Loading...
IPACHTE #/2-5-- 362A- Harnett County Department of Public Health Improvement Permit 27233 A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: -SQ S r c? fl-f> ISSUED TO: 6- c, z5!5 27 / SUBDIVISION LOT # NEW ❑ REPAIR ❑ EXPANSION f�7 Site Improvements required prior to Construction Authorization Issuance: Type of Structure: 9—*- S r � Proposed Wastewater System Type: 250h.tZ0&'W a— r`/0 Projected Daily flow: '{l2 GPD Number of bedrooms: Number of Occupants: max Basement []Yes © o O/ Pump Required: []Yes ❑ No L/ Ma be required bid on final location and elevations of facilities Type of Water Supply: ❑ Community Public L�1" Well Distance from well feet Permit conditions: Permit valid for: 2-five years ❑ No expiration Authorized State Agen • d _ Date: l L _ Z b /2 SEE ATTACHED SITE SKETCH The issuance of this permit by th H Ith Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if th ite plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1951, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: Z e4-� PROPERTY LOCATION: /•5^�i? a >Fz«� ;pExpansion IVISION LOT # Facility Type: ❑ New 2;0-j ❑ Repair Basement? ❑ Yes No Basement Fixtures? ❑ Yes Type of Wastewater System' 25p /v 17660&-W�3 -5:%: Win_._ (Initial) Wastewater Flow: `t om GPD (See note below, if applicable ❑) zs-% -tz'-�')CI (Repair) Installation Requirements /Conditions Number of trenches Z Septic Tank Size JD0& gallons Exact length of each trench %5-Z feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of. 26 `)AR inches (Trench bottoms shall be level to +/ -1/4" in all directions) Pump Requirements: ft. TDH vs. GPM Conditions: Trench Spacing: 1 Feet on Center Soil Cover: inches (Maximum soil cover shall not exceed 36" above the trench bottom) inches below pipe Aggregate Depth: L inches above pipe i L inches total WATER LINES (INCLUDING IRRIGATION) MUST BE IOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. * *If applicable: /understand the system type rpeciled is different from the type speciled on the app lication. /accept the pecifications o/ this permit. Owner /Legal Representative Signature: Date: This Construction Authorization is subiect to revocation if the site Dlan. nlat or the intended use chances. The Construction Authorization shall not be transferred when there is a rhanoe in nwnershin of rho vita This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH Authorized State A t: Date: ( 7- 1 2, Construction Authorization Expiration Date: 1 Z -? - 1 -] HTE# 1 Z— — 3a20�, Permit # Z ? Z 3 i Harnett County Department of Public Health Site Sketch PROPERTY LOCATON:I. ISSUED TO: Lark - SUBDIVISION LOT # Authorized State Agent<---)r., Date: /Z° Z Z V / v b ;f } Liss rr-54L-S 12-6 j"M