Loading...
IPACHTE# 0 9- Harnett County Department of Public Health 2 5 2 g 7 Improvement Permit A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: ~ 52 J / 7 g 141 'rj~ mod . ISSUED TO c~c o ~ ✓,f att SUBDIVISION 14 i - VU 'L LOT # NEW V REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: a 81CS-.t, Proposed Wastewater System Type: ov~tfe.~ e~ Q Projected Daily Flow: V Q. GPD Number of bedrooms: 13 Number of Occupants: ` max Basement ❑Yes Pump Required: ❑Yes [R o~ ❑ Ma be required based on final location and elevations of facilities Type of Water Supply: ❑ Community f? Public ❑ Well Distance from well feet Permit valid for: E~<ive years Permit conditions: ❑ No expiration Authorized State Agent:: Date: 7 Z-aQ SEE ATTACHED SITE SKETCH The issuance of this permit by t ealth Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, pla( or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the laws and Rules for Sewage Treatment and Disposal and to conditions of this permit. Construction Authorization (Required for Building Permit The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: Cw c)c ~c. ✓ S~ to PROPERTY LOCATION: SUBDIVISION _-I ; yc LOT # Facility Type: zp Ct L1 New ❑ Expansion ❑ Repair Basement? ❑ Yes ❑ No Basement Fixtures? ❑ Yes ❑ No Type of Wastewater System** C a tf e.~, (Initial) Wastewater Flow: JG 0 GIRD (See note below, if applicable Ca t , e c. `.-Q (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size 016b 0 gallons Exact length of each trench J-0 feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of. 02 0 inches (Trench bottoms shall be level to +/-1/4" in all directions) Pump Requirements: ft. TDH vs. GPM Conditions: Trench Spacing: Feet on Center Soil Cover: inches (Maximum soil cover shall not exceed 36" above the trench bottom) inches below pipe Aggregate Depth: a inches above pipe inches total *If applicable / undeatand the system type specified is different /ram the type specified on the application. / accept the tpecirlwiont of this permit Owner/Legal Representative Signature: Date: This Construction Authorization is subiect to reva"bon if thr cite nlan nlat nr rho int-AnA II« A-- Tha a.. _ ,.u~~. u,~,u a vlall~[ III vn-J IF VI t1I, IIII) construction Authonzabon is subject to com I e with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit. SEE ATTACHED SITE SKETCH Authorized State Agen . Date: -2 CC- Construction Authorization Expirati 2Z on Date: HTE# 09-5- -2233? Permit # IF?. narnett County Department of Public nealth Site Sketch f PROPERTY LO(ATON: .5-4 6 9 /"1 c w4-.~ e e. ISSUED T0: 1 do ~o. 'w fcrc~ SUBDIVISION LOT # c3~e~r Authorized State Agent: Date: 7 Z° 05 ~gf 1 3 as 11 dy' - t I 1 'JA Ac~~sr/~l.'~C7 ~ c,c Department of Environment, Health, and Natural Resources F. Division of Environmental Health On-site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Address: Proposed Facility: Location of Site: Water Supply: Evaluation Method: Type of Wastewater: Design Flow (.1949): [ Public [ ] Individual [ ~Auger Boring [ wage Sheet: Property ID:~ Lot File Code: Applicant: [ 1 Well [ ] Pit [ ] Industrial Process Date Evaluated: 7 Property Size: l Property Recorded: [ j Spring [ J Other [ ] Cut [ ] Mixed P R O F SOIL MORPHOLOGY 1941 OTHER PROFILE FACTORS 1 L E # .1940 Landscape Positionl Slope% Horizon Depth (IN.) .1941 Structure/ Texture .1941 Consistence Mineralogy .1942 Soil Wetness/ Colnr 1943 Soil Depth (fN.) .1956 Sapro Class .1944 Restr Horiz Profile Class & LTAR C' Is G- /L Description Initial System Repair System Available Space (.1945) System Type(s) C r ✓ Site LTAR Other Factors (.1946): Site Classification (.1948): .S_ Evaluated By: Others Present: