Loading...
INSPECTIONS PREPARED{ 2/19/07, 14:33:59 INSPECTION TICKET PAGE 7 Harhett C%unty INSPECTOR: IVR DATE 2/20/07 - - ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR CAROLINA CUSTOM BUILDERS PHONE (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - - 0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK I STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . MOD SEPTIC - EXISTING? . . . . : NEW SEWER . . . . . . . . . . UNKNOWN ----I--------------------------------------------- PERMIT: CPBP 01 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/~SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - B103'01 10/12/06 BS R *BLDG FOUND & TEMP SVC POLE VRU 001290402 10/12/06 DA R12501 1/04/07 BS ONE TRADE ROUGH IN VRU 001331016 1/04/07 DA rough in on garage R125 02 2J20/07 I ONE TRADE ROUGH IN VRU 001357243 61.2 a87 _ - CONTINUE ONTO NEXT PAGE - 5ce 1G i PREPAREDi 2/19/07, 14:33:59 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 2/20/07 ----'WI - - - - ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR CAROLINA CUSTOM BUILDERS PHONE (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . MOD SEPTIC - EXISTING? . . . . : NEW SEWER . . . . . . . . . . UNKNOWN PERMIT: CPBP 00 CP BUILDING PERMIT I'i REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - - - - - - B101.1 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001280009 1 9/27/06 AP B103 01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE VRU 001290394 10/12/06 DA B103I02 10/17/06 BS R*BLDG FOUND & TEMP SVC POLE VRU 001293174 10/17/06 DP 3 piers, 2 in ceter row, 3 and 4 from right end and 1 pier in front row 2nd from right not corrected per previous violation. R225 01 1/04/07 BS TWO TRADE ROUGH IN VRU 001331024 1/04/07 DA rough in on up stairs of home ~6 VRU 001357235 R225i 02 2/20/07 TWO~TRADE ROUGH ~TC - CONTINUED ONTO NEXT PAGE - PREPARED 2/19/07,,14:33:59 INSPECTION TICKET PAGE 8 Hartiett County INSPECTOR: IVR DATE 2/20/07 - - - - - ADDRESS 422 CLARKS CORNER RD SU13DIV: CONTRACTOR CAROLINA CUSTOM BUILDERS PHONE (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK - STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . . 4.00 PROPOSED USE . . . . . . . MOD SEPTIC - EXISTING? . . . . : NEW SEWER . . . . . . . . . . UNKNOWN PERMIT: CPMH 00 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ----I-------------- - - 13101!I01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001291004 9/27/06 AP B103I01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001291020 10/12/06 DP 1. Some piers and exterior foundation walls have bed joints that exceed max allowed of 3/4 inch. Use sawn block to level foundation. CANNOT USE MORTAR. Some joints up to 2.5 to 3 inches. 2. All stepdown boards must be removed from foundation. A81401 10/20/06 TI ADDRESS CONFIRMATION VRU 001295518 10/20/06 AP 422 CLARKS CORNER RD LOT B103'02 10/20/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001295526 10/20/06 AP B1191I01 11/14/06 KS R*MOD MARRIAGE WALL VRU 001307529 11/14/06 AP H824I01 11/30/06 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001317338 11/30/06 AP B117'01 1/04/07 BS R*MODULAR ROUGH-IN VRU 001331065 1/04/07 DA no setup info or truss documents at jobsite. 2. Marriage lines covered before inspection (floor load beams for secondfloor loads at marriage line) 3. Rough ins called in but not ready. Tubs not set, fireblocking not done, no insulation baffles, etc. 4. Need truss engineeering for overframe supported on truss system. B117I02 20/07 R*MODULAR ROUGH-IN VRU 001357227 ----I--------------------------- - CONTINUED ONTO NEXT PAGE I PREPARED 2/X9/07,. 14:33:59 INSPECTION TICKET PAGE 10 Haynett county INSPECTOR: IVR DATE 2/20/07 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR CAROLINA CUSTOM BUILDERS PHONE (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 % 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X # BEDROOMS . . . . . . . . 4.00 PROPOSED USE . . . . . . . : MOD SEPTIC - EXISTING? . . . . NEW SEWER . . . . . . . . . . : UNKNOWN - I PERMIT: CPPR 00 CP PLUMBING RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 1/04/07 R125'-01 1/04/07 - BS ONE-TRADE-ROUGH-IN VRU 001331057 DA rough in up stairs no setup info or truss documents at jobsite. 2. Marriage lines covered before inspection (floor load beams for secondfloor loads at marriage line) 3. Rough ins called in but not ready. Tubs not set, fireblocking not done, no insulation baffles, etc. 4. Need truss engineeering for overframe supported on truss system. R12502 2/20/0 TI ONE TRADE ROUGH IN VRU 001357250 a ~ ~~~111 COMMENTS AND NOTES it I I I PREPARED 2/27/07, 14:01:42 INSPECTION TICKET PAGE 6 Harnett County INSPECTOR: IVR DATE 2/28/07 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR : CAROLINA CUSTOM BUILDERS PHONE : (919) 776-2477 OWNER : WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL : OS-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK - 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X I 7 CPIR 00 CP INSULATION RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ---i----------------------- I129 01 2/28/07 I -R*INSULATION INSPECTION VRU 001362045 '~i ,d NSPECTOR TO LOOK AT UPSTAIRS TUB AT INSULATION INSPECTION. COMMENTS AND NOTES I fill ill I i I PREPARED 9/26/06, 14:01:46 INSPECTION TICKET PAGE 24 Harnett County INSPECTOR: IVR DATE 9/27/06 ADDRESS : *UNASSIGNED SUBDIV: CONTRACTOR QUAIL RUN HOMES PHONE : (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL 05-0625- - - 0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X I PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/ISQ COMPLETED RESULT RESULTS/COMMENTS B1011 01 9/27/06 R*BLDG FOOTING / TEMP SVC POLE VRU 001280009 I COMMENTS AND NOTES I it I PREPARED 10/12/06, 8:04:48 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 9/27/06 ADDRESS 422 CLARKS CORNER RD SUBDIV: CONTRACTOR QUAIL RUN HOMES PHONE (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS TAKE 401 TOWARD TO. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK _ STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMH 00 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/I SQ COMPLETED RESULT RESULTS/COMMENTS B101I 01 9/27/06 TI_ R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU k: 001291004 -X714 Ll-C1gR5 COMMENTS AND NOTES i I I PREPARED 10/12/06, 8:06:32 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 10/12/06 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR QUAIL RUN HOMES PHONE : (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIREICTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK III IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAM MODULAR FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/I SQ COMPLETED RESULT RESULTS/COMMENTS B101I 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001280009 9/27/06 AP B103 01 10/12/06 TI / R*BLDG FOUND & TEMP SVC POLE VRU 001290394 ~h PERMIT: CPBP 01 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS _ B103 01 10/12/06 I R*BLDG FOUND & TEMP SVC POLE VRU 001290402 - PERMIT: CPM 00 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/ISQ COMPLETED RESULT RESULTS/COMMENTS B1011 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001291004 9/27/06 AP B103 01 10/12/06 R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001291020 b 'D T~ COMMENTS AND NOTES v Violation Notice Do Not Remove Harnett County Inspection Department 102 East Front St P.O. Box 65 Llllington, NC 27546 Phone (910) 893-4876 Fax (910) 893-2793 App # 06-50015002 Carolina Custom Homes 422 Clarks Corner 1. Some piers and exterior foundation walls have bed joints (between bottom course and footing) that exceed max allowed of 1/4". Sawn block must be used to level the base course. Some joints as much as 2 inches. 2. All stepdown boards must be removed from the foundation. $50.00 reinspection fee. Do not set house Code Enforcement Official Signature 10/12/06 III II PREPARED 10/16/06, 14:00:03 INSPECTION TICKET PAGE 29 Harnett County INSPECTOR: IVR DATE 10/17/06 -r--' 'I ADDRESS 422 CLARKS CORNER RD SUBDIV: CONTRACTOR : QUAIL RUN HOMES PHONE (919) 776-2477 OWNER : WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL : 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T;S: 05/31/2006 10:10 AM JBROCK _ STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101, 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001280009 9/27/06 AP B103I 01 10/12/06 R*BLDG FOUND & TEMP SVC POLE VRU 001290394 10/12/06 DA 2103!02 10/17/06 R*BLDG FOUND & TEMP SVC POLE VRU 001293174 iD• i7•DL COMMENTS AND NOTES it I III i I Violation Notice Do Not Remove Harnett County Inspection Department 102 East Front St P.O. Box 65 I.111ington, NC 27546 Phone (910) 893-4876 Fax (910) 893-2793 App # 06-50015002 Quail Run Homes 422 Clarks Corner 1. Facing front of house center row of piers 3 and 4 from the garage end need to be torn down and re set. Bed joint is too thick. When using cut block to level piers, they must be laid with the open web vertical, not horizontal. Also the front row of piers, second pier from the right needs to be torn down and re set. This was noted on the previous violation. $50.00 reinspection fee applies Code Enforcement Official I Signature I I, PREPARED 10/19/06, 13:59:16 INSPECTION TICKET PAGE 27 Harnett County INSPECTOR: IVR DATE 10/20/06 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR QUAIL RUN HOMES PHONE : (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPMH 00 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101, 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001291004 9/27/06 AP B103 01 10/12/06 R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001291020 10/12/06 DP 1. Some piers and exterior foundation walls have bed joints that exceed max allowed of 3/4 inch. Use sawn block to level foundation. CANNOT USE MORTAR. Some joints up to 2.5 to 3 inches. 2. All stepdown boards must be removed from foundation. A814 01 10/20/06 TI ADDRESS CONFIRMATION VRU 001295518 B103j 02 10/20/06 1 Q! R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001295526 ----~I COMMENTS AND NOTES i PREPARED 11/13/06, 13:59:33 INSPECTION TICKET PAGE 18 Harnett County INSPECTOR: IVR DATE 11/14/06 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR QUAIL RUN HONES PHONE : (919) 776-2477 OWNER : WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL : 05-0625- - - 0100- - - APPLNUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK ----IT----------- STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOCD ZONE . . . . : FLOOD ZONE X PERMIT: CPMH 00 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001291004 9/27/06 AP B103 01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001291020 10/12/06 DP 1. Some piers and exterior foundation walls have bed joints that exceed max allowed of 3/4 inch. Use sawn block to level foundation. CANNOT USE MORTAR. Some joints up to 2.5 to 3 inches. 2. All stepdown boards must be removed from foundation. A814 01 10/20/06 TI ADDRESS CONFIRMATION VRU 001295518 10/20/06 AP 422 CLARKS CORNER RD LOT B103 02 10/20/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001295526 10/20/06 AP B119, 01 1~1/6 T~ Q *MOD MARRIAGE WALL VRU 001307529 I T~1 _IV._~-1~1! s COMMENTS AND NOTES I I II PREPARED 11/20/06, 13:59:59 INSPECTION TICKET PAGE 17 Harnett County INSPECTOR: IVR DATE 11/21/06 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR QUAIL RUN HOMES PHONE (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL.NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME j20DULAR FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPER 00 CP ELECTRICAL RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E207 01 11/21/06 TI R*ELEC TEMP SERVICE POLE VRU k: 001311331 (2A - Ng _ - COMMENTS AND NOTES 'I I~ PREPARED 11/29/06, 14:00:32 INSPECTION TICKET PAGE 20 Harnett County INSPECTOR: IVR DATE 11/30/06 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR QUAIL RUN HOMES PHONE : (919) 776-2477 OWNER WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL~NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE j T/S: 05/31/2006 10:10 AM JBROCK - STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X i PERMIT: CPER 00 CP ELECTRICAL RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS E207' 01 11/21/06 nA R*ELEC TEMP SERVICE POLE VRU 001311331 11/21/06 strap down-pipe seal openings in panel at breakers and not with tape. E207 02 11/30/06_ R*ELEC TEMP SERVICE POLE VRU 001315365 1~FI~--it----~ -fJi~ y COMMENTS AND NOTES it I 11 1 PRErARED .1/03/C7, 13:59:34 INSPECTION TICKET PAGE 13 Harnett County INSPECTOR: IVR DATE 1/04/07 ----s ADDRESS : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR : QUAIL RUN HOMES PHONE (919) 776-2477 OWNER : WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL : 05-0625- - -0100- - - APPLNUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X I--______ PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B101X01 9/27/C6 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001280009 9/27/06 AP B103 1I01 10;12/06 BS R-BLDG FOUND & TEMP SVC POLE VRU 001290394 10/12/06 DA 2103i02 10/17/06 BS R*BLDG FOUND & TEMP SVC POLE VRU 001293174 10/17/06 DP 3 piers, 2 in ceter row, 3 and 4 from right end and 1 pier in front row 2nd from right not corrected per previous violation. R225I01 1/04/07 TWO TRADE ROUGH IN VRU 001331024 rough in on up stairs of home 11 PERMIT: CPBP 01 CP BUILDING PERMIT IRE UESTED IN P DESCRIPTION TYP/SQ CO PLETED RE LT RESULTS/COMMENTS B103I01 10 12/06 BS R *BLDG FOUND & TEMP SVC POLE VRU 001290402 10 12/06 DA R1251I01 1 04/07 TI ONE TRADE ROUGH IN VRU 001331016 rough in on garage PERMIT: CPER 00 CP ELECT ICAL RESIDENTIAL RE UESTED I SP DESCRIPTION TYP/SQ CO PLETED RE ULT RESULTS/COMMENTS -20701 11/21/06 M R*ELEC TEMP SERVICE POLE VRU 001311331 11/21/06 D strap down-pipe seal openings in panel at breakers and not with tape. E2071,02 1 /30/06 S R*ELEC TEMP SERVICE POLE VRU 001315365 1 /30/06 P 8125 ~01 /04/07 I ONE TRADE ROUGH IN VRU 001331032 rough in up stairs PERMIT: C 0 CP M HOME UESTED SP DESCRIPTION TYP/SQ C MPLETED SULT RESULTS/COMMENTS 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001291004 -101 9/27/06 AP B103 01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001291020 10/12/06 DP 1. Some piers and exterior foundation walls have bed joints that exceed max allowed of 3/4 inch. Use sawn block to level foundation. CANNOT USE MORTAR. Some joints up to 2.5 i PREPARED. 1/03/07, 13:59:34 INSPECTION TICKET PAGE 14 Harnett County INSPECTOR: IVR DATE 1/04/07 ADDRESS 422 CLARKS CORNER RD SUBDIV: CONTRACTOR : QUAIL RUN HOMES PHONE (919) 776-2477 OWNER : WHITE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL : 05-0625- - -0100- - - APPLiNUMBER: 06-50015002 CP MODULAR HOME ____J_____________________________ REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS _ to 3 inches. 2. All stepdown boards must be removed from foundation. A814I01 10/20/06 TI ADDRESS CONFIRMATION VRU 001295518 10/20/06 AT 422 CLARKS CORNER RD LOT 8103 02 10/20/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001295526 10/20/06 AP B119101 11/14/06 KS R*MOD MARRIAGE WALL VRU 001307529 11/14/06 AP H824'01 11/30/06 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001317338 11/30/06 AP 8117 101 1/.~~4? T~ - R*MODULAR ROUGH=IN VRU 001331065 -_-____-I______________ PERMIT: CPMR 00 MECHAN CAL RESIDENTIAL REQUEED IN ' DESCRIPTION L °D RESU T RESULTS/COMMENTS TYP/SQ COMP J 01 1/0 /07 TI ONE TRADE ROUGH IN VRU 001331040 rough in up stairs PERMIT: CPPR 0 CP PLUMBIN RESIDENTIAL REQ STED INS DESCRIPTION TYP/SQ "OM ETED RES T RESULTS/COMMENTS R125 ,01 1 01/0 TI ONE TRADE ROUGH IN VRU 001331057 rough in up stairs COMMENTS AND NOTES i I I I I I i DO NOT REMOVE! Harnett County Inspection Department 102 East Front Street • P.O. Box 65 Lillington, NC 27546 nn Phone: (9110) 893-7527 • Fax: (910) 893-2793 Job Name: (X U Q,' I !mot r'L"""'"'' Date: I _q d Address: 4Q. Lot No.: Permit No.: Qln S ' ~-406 (Check Box for Violation) Q Q ❑ ❑ ❑ ❑ ❑ ❑ Footing Foundation Bldg. Elec. Plumb. Mech. Insul. Floor Fram. ❑ ❑ ❑ ❑ ❑ ❑ 0 Floor MFG. Modular Damp/Water Structural Wall Other Slab ~Home ( Proof../ 1 l Sheath. / Violations Found/./yD.yr~rr~ A a ( SO1!1S A ',iAj C'o✓ ~PFUL! f tdDy( 3 nS r'n~~i( iA1. Ira ifn •KPa~tl. T ~5 /J()Se a#'C il(OIt S~t,O~, C)n.P Ct G✓a~~PCr /.la r~yYt~a ' l~ k'a(r i-~'-d'jj v~t~a'~1cZY1hG {ode Enforcement O9"4/ Date: Signature r- It is unlawful for any sub contractor, general contractor, or owner to cover or cause to be covered any part of the work with flooring, sheetrock, earth or other material until the proper inspector had ample time to approve the installation. WHITE COPY - CONTRACTOR/OWNER • YELLOW COPY - INSPECTORS PREPARED 2/08/08, 14:06:07 INSPECTION TICKET PAGE 2 Barnett County INSPECTOR: IVR DATE 2/11/08 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR : PHONE : OWNER i: WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL . : 05-0625- - -0100- - - APPLINUMBER: 06-50015002 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS 11/21/06 DA strap down-pipe seal openings in panel at breakers and not with tape. E207`.02 11/30/06 BS R*ELEC TEMP SERVICE POLE VRU 001315365 11/30/06 AP R125~01 1/04/07 BS ONE TRADE ROUGH IN VRU 001331032 1 1/04/07 DA rough in up stairs no setup info or truss documents at jobsite. 2. Marriage lines covered before inspection (floor load beams for secondfloor loads at marriage line) 3. Rough ins called in but not ready. Tubs not set, fireblocking not done, no insulation baffles, etc. 4. Need truss engineeering for overframe supported on truss system. R131 01 2/11/08 TI ONE TRADE FINAL VRU 001560630 PERMIT: CPMH 00 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/$Q COMPLETED RESULT RESULTS/COMMENTS I____________________________________________________________________________________________ B101 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE TIME: 17:00 VRU 001291004 9/27/06 AP B103 01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001291020 10/12/06 DP 1. Some piers and exterior foundation walls have bed joints that exceed max allowed of 3/4 inch. Use sawn block to level foundation. CANNOT USE MORTAR. Some joints up to 2.5 to 3 inches. 2. All step down boards must be removed from foundation. A814 01 10/20/06 TI ADDRESS CONFIRMATION VRU 001295518 10/20/06 AP 422 CLARKS CORNER RD LOT B103 02 10/20/06 BS R*BLDG FOUND & TEMP SVC POLE TIME: 17:00 VRU 001295526 10/20/06 AP B119 01 11/14/06 KS R*MOD MARRIAGE WALL VRU 001307529 1 11/14/06 AP H824 01 11/30/06 JM ENVIR. OPERATIONS PERMIT TIME: 17:00 VRU 001317338 11/30/06 AP B117 01 1/04/07 BS R*MODULAR ROUGH-IN VRU 001331065 1/04/07 DA no setup info or truss documents at jobsite. 2. Marriage lines covered before inspection (floor load beams for secondfloor loads at marriage line) 3. Rough ins called in but not ready. Tubs not set, fireblocking not done, no insulation baffles, etc. 4. Need truss engineeering for overframe supported on truss system. B111 02 2/20/07 BS R*MODULAR ROUGH-IN VRU 001357227 2/20/07 DA 1.Need truss documents for garage trusses and garage girder truss nailing pattern.2. Cover floor upstairs in bath, set tub, cap tub drain and fill tub with water for drain connection test. 3. Install attic access ladder for unit. OR i TO INSULATE. Recheck all items at insulation inspection R131 01 4111108 Tf„!,_ ONE TRADE FINAL VRU 001560648 PERMIT: CPMR 00 CP MECHANICAL RESIDENTIAL PREPARED 2/08/08, 14:06:07 INSPECTION TICKET PAGE 1 Harnett County INSPECTOR: IVR DATE 2/11/08 ADDRESS . : 422 CLARKS CORNER RD SUBDIV: CONTRACTOR : PHONE : OWNER WHITE JEFFERY & ANGELA PHONE : (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL'NUMBER: 06-50015002 CP MODULAR HOME DIRECTIONS : TAKE 401 TOWARD FU. VAR. LEFT ON CHRISTIAN LIGHT RD LEFT ON COKESBURY RD LEFT ON BALL RD LEFT ON 42 LEFT ON CLARK CORNER GO .4 MILES RIGHT AT FORK IN CURVE T/S: 05/31/2006 10:10 AM JBROCK STRUCTURE: 000 000 40 X 76 4BDR OFF FRAME MODULAR FLOOD ZONE . . . . : FLOOD ZONE X PERMIT: CPBP 00 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/iSQ COMPLETED RESULT RESULTS/COMMENTS B101i 01 9/27/06 BS R*BLDG FOOTING / TEMP SVC POLE VRU 001280009 9/27/06 AP B103 01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE VRU 001290394 10/12/06 DA B103 02 10/17/06 BS R*BLDG FOUND & TEMP SVC POLE VRU 001293174 10/17/06 DP 3 piers, 2 in ceter row, 3 and 4 from right end and 1 pier in front row 2nd from right not corrected per previous violation. x225 01 1/04/07 BS TWO TRADE ROUGH IN VRU 001331024 1/04/07 DA rough in on up stairs of home R225 02 2/20/07 BS TWO TRADE ROUGH IN VRU 001357235 2/20/07 DA 1.Need truss documents for garage trusses and garage girder truss nailing pattern.2. Cover floor upstairs in bath, set tub, cap tub drain and fill tub with water for drain connection test. 3. Install attic access ladder for unit. OK TO INSULATE. Recheck all items at insulation inspection X229 01 2/11/08 TI TWO TRADE FINAL VRU 001560614 - PERMIT: CPBP 01 CP BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP%SQ COMPLETED RESULT RESULTS/COMMENTS B103 01 10/12/06 BS R*BLDG FOUND & TEMP SVC POLE VRU 001290402 10/12/06 DA R125 01 1/04/07 BS ONE TRADE ROUGH IN VRU 001331016 1/04/07 DA rough in on garage R125 02 2/20/07 BS ONE TRADE ROUGH IN VRU 001357243 2/20/07 DA 1.Need truss documents for garage trusses and garage girder truss nailing pattern.2. Cover floor upstairs in bath, set tub, cap tub drain and fill tub with water for drain connection test. 3. Install attic access ladder for unit. OK TO INSULATE. Recheck all items at insulation inspection R131 01 2/11/08 TI, a ONE TRADE FINAL VRU 001560622 PERMIT: CPER 00 CP ELECTRICAL RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS - E207 01 11/21/06 MR R*ELEC TEMP SERVICE POLE VRU 001311331 1 PREPARED 2/08/08, 14:06:07 INSPECTION TICKET PAGE 3 Harnett County INSPECTOR: IVR DATE 2/11/08 ADDRESS 422 CLARKS CORNER RD SUBDIV: CONTRACTOR PHONE OWNER WHIWE JEFFERY & ANGELA PHONE (919) 567-2042 PARCEL 05-0625- - -0100- - - APPL NUMBER: 06-50015002 CP MODULAR HOME REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R1251101 1/04/07 BS ONE TRADE ROUGH IN VRU 001331040 1/04/07 DA rough in up stairs no setup info or truss documents at jobsite. 2. Marriage lines covered before inspection (floor load beams for secondfloor loads at marriage line) 3. Rough ins called in but not ready. Tubs not set, fireblocking not done, no insulation baffles, etc. 4. Need truss engineeering for overframe supported on truss system. R125102 2/20/07 BS ONE TRADE ROUGH IN VRU 001357268 2/20/07 DA 1.Need truss documents for garage trusses and garage girder truss nailing pattern.2. Cover floor upstairs in bath, set j tub, cap tub drain and fill tub with water for drain connection test. 3. Install attic access ladder for unit. OK TO INSULATE. Recheck all items at insulation inspection R131 ~i01 2/11/08 T ONE TRADE FINAL VRU 001560655 PERMIT= CPPR 00 CP PLUMBING RESIDENTIAL REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS R12501 1/04/07 BS ONE TRADE ROUGH IN VRU 001331057 1/04/07 DA rough in up stairs 1 no setup info or truss documents at jobsite. 2. Marriage lines covered before inspection (floor load beams for secondfloor loads at marriage line) 3. Rough ins called in but not ready. Tubs not set, fireblocking not done, no insulation baffles, etc. 4. Need truss engineeering for overframe supported on truss system. R125I02 2/20/07 BS ONE TRADE ROUGH IN VRU 001357250 2/20/07 DA 1.Need truss documents for garage trusses and garage girder truss nailing pattern.2. Cover floor upstairs in bath, set tub, cap tub drain and fill tub with water for drain connection test. 3. Install attic access ladder for. unit. OK TO INSULATE. Recheck all items at insulation inspection R131 01 2/11/08 ~~TT~~t ONE TRADE FINAL VRU 001560663 COMMENTS AND NOTES ~G rZUd lG~,~Z,~ I 7 S~ 0 COUNTY OF HARNETT DEPARTMENT OF BUILDING INSPECTION AND PLANNING/DEVELOPMENT CERTIFICATE OF OCCUPANCY This certificate issued pursuant to the requirements of Section 105 of the North Carolina State Building Code and the Harnett County Zoning Ordinance certifies at the time of issuance this structure was in compliance with the various ordinances of the County of Harnett regulating development and building construction or use. For the following: • Use Classification: _ )F ) Conditional Use Permit No.: " N" Type of Construction: 1140iU,6 'i Building Permit No.: Owner of Building: i i/l & n, Electrical Permit No. v i Building Address: Insulation Permit No.: r Zoning District: j Plumbing Permit No.: Zoning Permit No.: i ✓ Mech. Permit No.: at/e: Envir. C.O. No.: Building Official Hrntfrtg_fl[fi l ' „flB1~ 114 W P$s~'W ~r win N~~I k 2-4, 1