Loading...
IPAC RHTE# /O-S- aSo~~ Harnett County Department of Public Health Improvement Permit 26768 A building permit cannot be issued with only an Improvement Permit PROPERTY LOCATION: W r ISSUED T}• sgy y ~7 ° r>1ej SUBDIVISION LOT # NEW Cif REPAIR ❑ EXPANSION ❑ Site Improvements required prior to Construction Authorization Issuance: Type of Structure: _5"rb V 3 X 15- 6t Proposed Wastewater System Type: r~ S" 7, Projected Daily Flow: F 0 GPD Number of bedrooms:- Number of Occupants: max Basement ❑Yes LNo Pump Required: ❑Yes I N ❑ be required based on final location and elevations of facilities Type of Water Supply: ❑ Community MaPublic ❑ Well Distance from well feet Permit valid for: 2 Five years Permit conditions: ❑ No expiration Authorized State Agent:: / ci*' X el(I Date: 114 S~~~olf SEE ATTACHED SITE SKETCH The issuance of this permit bya Health Department in no way guarantees the issuance of other permits. The permit holder is responsible for checking with appropriate governing bodies in meeting their requirements. This site is subject to revocation if the site plan, plat, or the intended use changes. The Improvement Permit shall not be affected by a change in ownership of the site. This permit is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to conditions of this permit.. Construction Authorization (Required for Building Permit) The construction and installation requirements of Rules .1950, .1952, .1954, .1955, .1956, .1 9S7, .1958. and .1959 are incorporated by references into this permit and shall be met. Systems shall be installed in accordance with the attached system layout. ISSUED TO: - 5_` _Vtj y /4 o M ef° PROPERTY LOCATION: SUBDIVISION k" 6,A F.-f-^r LOT # 5- Facility Type: New ❑ Expansion ❑ Repair Basement? ❑ Yes Fzr No Basement Fixtures? ❑ Yes ❑ No Type of Wastewater System** a S 7, ked a e\ r~_ (Initial) Wastewater Flow: GPD (See note below, if applicable Ivl) .2-5-7- P-_ (Repair) Installation Requirements/Conditions Number of trenches Septic Tank Size /000 gallons Exact length of each trench Cl feet Pump Tank Size gallons Trenches shall be installed on contour at a Maximum Trench Depth of: % `ti - 30 inches (Trench bottoms shall be level to +/-1/4" in all directions) Pump Requirements: ft. TDH vs. GPM Conditions: Trench Spacing: 9 Feet on Center Soil Cover: C - /2, inches (Maximum soil cover shall not exceed 36" above the trench bottom) inches below pipe Aggregate Depth: inches above pipe inches total WATER LINES (INCLUDING IRRIGATION) MUST BE LOFT. FROM ANY PART OF SEPTIC SYSTEM OR REPAIR AREA. NO UTILITIES ALLOWED IN INITIAL OR REPAIR DRAIN FIELD AREA. **If applicable: /under fond the system type specified is different from the type specified on the application. / accept the speciTcationr of this permit. Owner/Legal Representative Signature: Date: This Construction Authorization is subiect to revocation if the site plan, olat. or the intended use changes. The Construction Authorization shall not be transferred when there is a change in ownershia of the site. This Construction Authorization is subject to compliance with the provisions of the Laws and Rules for Sewage Treatment and Disposal and to the conditions of this permit SEE ATTACHED SITE SKETCH Authorized State Agent: Zf"!::- "eC ffv Date: 7 dot, Construction Authorization Expiration Date: l ct6 HTE# /o-S =a5"0 f- Permit # 0`2\-'-I '6 Harnett County Department of Public Health Site Sketch t/ PROPERTY LOCATON: r, Q ISSUED T0: ~ v Yy ft C SUBDIVISION A k s- F C-211 LOT # J Authorized State Agent: Z.1~ , ~t~ Date: /l 1,12- 0/ (~MM0.. bur Department of Environment, Health and Natural Resources Division of Environmental Health On-Site Wastewater Section SOIL/SITE EVALUATION for ON-SITE WASTEWATER SYSTEM Owner: Applicant: /7! Address: Date Evaluated. ! o / Proposed Facility: Design Flow (.1949): Location of Site: Property Recorded: Water Supply: Q ublic❑ Individual ❑ Well Evaluation Method: ❑ Auger Boring ❑ Pit ❑ Cut Type of Wastewater: Sewage ❑ Industrial Process Sheet: Property ID: Lot File Code: Property Size: ❑ Spring ❑ Mixed ❑ Other P R 0 F I L 1940 SOIL MORPHOLOGY .1941 OTHER PROFILE FACTORS E # Landscape Horizon Position Depth Slope % (In.) 1941 Structure/ Texture .1941 Consistence Mineralogy .1942 Soil Wetness/ Color .1943 Soil Depth IN. .1956 Sapro Class .1944 Restr Horiz Profile Class & LTAR Lis -26 ze- Description Initial S stem Repair System Other Factors (.1946): Site Classification (.1948): Available Space .1945) Evaluated By: System T e(s) I d Others Present: ri L Site LTAR S~ , / .