Loading...
FM REVIEW Harnett { Y Emorgasuy Sexvnces 6apasimartt . x+xw.dtaaroatt.wp Plan Review, Inspection and Permit Fees Application Number 09-50021949 $100.00 ❑ Explosive Materials (90 Days) $ 35.00 ❑ Explosive Materials (48 Hrs) $ 25.00 ❑ Fireworks Public Display $ 20.00 ® Final Inspection $ 25.00 ❑ Fire Alarm Testing $ 25.00 ❑ Fixed Fire Suppression $ 10.00 ❑ Insecticide Fog/Fumigation $ 50.00 ❑ Testing of Pipes/UST/AGST $ 50.00 ❑ Plans up to 5000 ft2 $100.00 ❑ Plans 5001 ft2 to 10,000 ft2 $150.00 ❑ Plans 10,001 ft2 to 25,000 ft2 $250.00 ❑ Plans 25,001 ft2 and over $ 25.00 ❑ Sprinkler Certification Test $ 25.00 ❑ Standpipe Testing $ 25.00 ❑ Special Assembly $ 10.00 ❑ Temporary Kiosks/Displays $ 10.00 ❑ Tents greater than 700 ft2 $ 50.00 ❑ Tank Installation (charge for each tank) $ 50.00 ❑ Tank Removal (charge for each tank) $ 20.00 Total Teddy Joe McLamb 5/7/09 Code Enforcement Official Date Harnett C 0 U N T Y @mmazgmcySarviwa Dapartmnnt wwsv-.fiatnatt.mg Fire Marshal Division May 5, 2009 Daren McLean P.O. Box 1029 Lillington, NC 27546 Overhills Middle School 2711 Ray Rd Spring Lake, NC 28390 Application Number 08-50021949 Mr. McLean, Thank you for submitting the plans for the pod. The plans have been carefully reviewed by a qualified code enforcement official to examine for full compliance with the North Carolina Fire Prevention Code and all other fire protection regulatory documents. There are some items that were found during the plan review process that need to be addressed before a final inspection of the new facility can be given. These items are outlined and described below. e 1003.2.11 Means of egress illumination. o The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied o Bathrooms to have emergency lights installed. 1003.2.11.1 Illumination level o The means of egress illumination level shall not be less than 1 foot-candle (11 lux) at the floor level • 1003.2.11.2 Illumination emergency power c The power supply for means of egress illumination shall normally be provided by the premise's electrical supply. Harnett s Department 0 U N T Y Ema gmicy 3•rvk* *-A-(* wwNAarnwtt,org o In the event of power supply failure, an emergency system shall automatically illuminate all of the following areas: o Exit access corridors, passageways, and aisles in rooms and spaces which require two or more means of egress. o Exit access corridors and exit stairways located in buildings required to have two or more exits. o Interior exit discharge elements, as permitted in Section 1006. 1, in buildings required to have two or more exits. o The portion of the exterior exit discharge immediately adjacent to exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 604. • 906.1 Fire Extinguishers o Fire extinguishers shall be placed in approved locations as drawn by the code enforcement official on the approved plans. o The fire extinguishers provided shall have a minimum rating of 2A 5B:C and shall not be installed higher than 5 feet above the finished floor. • 404.2 Fire Safety and Evacuation Plans o An approved fire safety and evacuation plans shall be prepared and maintained for Group E occupancies. 907.1.1 Fire Alarm Construction documents o Construction documents for fire alarm systems shall be submitted for review and approval prior to system installation. The submittal shall be stamped/sealed by a design P.E. as per previous conversations. Construction documents shall include, but not be limited to, all of the following: • A floor plan. • Locations of alarm-initiating and notification appliances. • Alarm control and trouble signaling equipment. • Annunciation. • Power connection. • Battery calculations. • Conductor type and sizes. • Voltage drop calculations. • Manufacturers, model numbers and listing information for equipment, devices and materials. • Details of ceiling height and construction. • The interface of fire safety control functions. Harnett C 0 V T Emargansy4arvrwsDepartment hfm ~ e!.•. kOfi'i O CAAf•i3Nt. wwwJmrnatt.wg a 703.1 Fire Rated Construction o Protect all penetrations in the rated corridor. Thank you again for submitting the plans for the pod. Please review the plans and adhere to any notes and alterations that were made in addition to the original drawings. These remarks are for the plans that were submitted and its original intent. These remarks do not apply if the original intent changes or what was submitted on the above date changes. If you have any questions, please do not hesitate to call this office Again, thank you and we look forward to working with you during the construction period! Sincerely, T.J. McLamb, CFI Chief Deputy Fire Marshal