tN Cqp "ay aT ° North Carolina Department of Health and Human Services Division of Health Service Regulation Construction Section 2705 Mail Service Center Raleigh, North Carolina 27699-2705 Beverly Eaves Perdue, Governor William L. Warren, Chief { Lanier M. Cansler, Secretary Phone: 919-855-3893 Jeff Horton, Acting Director Fax: 919-733-6592 t { March 4, 2009 i Mr. Neil Emory, County Manager P.O. Box 759 Lillington, NC 27546 i RE: Project No. J-174-MM/RG Project Title: Harnett County Jail & Detention Center ! New Jail with Capacity of 300 beds Lillington (Harnett County) Dear Mr. Emory On February 20, 2009 Medhat Metry (Architect) and I conducted the Final Inspection for your referenced facility. Listed below are the items that we discovered coupled with the State Building Code and/or the j NC Administration Code for Jails that defines compliance requirements. A written response addressing these items is required. ! 1. The air handler supply and return fans shutdown effectively five to six seconds after the initiation of the visual and audible fire alarms. It is the standard and accepted practice that the AHU fans will ! automatically immediately shut down upon activation of a smoke detector providing area coverage. I The codes and regulations that support this standard include the North Carolina State Building Code, Section 909.17 and North Carolina State Mechanical Code, Section 606.4. Section 909.17 defines the time response of this sequence as immediate once the smoke control alarm initiation device activates the alarm. Section 606.4 describes the logistics of this sequence. It is standard practice that the more stringent code applies. 2. My recommendation to install smoke detectors in all janitor closets and storage rooms is based on the fact that fires and toxic fumes are caused by the various stored materials interaction with each other. The intent here is early detection noting that a sprinkler head will not activate until you have a fire. Please note this-is a recommendation and not a-requirement 3. The reprogramming of the FACP silence control is accepted. The silence mode will shut off audible alarms while allowing the visual alarms to remain active. Location: 701 Barbour Drive. Dorothea Dix Hospital Campus, Raleigh, N.C. 27603 - An. Equal Opportunity I Affirmative Action Employer i i' Harnett Co. Jail & Detention Center-New 300 Bed Capacity March 5, 2009 J-174-MM/RG Page 2 of 2 4. The requirement for a visual alarm in the dry storage room is based on its function as a work space that will be both sound and visually isolated from the adjacent area. In addition the size of the room is I greater than 400 sq. ft. and according to NFPA 72, National Fire Alarm Code, Section 7.5.4.3/Table 7.5.4.3.1(a) a room this size requires one visual alarm as a minimum. The occupants of this room will not easily hear the alarms outside the door but it should sound greater than l Odbs. 5. The emergency power requirement for the electrical system is addressed in the NC Administrative Code, Section Electrical Systems 14J .1219(a) and (f). It (t) reads that each jail shall have an auxiliary emergency power supply for each electrical system. Upon inspection it was discovered that you have limited emergency power in the Sally Port, Booking Area, Medical Suite and OfficeNisitation areas. The environmental equipment was without power and no evidence of required lighting levels and engineered smoke evacuation in holding cells. Please provide written explanation addressing how you will maintain inmate processing operations and keep environmental and life safety systems on line in noted areas during the times when a power outage exist for extended time periods. The NC Administration Code Subchapter 147 denotes the basic requirements as follows: • Rule 14J .1001 requires access to medical services day to day. • Rule 14J .1217(a) requires the ambient temperature to be maintained at 68°F (min.) during heating season and 85°F during cooling season. • Rule 14J.1217(b) requires that you provide 10 CFM of fresh/outside air for each inmate. • Rule 14J .1219(a) requires provision of 30 foot-candles of artificial lighting in each confinement unit. • Rule 14J. 1219(t) each jail shall provide auxiliary power for each electrical system. • NC State Building Code, Section 408.8 windowless buildings shall be provided with an smoke control system. I I . Should you have any questions or if we can be of further service, please let us know. ! Respectfully, Ronald W. Gales I Building Systems Engineer Construction Section E-mail: Ronald. Galesgncmail.net Rwg cc: Brad Sutton, Code Enforcement Officer III Moseley Architects T.J. McLamb, Chief Deputy Fire Marshall - Harnett Co.