INSPECTIONS PREPARED 11/02/07,.14:03:07 INSPECTION TICKET PAGE 47 Harnett County INSPECTOR: IVR DATE 11/05/07 ADDRESS 55912 *UNASSIGNED SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER ; LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 301n to 421w rt 1/2mile house on rt.jd STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SEE) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 I I-nom i~6 COMMENTS AND NOTES L~ aub pi. D1 e- _7"o '2 Paz/ o < ARED 11/06/07, 14:03:17 INSPECTION TICKET PAGE 50 fdareft'z'unty INSPECTOR: IVR DATE 11/07/07 ADDRESS 55912 *UNASSIGNED SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR IN & CLUB RD ON RT.JD STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION . TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 TI R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 COMMENTS AND NOTES Harnett County Inspection Department 102 East Front St P.O. Box 65 Lillington, NC 27546 Phone (910) 893-4876 Fax (910) 893-2798 STOP WORK ORDER Plans have been re-drawn from what was approved during plan review. Piers and foundation walls have been moved. Resubmit new professionally drawn foundation and floor plan with engineered trusses to match current configuration of home. Do not pour footing until this has been corrected. Code Enforcement Official Signature _Ken Slattum 110707 PREPARED 11/13/07, 14:21:45 INSPECTION TICKET PAGE 58 Harnett County INSPECTOR: IVR DATE 11/14/07 - - - - ADDRESS . : 55912 *UNASSIGNED SUBDIV: CONTRACTOR : MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER : LAWSON THYRON S & SHIRL PHONE : PARCEL : 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514676 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. 8101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 T,j /1 R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 COMMENTS AND NOTES - - - 11 PREPARED 11/19/07, 15:33:56 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 11/20/07 ADDRESS . : 55912 *UNASSIGNED SUBDIV: CONTRACTOR : MOORE DONALD EDWARD SR PHONE (910) 964-5405 OWNER : LAWSON THYRON S & SHIRL PHONE - -1 PARCEL : 11-0660- - - 0029- APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) - - - - DIRECTIONS : 42iS/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD - STRUCTURE: 000 000 63X57 3BR, SCREEN''PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPSF 00 CP • SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG F00TING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 TI R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 1~-1-0 V Q~ scheduled per ken. COMMENTS AND NOTES - - PREPARED 12/19/07, 14:04:32 INSPECTION TICKET PAGE 30 ':Harnett County INSPECTOR: IVR DATE 12/20/07 ADDRESS . : 55912 *UNASSIGNED SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHTRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. 3101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 B103 01 12/20/07 TI R*BLDG FOUND & TEMP SVC POLE VRU 001538354 1 Z-2d ile COMMENTS AND NOTES PREPARED 12/27/07, 8:05:36 INSPECTION TICKET PAGE 1 Harfe~Ca;uounty INSPECTOR: IVR DATE 12/27/07 ADDRESS . : 55912 *UNASSIGNED SUBDIV: CONTRACTOR : MOORE DONALD EDWARD SR PHONE (910) 964-5405 OWNER : LAWSON THYRON S & SHIRL PHONE PARCEL : 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11120107 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 TI R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 COMMENTS AND NOTES Violation Notice ®o Not Remove Harnett County Inspection ®eparbnent 102 East Front St P.O. Box 6S iillington, NC 27646 Phone (910) 893-4876 Fax (910) 893-2793 07-50018665 1. Panel cover still missing. When you open the external cover, you have open bus bars. 2. Need to damp proof foundation from finish grade to footer. 3. $50.00 re-inspection fee. Code Enforcement Official Signature _Ken Slattum_910-984-4766 PREPARED 1/07/08, 14:01:26 INSPECTION TICKET PAGE 33 Harnett County- INSPECTOR: IVR DATE 1/08/08 ADDRESS 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHIRL PHONE : - PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 421S/E CORNELIUS BLVD BETWEEN NEIGHBOR IN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. 3101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug foster not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have o(rpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 R*OPEN FLOOR VRU 001543925 1-,y E209 01 i/0$/08 T7r R*ELEC TEMP POWER CERT VRU 001543941 COMMENTS AND NOTES PREPARED 1/09/08, 14:01:49 INSPECTION TICKET PAGE 26 Harnett County INSPECTOR: IVR DATE 1/10/08 ADDRESS 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 421S/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have o¢pebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. B105 02 1/10/08 TI R*OPEN FLOOR VRU 001544659 k` 1D COMMENTS AND NOTES PREPARED- 3/12/08, 14:03:05 INSPECTION TICKET PACE 15 Harriett County INSPECTOR: IVR DATE 3/13/08 . ADDRESS s•1940 B CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR : MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER : LAWSON THYRON S & SHIRE PHONE : PARCEL : 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 421S/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee 3101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled'prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have o(rpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. B105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 ' _ FOUR TRADE ROUGH IN >2500 VRU 001575950 COMMENTS AND NOTES PREPARED 3/25/08, 14:00:51' INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 3/26/08 ADDRESS 1940 E CORNELIUS' HARNETT BLVD SUBDIV: CONTRACTOR : MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER : LAWSON THYRON S & SHIRL PHONE : PARCEL : 11-0660- - -0029- - -1 APPL NUMBER: 07-5001.8665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 421S/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. P,101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 - TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS. R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have oTpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. - B105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" OC both sides of joint Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Install whirlpool tub and test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. No midstory guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 T~I~~?~ FOUR TRADE ROUGH IN >2500 VRU 001582899 ~.~(.d SY `J customer would like inspection in the afternoon PREPARED 4/01-/08, 14:00:58 INSPECTION TICKET PAGE 16 Harnett Wunty'i INSPECTOR: IVR DATE 4/02/08 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR :IMOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER. :'`AWSON THYRON S & SHIRL PHONE : PARCEL : 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427 03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427 04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001586163 4/01/08 CA R427 05 4/'02/08 TI? FOUR TRADE ROUGH IN >2500 VRU 001586510 COMMENTS AND NOTES j otw,.j PREPARED. 4/01/08, 14:00:58 INSPECTION TICKET PAGE 15 Harnett.J.oun~ty+ INSPECTOR: IVR DATE 4/02/08 ~ADDRESSv 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER :tiLAWSON "THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have oTpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. B105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 BE FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" OC both sides of joint. 3. Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Install whirlpool tub and test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. 7. No midstory CONTINUED ONTO NEXT PAGE r Violation Notice ®o Not Remove Harnett County Inspection Department 102 East Front St P.O. Box 65 Lillington, NC 27546 Phone (910) 8934876 Fax (910) 893-2793 07-50018665 1. Hurricane ties not installed on girder truss. Violations must be corrected for re-inspection or scheduled inspection should be cancelled. 2. Brick veneer on front of house at porch cannot be supported by wood nailed into foundation. Need engineer repair to support brick veneer. $50 re-inspection fee. Code Enforcement Official Signature _Ken Slattum_910-984-4766 PREPARE)° 4/03/08, 11:31:29 INSPECTION TICKET PAGE 2 Harnett o6nty INSPECTOR: IVR DATE 4/03/08 V ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427 03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427 04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001586163 4/01/08 CA R427 05 4/02/08 KS FOUR TRADE ROUGH IN >2500 VRU 001586510 4/02/08 DP 1. Hurricane tiees not installed. 2. Cannot support brick veneer on untreated wood. Need engineers repair. R427 06 FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001588334 COMMENTS AND NOTES PREPARELF 4/03/08, 11:31:29 INSPECTION TICKET PAGE 1 Harnett kounty INSPECTOR: IVR DATE 4/03/08 - ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11107107 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11120107 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12120107 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12120107 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have o4pebn bus bars when you open the external cover. $50 re-inspection fee. 8105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R**ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. 8105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 BS FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" OC both sides of joint. 3. Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Install whirlpool tub and test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. 7. No midstory guides on plumbing. B. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 BS FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. CONTINUED ONTO NEXT PAGE PREPARED 4/04/08, 14:01:17 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 4/07/08 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR : MOORE DONALD EDWARD SR PHONE : (910) 964-5405 OWNER LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 BS FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427 03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427 04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001586163 4/01/08 CA R427 05 4/02/08 KS FOUR TRADE ROUGH IN >2500 VRU 001586510 4/02/08 DP 1. Hurricane tiees not installed. 2. Cannot support brick veneer on untreated wood. Need engineers repair. R427 06 4/03/08 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001588334 4/03/08 AP trusses corrected, no baffles in cathedrals because depth is 13 inches. Front porch veneer was laid on an untreated 2x4. Tear out and build veneer wall from footing, do not pour front porch, call for inspection before pouring 1129 01 4/07 06 TYI R*INSULATION INSPECTION VRU 001588615 COMMENTS AND NOTES PREPARED 12/16/08, 13:59:58 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 12/17/08 ADD ESS` 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONfiACTdZ : SOUTHERN CUSTOM CONSTRUCTION PHONE (910) 892-6913 OWNER. : LAWSON THYRON S k SHIRL PHONE PARCEL . : 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. 7. No midstory guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 BS FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427 03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427 04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001586163 4/01/08 CA R427 05 4/02/08 KS FOUR-TRADE ROUGH IN >2500 VRU 001586510 4/02/08 DP 1. Hurricane tiees not installed. 2. Cannot support brick veneer on untreated wood. Need engineers repair. R427 06 4/03/08 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001588334 4/03/08 AP trusses corrected, no baffles in cathedrals because depth is 13 inches. Front parch veneer was laid on an untreated 2x4. Tear out and build veneer wall from footing, do not pour front porch, call for inspection before pouring 1129 01 4/07/08 KS R*INSULATION INSPECTION VRU 001588615 4/07/08 AP R431 01 12/17/08 TI FOUR TRADE FINAL >2500 VRU 001717735 12/16/08 CA M305 01 12/17/08 R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001717768 ~1- P- P307 01 12/17/08 I~ Q R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001717784 1 1. - 1 ~ !R"T0 <S - - COMMENTS AND NOTES - - PREPARED 12/16/08, 13:59:58 INSPECTION TICKET PAGE 5 Harnett County INSPECTOR: IVR DATE 12/17/08 ADDRESS : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CON&ACT&A SOUTHERN CUSTOM CONSTRUCTION PHONE : (910) 892-8913 OWNER LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have oCpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. 8105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 BS FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" OC both sides of joint. 3. Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Install whirlpool tub and CONTINUED ONTO NEXT PAGE PRE~AREA' 1/08/09, 14:21-:51 INSPECTION TICKET PAGE 3 Harnett 'County INSPECTOR: IVR DATE 1/09/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTORi S(?9iTHERN CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER LAWSON THYRON S & SHIRL PHONE PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 421S/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPSF 00,CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS -101 01 11/05/07 KS R-BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814 01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP V1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have oCpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. B105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 BS FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" OC both sides of joint. 3. Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Insta whirlpool ub and CONTINUED ONTO NEXT PAGE -s--"'-:2 PREP,ARED y 1/08/09, 14:21:51 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 1/09/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTORP: SOWHERN CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER LAWSON THYRON S & SHIRL PHONE PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. 7. No midstory guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 BS FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427 03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427 04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001586163 4/01/08 CA R427 05 4/02/08 KS FOUR TRADE ROUGH IN >2500 VRU 001586510 4/02/08 DP 1. Hurricane tiees not installed. 2. Cannot support brick veneer on untreated wood. Need engineers repair. R427 06 4/03/08 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001588334 4/03/08 AP trusses corrected, no baffles in cathedrals because depth is 13 inches. Front porch veneer was laid on an untreated 2x4. Tear out and build veneer wall from footing, do not pour front porch, call for inspection before pouring 1129 01 4/07/08 KS R*INSULATION INSPECTION VRU 001588615 4/07/08 AP R431 01 12/17/08 TI FOUR TRADE FINAL >2500 VRU 001717735 12/16/08 CA M305 01 12/17/08 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001717768 12/17/08 AP P307 01 12/17/08 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001717784 12/17/08 AP R431 02 12/18/08 TI FOUR TRADE FINAL >2500 VRU 001717743 12/17/08 CA CUSTOMER CALLED AND CANCELLED INSP T/S: 12/17/2008 04:12 PM DJOHNSON R431 03 1/09/09 TI FOUR TRADE FINAL >2500 VRU 001724129 0 4 -K S COMMENTS AND NOTES - ~Y i ' Violation Notice Do Not Remove Harnett County Inspection Department 102 East Front St P.O. Box 65 Llllington, NC 27546 Phone (910) 893-7525 Fax (910) 893-2793 07-50018665 Jan 9,2009 1. Cannot have untreated hand rails or wood on exterior or in contact with concrete. 2. Need engineer to evaluate the addition on the rear of the house and how to prevent water from entering crawl space beneath rear deck. Also need a design to eliminate water beneath home. 3. Need tempered glass next to rear doors in sun room addition. 4. Need 21 inches in front of toilet in half bath 5. Bath vents not to exterior. 6. Debris in crawl space 7. Condensate drain broken on air handler 8. Electrical panel not labeled. 9. All outlets in bedroom shall be on Arc Fault receptacles 10. Need repair for brick veneer at front porch. Written up at rougb-in because it was supported on untreated wood and not carried to foundation or on lintel. 11. Caulk all windows and doors to brick veneer. 12. Washing machine standpipe shall be no lower than 34 inchs off finished floor. Signature _Ken Slattum_910-984-4766 PRPPARSN 2/23/09, 14:00:26 INSPECTION TICKET PAGE 2 Harnett County INSPECTOR: IVR DATE 2/24/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR :i.SOUTHERN CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER LAWSON THYRON S & SHIRL PHONE PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.JD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 8101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07 KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A814.01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07 AP 940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have o4pebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/06 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. B105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 BS FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" OC both sides of joint. 3. Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Install whirlpool tub and - - CONTINUED ONTO NEXT PAGE - - PREPARED: 2/23/09, 14:00:26 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 2/24/09 ADDRESS 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR :-SOUTHERN, CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER LAWSON THYRON S F. SHIRL PHONE PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. 7. No midstory guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 BS FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. - 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427.03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427.04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001586163 4/01/08 CA R427 05 4/02/08 KS FOUR TRADE ROUGH IN >2500 VRU 001586510 4/02/08 DP 1. Hurricane tiees not installed. 2. Cannot support brick veneer on untreated wood. Need engineers repair. R427 06 4/03/08 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001588334 4/03/08 AP trusses corrected, no baffles in cathedrals because depth is 13 inches. Front porch veneer was laid on an untreated 2x4. Tear out and build veneer wall from footing, do not pour front porch, call for inspection before pouring 1129 01 4/07/08 KS R*INSULATION INSPECTION VRU 001588615 4/07/08 AP R431 01 12/17/08 TI FOUR TRADE FINAL >2500 VRU 001717735 12/16/08 CA M305 01 12/17/08 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001717768 12/17/08 AP P307 01 12/17/08 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001717784 12/17/OB AP R431 02 12/18/08 TI FOUR TRADE FINAL >2500 VRU 001717743 12/17/08 CA CUSTOMER CALLED AND CANCELLED INSP T/S: 12/17/2008 04:12 PM DJOHNSON R431 03 1/09/09 FOUR TRADE FINAL >2500 VRU 001724129 1/09/09 !DA 1. Need proper handrails. 2. Need engineer to evaluate the addition that was built without inspections and to determine a method to eliminate water beneath home where "S dumped by roof onto rear deck. 3. Need tempered glass p next to rear doors. 4. Need 21 inches in front of toile in half bath. 5. Bath vents not to exterior. 6. Debris in J crawl space. 7. Condensate drain broken. 8. Electrical r panel not labeled nor are bedrooms smokes and lights on arc DD~( fault. 9.LNeed repair for front porch brick veneer. e, 10.Caulkall window and doors. ✓Washing machine standpipe shall be 34 inches from finished floor. CONTINUED ONTO NEXT PAGE - PR~PARED. 2/23/09, 14:00:26 INSPECTION TICKET PAGE 4 Harnett County INSPECTOR: IVR DATE 2/24/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR :-SOUTHERN CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER LAWSON THYRON S & SHIRL PHONE PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R431 04 2/24/09 TI FOUR TRADE FINAL >2500 VRU 001737477 - COMMENTS AND NOTES - - - FEB-23-2009 15:12 From: 70:9100923652 P.1 n p~ ' n n o i 1 €e in LI bb E N H 1Yi T. 7 ! n MW e m • M ~tl '5 ~ I a M N .yr 1 ~ ''l ~ • nl •4 • y N 1+ m ;v ~ O° O I'n T. fn In N r (a u, a Ij 00 o „ n x Ell, !U v ' ~ ..I zxOr • ` r• yd ~ZO~d PI i; GI T ~ p ~1 6 t )i Nlj rW/. N k N n, ni L In N v ~Ir C. :5 C, 0 ti m rn 7 11 I9 2 U ti ~ 1 N 1. IZ M !p `0 9 n y to z t ii n Iv r .i, ; of rl v F J• 0,3 3 7' in o u, La N 71 U O ti. Y 1 G t. In t7 r m 3 ~ I DI • • U W C p Ell 14 J r. r.. 4 C, T Q~ G b U ~P IA • i 1 m m Cl C. ~ ll U iS In . vl ~ p. A l i p jP PREPARAp 2/24/09, 14:00:10 INSPECTION TICKET PAGE 8 Harnett County INSPECTOR: IVR DATE 2/25/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR SOUTHERN CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER . , i"LAWSON THYRON S & SHIRL PHONE PARCEL . . 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) DIRECTIONS : 4215/E CORNELIUS BLVD BETWEEN NEIGHBOR LN & CLUB RD ON RT.,TD PREMISE NUMBER ****56417023****** STRUCTURE: 000 000 63X57 3BR, SCREEN PORCH FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . : 3.00 PROPOSED USE . . . . . . . : SFD SEPTIC - EXISTING? . . . . : SEWER PERMIT: CPSF 00 CP * SFD REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 11/05/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001514876 11/06/07 DA Cannot perform inspection without plans. Please have plans in box of inspections. B101 02 -11/07/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001517267 11/07/07 DA Footing and plans do not match. Stop work order issued awaiting plans and truss documents. B101 03 11/14/07 KS R*BLDG FOOTING / TEMP SVC POLE VRU 001519602 11/14/07 DP 1. Lug footer not dug per plan and Lynwood/Moore agreement. 2. Temp pole has knockout missing in side. Is this overhead or underground service? Need mast head or conduit for Progress energy. $50 re-inspection fee B101 04 11/20/07. KS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001523299 11/20/07 AP scheduled per ken. A614'01 12/20/07 TI ADDRESS CONFIRMATION VRU 001538347 12/21/07' AP 1940 E CORNELIUS HARNETT BLVD B103 01 12/20/07 KS R*BLDG FOUND & TEMP SVC POLE VRU 001538354 12/20/07 AP backfilled prior to inspection t-pole missing cover E207 01 12/27/07 KS R*ELEC TEMP SERVICE POLE TIME: 17:00 VRU 001539915 12/27/07 DP Cover still missing from panel. You have oCpebn bus bars when you open the external cover. $50 re-inspection fee. B105 01 1/08/08 KS R*OPEN FLOOR VRU 001543925 1/08/08 DA 1. Girder not in center of pier. 2. Floor hanging off in back of garage and to left of front porch. E209 01 1/08/08 KS R*ELEC TEMP POWER CERT VRU 001543941 1/08/08 CA Tpole, not temp power. B105 02 1/10/08 KS R*OPEN FLOOR VRU 001544659 1/10/08 AP R427 01 3/13/08 BS FOUR TRADE ROUGH IN >2500 VRU 001575950 3/13/08 DP 1. Need truss framing layout. Correct truss problems already found. 2. Brace load bearing walls with interior bracing such as metal cross strapping (brick veneer installed prior to rough in inspection) Where vinyl is installed, remove at blocking and nail OSB 6" CC both sides of joint. 3. Install insulation baffles in cathedrals. 4. Install and test fireplace 5. Install whirlpool tub and CONTINUED ONTO NEXT PAGE (12 0'(f IsT, PREPAAD 2/24/09, 14:00:10 INSPECTION TICKET PAGE 9 Harnett County INSPECTOR: IVR DATE 2/25/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR POUTHERN CUSTOM CONSTRUCTION PHONE (910) 892-8913 OWNER : LAWSON THYRON S & SHIRL PHONE PARCEL : 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) - REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - test all plumbing including shower pan. 6. Drain for washer must be 3 inch where horizontal under house. 7. No midstory guides on plumbing. 8. Need to know how plumber is to vent baths. $50 re fee. DO NOT INSULATE..OK TO FINISH SIDING R427 02 3/26/08 BS FOUR TRADE ROUGH IN >2500 VRU 001582899 3/26/08 DA customer would like inspection in the afternoon Midstory guides on plumbing. 2. Baffles in CATHEDRALS. 3. Mark gas line with gas stickers every 5 feet under house. 4.Contact truss company for proper uplift connectors for trusses per truss documents. Correct 2 trusses for bracing as shown on truss plans. DO NOT INSULATE R427 03 3/31/08 KS FOUR TRADE ROUGH IN >2500 VRU 001585173 3/31/08 CA R427 04 4/01/08 TI FOUR TRADE ROUGH IN >2500 VRU 001566163 4/01/08 CA R427 05 4/02/08 KS FOUR TRADE ROUGH IN >2500 VRU 001586510 4/02/08 DP 1. Hurricane tiees not installed. 2. Cannot support brick veneer on untreated wood. Need engineers repair. R427 06 4/03/08 BS FOUR TRADE ROUGH IN >2500 TIME: 17:00 VRU 001588334 4/03/08 AP trusses corrected, no baffles in cathedrals because depth is 13 inches. Front porch veneer was laid on an untreated 2x4. Tear out and build veneer wall from footing, do not pour front porch, call for inspection before pouring 1129 01 4/07/08 KS R*INSULATION INSPECTION VRU 001588615 4/07/08 AP R431 01 12/17/08 TI FOUR TRADE FINAL >2500 VRU 001717735 12/16/08 CA M305 01 12/17/08 KS R*PLUMB SEWER CONNECTION TIME: 17:00 VRU 001717768 12/17/08 AP P307 01 12/17/08 KS R*PLUMB WATER CONNECTION TIME: 17:00 VRU 001717784 12/17/08 AP R431 02 12/18/08 TI FOUR TRADE FINAL >2500 VRU 001717743 12/17/08 CA CUSTOMER CALLED AND CANCELLED INSP T/S: 12/17/2008 04:12 PM DJOHNSON R431 03 1/09/09 KS FOUR TRADE FINAL >2500 VRU 001724129 1/09/09 DA 1. Need proper handrails. 2. Need engineer to evaluate the addition that was built without inspections and to determine a method to eliminate water beneath home where dumped by roof onto rear deck. 3. Need tempered glass next to rear doors. 4. Need 21 inches in front of toile in half bath. 5. Bath vents not to exterior. 6. Debris in crawl space. 7. Condensate drain broken. 8. Electrical panel not labeled nor are bedrooms smokes and lights on arc fault. 9. Need repair for front porch brick veneer. 10.Caulkall window and doors. Washing machine standpipe shall be 34 inches from finished floor. - CONTINUED ONTO NEXT PAGE - PREPARNZ 2/24/09, 14:00:10 INSPECTION TICKET PAGE 10 Harnett County INSPECTOR: IVR DATE 2/25/09 ADDRESS . : 1940 E CORNELIUS HARNETT BLVD SUBDIV: CONTRACTOR _SOUTHERN CUSTOM CONSTRUCTION PHONE : (910) 892-8913 OWNER 'LAWSON THYRON S & SHIRL PHONE : PARCEL 11-0660- - -0029- - -1 APPL NUMBER: 07-50018665 CP NEW RESIDENTIAL (SFD) REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - R431 04 2/24/09 FOUR TRADE FINAL >2500 VRU 001737477 2/24/09 DA Seal line sets at unit. Remove debris in crawl space. Level crawl space and straighten out plastic. R431 05 2/25/09 TI FOUR TRADE FINAL >2500 VRU 001737865 - - COMMENTS AND NOTES a ~ a ' .~a~i~1 Hp '10 '00 n .sit ~t. r p ~~a K(fPo,4 a rq s (I!n rya L" 0 COUNTY OF HARNETT y DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY w ;Porgy This cert if icate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building s, - construction or use. For the following: Use CI_assific ion: PERMIT NUMBERS Owner: Building Permit No.: - fy1 911 Address: Electrical Permit No.. ~j Insulation Permit No.: Plumbing Permit No.: State: Zip Code: Mech. Permit No.:-, to~ s- ~ MFG. Home: Building Official _ cd. V